Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.

Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. DLead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ For details about auto switches with pre-wired connector, refer to pages 1648 and 1649.

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ In addition to the models in the above table, there are some other auto switches that are applicable.

Direct mounting Rail mounting Load voltage Indicator light Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 12, 16, 32 to 63 20 to 63 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit A96V A96 A76H Reed switch Solid state switch A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV A93

mounting Bottom mounting Application Example Assembly lines, inspection lines etc. with turning operations Front mounting Side mounting Series Variations Bearing type Bore size (mm) Standard stroke (mm) Model Slide bearing MGTM 63 80 25, 50, 75, 100, 125, 150, 175, 200 Ball bushing bearing MGTL 100 8-24-2 3 Cylinder with Turntable Series MGT 63, 80 100 How to Order MX MTS M 63 50 11 Y59A S S A93

Lead wire length (m) Load voltage Indicator light Special function Wiring (Output) Electrical entry Type Applicable load Auto switch model 0.5 (Nil) 3 (L) 5 (Z) DC AC A90 IC circuit No 100 V or less 5 V, 12 V Reed switch Relay, PLC 2-wire 24 V Grommet A93 Yes 100 V 12 V M9N 3-wire (NPN) IC circuit Solid state switch 5 V, 12 V Relay, PLC M9P Grommet 3-wire (PNP) 24 V Yes M9B 2-wire

Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) Y59BL 5 m Z (Example) F9NWZ Since there are other applicable auto switches than listed, refer to page 8-15-44 for details.

Load voltage Internal voltage drop (illuminated load current load when ON) range AC DC 24V or less 50mA Relay D-A90 AC DC 48V or less 40mA Not provided PLC D-A90V IC circuit AC DC 100V or less 20mA D-A93 2.4V or less (up to 20mA) 3V or less DC24V 5 to 40mA D-A93 Provided Relay (up to 40mA) D-A93V PLC D-A93V 2.7V or less AC100V 5 to 20mA 2.7V or less D-A96 D-A96V DC4 to 8V 20mA 0.8V or less

Applicable model: D-A93 4. Mount a switch at the center of the operating range. 1) If connections are reversed on a 2-wire type switch, the switch will not be damaged if protected by a protection circuit, but the switch will be in a normally ON state.

Standard stroke 12 16 20 25 How to Order . 1 5, 10, 15, 20, 25, 30 5, 10, 15, 20 25, 30, 35, 40, 45, 50 Note 1) Single Rod Double Rod Return/Extend Single Rod Accessories . 5 Long stroke 12 16 20 Double Acting Single Acting Double Acting 35, 40, 45, 50, 75, 100 75, 100, 125, 150 175, 200 75, 100, 125, 150 175, 200, 250, 300 Construction . 6 25 Dimensions . 7 & 8 Reed switch D-A90, A90V D-A93

B Reverse the mounting direction A Reed switch D-A90(V), D-A93(V), D-A96(A) mm Auto switch mounting Switch operating range Stroke (mm) 20 45 25 51 31 Type 25 50.5 30.5 30 59 39 10 35 15 40.5 20.5 Caution A B A B A B MXP10 Tool for auto switch mounting MXP12 5 Use the screwdriver with grip diameter 5 to 6 mm when set screw (attached to auto switch) is set.

24V With Grommet Diagnosis indication (2-Color indicaiton) 12V F9NWV F9NW 3-wire (NPN) F9PWV F9PW 3-wire (PNP) F9BWV F9BW 2-wire PLC: Programable logic controller Lead wire length 0.5m " " (Example)A93 3 m " L " A93L Refer to page 177 to 179 for additional information on auto switches.

Load voltage Indicator light Lead wire length (m) AC DC Auto switch model Applicable load Pre-wire connector Special function Type Electrical entry Wiring (Output) 5(Z) 0.5(Nil) 3(L) Perpendicular In-line Reed switch Solid state switch IC circuit 3-wire (NPN equivalent) A96 A96 5 V Grommet Yes Relay, PLC 2-wire A93V A93 100 V 24 V 12 V M9NV M9N 3-wire (NPN) IC circuit 5 V, 12 V M9PV

For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with an

For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with an

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 63MM MYC/MY1C DBL-ACT AUTO-SW, ACTUATOR, MYC GUIDED CYLINDER, PE, 63MM MYC/MY1C DBL-ACT AUTO-SW, 46.29707 lb

For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with an

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 16MM MY1M DBL ACTING, ACTUATOR, MY1M GUIDED CYLINDER, GE, 16MM MY1M DBL ACTING, 7.61476 lb