CDH10 U L CX CZ ZZ + Stroke Z + Stroke RR (mm) Stroke range Bore size (mm) U RR +0.3 +0.1 L CDH10 CX CZ Z ZZ 20 25 32 40 50 63 80 Up to 250 Up to 350 Up to 600 Up to 600 Up to 700 Up to 900 Up to 900 14 14 17 17 26 26 30 10 10 14 14 22 22 25 14 14 20 20 30 30 32 28 28 40 40 60 60 64 8.5 11 12 15 18 23 28 23 23 30 30 42 42 50 129 151 185 208 237 263 298 137.5 162 197 223 255 286 326 8-25-24
LEF D-M9NAV D-M9NA D-M9BA D-M9BAV D-M9PAV D-M9PA Auto switch model In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction LEJ 3-wire 2-wire Wiring type NPN PNP Output type LEL 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage LEM 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage
(Nominal size) Port size Hydraulic fluid Material 04 06 08 10 12 16 20 24 28 32 04 06 08 10 12 16 20 24 28 32 AL-128H AL-129H AL-131H AL-132H AL-134H AL-135H AL-136H AL-137H KA00813 (V120) AL-128H-V AL-129H-V AL-131H-V AL-132H-V AL-134H-V AL-135H-V AL-136H-V AL-137H-V KA00728 (V120) KA00815 (V85) KA00812 (V100) KA00813 (V120) KA00814 (V150) KA01800 (V175) KA00731 (V85) KA00727 (V100) KA00728
49 35 28 16.8 2.7 12 PF3W711 3/41 124 92 46 77 57.6 23 41 42 63 48 28 18 3.5 14 S T U V W WX Y Z PF3W704 24 22 32 40 50 4.5 5 1.5 PF3W720 28 22 32 40 50 4.5 5 1.5 PF3W740 34 30 42 48 58 4.5 5 1.5 PF3W711 44 36 48 58 70 5.5 7 2 -81No.PF-OMM0004-D PF3W721 A AA B D E F G H J K L N P 11/4,11/2 104 74 31 52 39.5 G 11/4 108 76 33 54 41.5 PF3W721 56 91 71.6 28.5 54 25 27.5 3.5 14 G 11/2 112 78
/IN (/15 V ) 3 DC() 4 INPUT (15 V ) COPY OUT2 OUT1 DC() DC() -16No.PF-OMN0011CN-C ,FG () SMC(1) ZS-28-CA-4() 1.151.35 ZS-28-C-1 1.01.2 AWG23 1.14ZS-28-CA-4 1 2 3 4 PF3W5 M8 A A ,LLL -17No.PF-OMN0011CN-C NPN2 PF3W30A PNP2 PF3W30B DC(+) DC(+) OUT1 OUT1 OUT2 OUT2 DC(-) DC(-) / / Max.28 V80 mA 1 V Max.80 mA 1.5 V NPN PF3W30C NPN PF3W30D PNP PF3W30E PNP PF3W30F
DC() OUT1 OUT2 DC() OUT1 OUT2 DC24V DC24V DC() DC() Max.28 V80 mA 1 V 420 mA 600 Max.28 V80 mA 1 V 15 V 1 k 22 No.LFE*-OMY0008 NPN2 LFEA NPN LFEC LFED OUT1 OUT2(LFE*A***) DC() DC() OUT1 PNP2 LFEB OUT2 OFF( 23 No.LFE*-OMY0008 1 3 (OFF) 1 1 ON OFF ON OFF [L/min [L/min [L/min [L/min] ] ] ] ON ON ON ON OFF OFF OFF OFF ( ( ( ( ) ) ) ) 24 No.LFE*-OMY0008 1 [P_1][n_1] 1
No.PS-OMU0002CN-D // ZSE20A(F) ISE20A 2 8 10 11 15 15 17 19 [] 22 23 3 24 26 28 28 28 F0 30 F1 OUT1 31 F2 OUT2 34 F3 36 F4 37 F5 FUNC 39 F6 41 F10 42 F11 48 F80 49 F81 50 F82 52 F90 53 F96 55 F97 56 F98 58 F99 60 61 65 65 66 75 75 78 -1No.PS-OMU0002CN-D 1 (ISO/IEC)(JIS) *1) *2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO
CY36 Consult with SMC in case a bracket with weight exceeding the above value is to be mounted. 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1000 2000 3000 4000 5000 6000 CY315 Note 1) According to the dead weight deflection in the figure on the right, provide clearance so that the cylinder does not touch the mounting surface or the load, etc., and is able
175, 200, 250, 300 25 Standard Non-rotating Rod Anti-lateral Load Reed switch D-A90/A90V D-A93/A93V D-A96/A96V Series CQSW 12 16 5, 10, 15, 20 25, 30 7-4-20 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 Series CQS 12, 16 20, 25 12 16 20 25 5, 10 7-4-12 Solid state switch D-M9N/M9NV D-M9P/M9PV D-M9B/M9BV D-F9NW/F9NWV D-F9PW/F9PWV D-F9BW/F9BWV D-F9BAL Series CQSK 12 16 5, 10, 15, 20 25, 30 7-4-28
M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.
(mm 2) (mm) SMC(1) 0.81.0 ZS-28-C 1.01.2 ZS-28-C-1 26-24 (28) 0.14-0.2 (0.08) 1.21.6 ZS-28-C-2 1.01.2 ZS-28-C-3 1.21.6 ZS-28-C-4 22-20 0.3-0.5 1.62.0 ZS-28-C-5 1 (DC+) 2 3 (DC-) 4 (IN15 V) A A -15No.PS-OMH0005CN-D No 8 7 CH4_OUT1 6 CH3_OUT1 5 CH2_OUT1 4 CH1_OUT2 3 CH1_OUT1 2 DC(-) 1 DC(+) -16No.PS-OMH0005CN-D ( ) ( ZS-26-A) PSE200-(M)NPN 5 +1 Max. 30 V80 mA 1 V DC(+) CH1_
IN(66) IN OUT OUT IN 8cm () Rc1/2NPT1/2Rc3/4NPT3/4 2830 Nm 1/2 30 mm 3/4 35 mm 9mm 2F.S. -16No.PF-OMP0001CN-F FG 1 DC(+) 2 OUT2// 3 OUT1 4 DC(-) -17No.PF-OMP0001CN-F NPN(2 ) PFMB7--ADC(+) OUT1 OUT2 DC(-) 28 V 80 mA 1 V NPN(1 )(15 V) PFMB7--CNPN(1 )(420 mA) PFMB7--DDC(+) OUT1 DC(-) 28 V 80 mA 1 V C15 V 1 k D420 mA 600 NPN(1 ) PFMB7--GDC(+) OUT1 DC(-) 28 V 80 mA 1 V 0.4V ()30 msec
49 35 28 16.8 2.7 12 PF3W511 3/41 124 92 46 62.6 57.6 23 41 42 63 48 28 18 3.5 14 S T U V W WX Y Z PF3W504 24 22 32 40 50 4.5 5 1.5 PF3W520 28 22 32 40 50 4.5 5 1.5 PF3W540 34 30 42 48 58 4.5 5 1.5 PF3W511 44 36 48 58 70 5.5 7 2 -41No.PF-OMN0009CN-F PF3W521 2X A AA B DD E F G H J K L N P 11/4,11/2 104 74 31 52 39.5 G 11/4 108 76 33 54 41.5 PF3W521 56 76.6 71.6 28.5 54 25 27.5 3.5 14 G 11
Size: 15 28 Cross recessed round head screw 2 27 Switch holder 2 26 Cross recessed round head screw 1 25 Hexagon socket set screw 1 24 Cross recessed round head screw 2 23 Cross recessed round head screw 2 22 Cross recessed round head screw 2 28 21 Holding block (B) 2 27 20 Holding block (A) 2 20 19 Magnet 1 18 Magnet lever 1 Including No.19 17 Switch block (B) 1 16 Switch block (A) 1
28 29 30 29 30 / 14 14 15 15 25 26 27 25 26 27 11 11 12 12 19 19 21 21 18 18 16 16 22 22 24 24 17 17 12 13 12 13 23 23 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 20 20 34 33 35 32 31 1 21 2 22 3 23 4 24 5 25 6 26 NBR 7 27 8 POM 28 9 29 10 30 11 31 12 32 13 33 14 34 15 35 NBR 16 17 18 101 19 POM 101 20 / 16 LEY-L016 LEY-F016 LEY-D016 16 LE-D-2-1 25
LEHS 4.1 LEHS10 LEHS20 LEHS32 LEHS40 / (mm) 4 6 8 12 (mm) 255/76 235/56 235/40 235/40 2.25.5 922 3690 52130 (N) 40100 1) 3) 1.43.5 717 /(mm/s) 2) 3) 570 /550 580 /550 5100 /550 5120 /550 (mm) 4) 0.02 (mm) 5) 0.05 /(mm) 6) 0.5 / (m/sec 2) 7) 150 30 (c.p.m) 60 () 540 (%RH) 90 () 185 410 975 1265 (g) 150 345 20 28 42 (DC24V) () A/B (800 /) (V) DC2410% 11/7 28/15 34/13 36/13 /
(Refer to specifications.) 28 Series CY3R Auto Switch Precautions 1 Be sure to read before handling. Design and Selection Warning 1. Confirm the specifications. In the same way, when operating below a specified voltage, although an auto switch may operate normally, the load may not operate.
GB H LB LC LH LT LX LY LZ MM NN NA NB S X Y Z 10 15 15 12 17 14 4 8 8 5 28 21.5 5.5 14 2.5 33 25 42 M4 x 0.7 M10 x 1.0 12.5 9.5 46 6 9 74 16 15 18 18 20 20 5 8 8 5 28 23 5.5 14 2.5 33 25 42 M5 x 0.8 M12 x 1.0 12.5 9.5 47 6 9 75 4 Series CJ5-S Dimensions R V Front flange type (F)/CJ5FS CA Rod cover side GB Piping port 2-M5 x 0.8 Piping port M5 x 0.8 GA NN MM Cover surface BA CB D FY FB 2
In-line In-line In-line Perpendicular Perpendicular Perpendicular Electrical entry direction 2-wire 3-wire Wiring type PNP NPN Output type 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage 10 mA or less Current consumption 28 VDC or less 24 VDC (10 to 28 VDC) Load voltage 2.5 to 40 mA Load current 40 mA or less 0.8 V or less 4 V
23 17 1 4 3 8 KAH10-U02 KAH10-U03 22 18 17 10 17 21 29.5 29.5 24 14 1 2 KAH10-U04 22 14 28 22 16 22 1 4 3 8 KAH12-U02 KAH12-U03 24.5 19.5 30.5 25.5 19 12 19 22 46.1 46.1 1 2 KAH12-U04 24.5 16.5 22 28 Reference dimensions after Uni thread installation.