Re-attach the cover or real panel after wiring is done. 118 to 138 mil 3 to 3.5mm IDFB22E, 37E PE Screwdriver entry Cable entry Terminal block Applicable screwdriver IDFB55E, 75E Earth terminal block 118 to 138 mil 3 to 3.5mm Screw = M410 Earth cable connection L1 L2 L3 Screwdriver entry Cable entry Terminal block Applicable screwdriver IDFB Series 2-2Installation 2 5 IDX-OM-W034 Air Dryer
3 122 F(50) 122 F(50) OUT IN (IN) (OUT) 2 2 4 10mm(3/8inch) IDFB Series 2-2 2-2 IDX-OM-W035 2 2 2 5 6-1 IEC ) [ 30mA IDFB22E,37E 15AIDFB55E, 75E 10A] 2) 0.3inch0.5inch (812mm) 16AWG (1.25mm IDFB22E, 37E 3 IDFB55E, 75E 4 4inch (0.1m) 98feet (30m) (3/8 10mm) IDFB Series 2-2 2-3 IDX-OM-W035 2 IDFB22E/37E 118138 mil (33.5mm) PE IDFB55E/75E 118138 mil (33.5mm) =M4X10 L1 L2
number for each respective tube bore size. 6-12-6 Series C95 ISO/VDMA Cylinder: Standard Type Double Acting, Single/Double Rod Dimensions: Without Mounting Bracket [First angle projection] C95SB Bore size Stroke CJ1 CJP CJ2 CM2 CG1 MB MB1 CA2 CS1 C76 C85 C95SB Bore size Stroke W C95 CP95 NCM NCA D-X 20Data Bore size (mm) B e11 E R AM D EE PL RT L12 KK SW G BG (MIN) L8 VD VA WA WB WH ZZ ZY L2
UNF Weight (g) 10-32 UNF D1 D2 L2 A L1 Nylon Urethane KSL03-34S KSL03-32 8 10-32 UNF 9 14 17 23 23 29 56 64 20.5 22 22 23.5 23 25.5 26 26.5 5 32 16 2.5 10.4 3.5 3.5 12 21 1 8 12.7 1 8 1 4 KSL07-34S 14.29 17 1 4 4 13.2 8.6 8.6 23.5 14 KSL07-35S KSL09-34S KSL09-35S KSL11-35S KSL11-36S 1 8 26.5 30 18.5 5 16 1 4 1 4 3 8 21.6 14.9 6 15.2 17.46 26 17 29.5 31 34 37 35 38 22.23 3 8 30.5 25.0 7 17.9
Nylon Urethane L1 L2 M 1 4 1 4 3 8 3 8 3 8 KCE04-02 KCE06-02 KCE08-03 KCE10-03 KCE12-03 2.6 32 36 42 79 105 2.6 6.8 16.2 25.6 35.4 M12 1 M14 1 M16 1 M20 1 M22 1 40.5 42.7 49.4 53.9 56.1 14 17 19 24 27 17 17 19 22 24 14.7 14.7 15 14.2 13.7 13 15 17 21 23 18 19 21.5 24 25.5 6.8 13.1 20.4 30.4 Straight: KCH Applicable tube O.D.
Description Material AS800 AS900 6 7 8 O-ring O-ring Spring NBR NBR Stainless steel KA00069 KA00460 14115 KA00072 KA00462 14124 ASN AQ ASV Dimensions: AS420/500/600 Dimensions: AS800/900 AK VCHC ASR ASQ 2 x Port size 2 x Port size L3 L2 L1 D Dimensions L1 L2 D Min. L3 (1) Model Port size Max.
L Plate cylinder type with small auto switch CLKG CKQ CLKQ Small auto switch CK CLK CK CLK L29 mm width L Guide pins and a diamond shape option (available for 10 or more) for workpieces with 9, 11 and 13 hole diameters CKQ 29 mm L2 types of clamping heights can be selected.
-L1) Width at closing (mm) (L1) Width at opening (mm) (L2) Weight (g) Model 112211221122112211221122112211221122112211221122112211221122112211221122MHL2-10D MHL2-10D1 MHL2-10D2 MHL2-16D MHL2-16D1 60 72 94 112 84 126 92 134 172 114 186 340 405 485 660 870 20 40 60 30 60 10 40 60 L1 16 40 L2 MHL2-16D2 MHL2-20D MHL2-20D1 MHL2-20D2 MHL2-25D 146 98 158 178 116 226 138 238 278 166 1010 1175 1645
5.25 5.5 8 16.5 16.5 27 16.5 10.5 L3 : Manifold overall length L2 : Mounting screw length L1 : Rail overall length 1098 Series ZYY/ZYX Electronic Pressure Switches Specific Product Precautions 1 Be sure to read before handling.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB MB1 CA2 CS1 C76 C85 C95SB Bore size Stroke W C95 CP95 NCM NCA D-X 20Data Bore size (mm) B e11 E R BG (MIN) AM D EE PL RT L12 KK SW G L8 VD VA WA WB WH ZZ ZY L2 L9 22 24 32 32 40 40 30 35 40 45 45 55 12 16 20 20 25 30 G 1/8 G 1/4 G 1/4 G 3/8 G 3/8 G
HUMIDITY SENSOR. CONDENSATION CHECKER. 158.80000 lb. Q62.
HUMIDITY SWITCH, HUMIDITY SENSOR, Q62, 152.00000 lb
HUMIDITY SWITCH, HUMIDITY SENSOR, Q62, 157.80000 lb
HUMIDITY SWITCH, HUMIDITY SENSOR, Q62, 142.00000 lb
HUMIDITY SWITCH, HUMIDITY SENSOR, Q62, 152.00000 lb
L2 = 21 x m + 89.8 L1 = 10.5 x n + 45 Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Default settings At the time of factory shipment, the product is in "Remote Control Mode" and set to "Enable DHCP".
HRLE050 200V N L HRLE090 200V L3 L1 L2 Fig. 3-12 Cable wiring (200V) 3.3 Installation Procedure HRLE Series 3-16 HRX-OM-Z002 Chapter 3 Transport and Set Up 400V L1 L2 L3 Fig. 3-13 Cable wiring (400V) HRLE Series 3.3Installation Procedure 3-17 HRX-OM-Z002 Chapter 3 Transport and Set Up 3.3.4 Preparation and wiring of communication cable Be sure to turn OFF the breaker of the facility power
Dimensions C D L1 L2 Fd Fc C Fn (Fc) (KF Flange) (K Flange) (CF Flange) K B J H A G A Unit: mm Model A B C D Fn Fd Fc G H J KK P.C.D.
Dimensions XMH series / Angled Valve C D L1 L2 A Fn Fc C (Fc) (CF Flange) (KF Flange) H J H B G A Unit:mm Table 5 Model A B C D Fn Fc G H J P.C.D L1 L2 XMH-16 40 100.5 38 1 30 34 17 35 18 P.C.D 27 6x4.4 XMH-25 50 114 48 1 40 26 41 21.5 XMH-40 65 162.5 66 2 55 70 41 57 30 P.C.D 58.7 6x6.6 XMH-50 70 179.5 79 2 75 52 70 35 XYH series / Straight Valve D G C C B H Fn J (KF Flange) 45 Unit: mm
. 2. 3. 1. 2. 3. 4. 3 *3) 1 1.5 3) 1 1 () 4 1 1-1 MXQ6 MXQ8 MXQ12 MXQ16 MXQ20 MXQ25 1) 2) ( ) 3) 4) / / 2 ,3 ) 2 2 ,3 ) 1) 1 2) 20 ,0.150.6MPa 3) MXQ25(A)-150,MXQ6B-50,75MXQ8B-75,100MXQ16B-100,150MXQ20B-125,150 300mm/s 4) MXQ**B 50200mm/S 1 (MPa) MXQ8(A,C) 0.3 MXQ8B 0.3 MXQ12(A,C) 0.3 MXQ12B 0.3 MXQ16(A) 0.2 MXQ16B 0.2 MXQ20(A) 0.2 MXQ20B 0.2 MXQ25(A) 0.2 5 2. 2-1 ,2 L1 L2