SMC Corporation of America
Elite Part Number Search
Search Results "PF3W711-10-C-M"

The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.

The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.

D U 25 Approx. 44 R C C R G1/2 E E G1/2 B B 2-P Port size A A D 2-P Port size (S) Port size G1/2 Compatible heavy duty cord Cable O.D. 6.8 to 10 L L K 2-M Thread depth 6 K 2-M Thread depth 6 (mm) Electrical entry P Port size B C Model A D E F K L M Grommet: G Conduit: C DIN connector: D Conduit terminal: T U 81 91.5 101 103.5 Q 98 101 104 104 R 36 44 53 55.5 S 68 71 74 74 Q 46 50 52 52 R

Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.

Example) Assume circuit C with an operating pressure of 0.5 MPa, load weight of 10 kg, fluctuation to 20 kg and a cylinder bore of 32 mm.

effective thread depth 8 10 (11) Rod end male threads M M 48 24.5 D D 10 10 2-5.5 through 4-9 counter bore depth 7 36 36 8 20 2-Rc 1/8 (port size) 20 57 + Stroke 5 5 + Stroke 67 + 2 strokes C X L C X L + Stroke 47 32 to 100 2-P (port size) Approx.

Mounting style (CR): Head side clevis with ball joint A B C D EN ER F E L M N P H Bore size (mm) 0.2 max 0.2 H7 0.1 max H11 H13 H13 0.5 0.5 32 22 10 14 15 30 5 32.5 10.5 6.6 45 10.5 5.5 40 38 12 25 12 16 18 35 5 6.6 55 11 5.5 50 46.5 15 27 16 21 20 40 5 51 9 65 15 6.5 63 56.5 15 32 16 21 23 45 5 9 75 15 6.5 80 72 18 36 20 25 27 45 5 11 95 18 10 100 89 18 41 20 25 30 55 11 115 18 10 5

with ball joint A B C D EN ER F E L M N P H Bore size (mm) 0.2 max 0.2 H7 0.1 max H11 H13 H13 0.5 0.5 32 22 10 14 15 30 5 32.5 10.5 6.6 45 10.5 5.5 40 38 12 25 12 16 18 35 5 6.6 55 11 5.5 50 46.5 15 27 16 21 20 40 5 51 9 65 15 6.5 63 56.5 15 32 16 21 23 45 5 9 75 15 6.5 80 72 18 36 20 25 27 45 5 11 95 18 10 100 89 18 41 20 25 30 55 11 115 18 10 5 6-13-11 11 Series CP95 Dimensions: Cylinder

Series ANB1 38 dB (A) 30 m Page 5-10-9 Exhaust cleaner Ensures clean plant air, reduces noise pollution by over 35 dB (A), and removes over 99.9% of all oil mist. 99.9% Series AMC Page 5-10-11 35 dB (A) 0.3 m Page 5-10-13 Precautions/Specific Product Precautions Exhaust Cleaner for Vaccum (Series AMV) Exhaust Cleaner for Clean Room (Series AMP) Page 5-10-15 Related Products 5-10-1 2 Silencer

I-MU02 I-MU03 I-MU04 I-MU05 R1 3 4 5 6 NZ 18 22 26 32 NX 9 11 13 16 NO 21 24 27 39 NL 8 10 10 16 R1 8.5 10 11 16 NDH10 NL 8.5 10 11 16 NX 9 11 13 16 NO 19.5 24 26 36 U1 11 14 15 20 U1 13 14 17 23 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 Knuckle pin and snap ring are included. Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no.

F: Angle adjustment range 5 E: Angle adjustment range 5 E: Angle adjustment range 5 B port Angle adjustment screw A port Clockwise rotation 0 8 0 e Allowable Lateral Load to the Piston Rod End gl 10 n a e nt gl e an m st t en u dj m a m st u ju m i in ad M Using friction fittings makes it easier to mount the load to the piston rod end.

24V (1) C 24V 0V (4) DC24V 0V (1)(DC24V) (2)BK RLS (3)BK RLS -26- 6.4 (1)() (3m) SI PWR (3) EMG (2) M 24V (1) C 24V 0V (4) DC24V 0V -27- (2)((1)) DC24V EMG () DC24V 0V Ry Ry: U LK RLS (6) Ry (1 ) (3) EMG (2) M 24V (1) C 24V 0V (4) DC24V 0V LK RLS (6) Ry (2 ) (3) EMG (2) M 24V (1) C 24V 0V (4) DC24V 0V LK RLS (6) Ry (3 ) (3) EMG (2) M 24V (1) C 24V 0V (4) DC24V 0V

EXW1 EXW1 Up to 100 m V.1.0 / V.2.0 Available *1 EXW1 EXW1+EX600 *2 V.1.0 Not available EXW1 EX600 Up to 10 m V.1.0 Not available EX600 EXW1 Up to 10 m V.1.0 Not available Available *3 EX600 EXW1+EX600 Up to 10 m V.1.0 Not available Available *3 EX600 EX600 Up to 10 m V.1.0 Not available Available *1 Available in protocol V.2.0. *2 Up to 100 m between an EXW1-series Base and Remote, and up

Model r e b m u N A f o t r o P l e d o M g n i t r o P e z i s t r o P B e z i s t r o P A c i r t e M " 2 3 / 5 " 4 " 4 / 1 " 6 " 6 1 / 5 " 8 t r o P A t r o P B h c n I 1 1 M K h c u o t e n O g n i t t i f g n i t t i f h c u o t e n O 0 1 , 6 6 1 / 5 8 8 / 3 0 1 2 / 1 2 1 2 1 M K h c u o t e n O g n i t t i f d a e r h t T P N 0 1 , 6 4 / 1 T P N ) T P ( c R 4 / 1 d a e r h

plug connector (M) 0.45 0.6 (Option) 100V AC 200V AC 110V AC 220V AC (A) 2 VQ M plug connector (M) VQZ 1 (P) 3 (R) N.O.

MY2 H/HT MY3A MY3B m (800) MY3M 50 L (600) 40 m L 30 MY1H40 (550) Mass m (kg) m MY1H32 20 L L MY1H25 10 Caution 1. If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Therefore, be sure to level the cylinder tube when mounting it.

Static moment M2 = WL1 = 100.2 = 2 [Nm] 2 = M2/M2 max = 2/16 = 0.125 W = 1 [kg] = 10 [N] W Review M2. Since M1 & M3 are not generated, review is unnecessary. M L1 3. Dynamic moment We = 5 x 10-3WgU = 5 x 10-31.9.8500 = 25 [N ] Me3 = 1/3We(L2-A) = 1/3250.182 = 1.52 [Nm] 3 = Me3/Me3max = 1.52/6 = 0.25 Me3 Review Me3. (For Memax, find the value in when U = 500mm/s.)

Bracket A Bracket B/C Clip One-touch fitting Bracket B Mounting example Lead wire Added the connector cover. Connector cover Mounting example Lead wire with connector (2 m) Bracket C Mounting example Panel mount Mountable side by side without clearance 4-digit display 4-digit display allows easy reading of displayed values. Example: 0.5 MPa One opening!

If the discharge pressure is required instead of the total lifting height, a total lift of 10 m corresponds to a discharge pressure of 0.1 MPa. Selection procedure: 1. First mark the intersection point for a discharge rate of 600 m l/min and a lifting range of 15 m. 2.