A digital pressure gauge is recommended for such situation or as deemed necessary. 451 AR10-A to AR40-A Series Flow Rate Characteristics (Representative values) Condition: Inlet pressure 0.7 MPa AR10-A M5 AR20-A Rc1/4 0.6 0.6 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 0 25 50 75 100 125 150 0 200 400 600 800 Flow rate L/min (ANR) Flow rate L/min
Configuration 89 EDS file and icon 89 Setting using Logix DesignerTM 89 Configuration assembly 94 Parameter setting of EX600 with configuration assembly 94 Parameter setting of IO-Link device with configuration assembly 107 Configuration assembly setting method example 108 Device Level Ring (DLR) function 111 QuickConnectTM function 111 EtherNet/IPTM Object 113 IO-Link SMI service 120 Web Server 125
Model Port size Model Port size 120 150 AS800 AS900 1 1 , 2 74 93 204 262 192 250 80 94 AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 15-9-33
Because 2.5N < 48N. it is applicable. 30 20 18N 10 0 80 70 60 50 40 30 Because 2.1N < 18N, it is applicable. Point of application L (mm) Therefore select MIW (MIS) 12.
Because 2.5N < 48N. it is applicable. 30 20 18N 10 0 80 70 60 50 40 30 Because 2.1N < 18N, it is applicable. Point of application L (mm) Therefore select MIW (MIS) 12.
Rc 1/4 108 Head end cylinder port Rc 1/4 Dustproof cover Rod end cylinder port (Manual lock release) D (Stroke) Rc 1/8 Unlocking port IN OUT (125) (102) C B A Rc 1 DRAIN 195 (270) Dimensions (mm) A B C D Model Bore size (Nominal size B) FN111 FN112 610 (730) (844) 20 Rc 1 860 (1000) (1134) 40 8 Series FN1 Options Reservoir Dust removal filter 108 32 0 315 45 P.C.D.220 70 70 90 270 (80) 50
10 30 to 10 22.5 to 10 Angular gripper 180 opening/closing 88 to 5 54 to 6 58 to 5 41 to 5 30 to 4 Air cylinder Compact guide cylinder MGP 3.5 5 4.5 4.5 5.5 5.5 5.5 5.5 5.5 6 CA2 Air cylinder 4 4 6 6 6 Sensor unit D-F7K Air cylinder (mm) Model Bore size (mm) 12 4.5 16 20 25 32 40 50 63 80 100 125 7.5 140 7.5 160 CQ2 CM2 Compact cylinder 5.5 5.5 5 5.5 5.5 5.5 6 5.5 6 7.5 Air cylinder 3.5
Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
Note: The 24 VDC external power supply capacity must be 50 mA minimum. The DRIVERs input circuit uses bidirectional photocoupler. Select either the sink circuit or the source circuit according to the specifications required for each machine. Note: The connection example in 2.3 shows sink circuits.
1 . 8-1 8-2 . 8-1 9 R 9-1 . 9-1 9-2 . 9-1 9-3 . 9-1 10 S 10-1 . 10-1 10-2 . 10-1 11 T 11-1 . 11-1 11-2 . 11-1 11-3 . 11-1 11-4 . 11-2 11-5 . 11-3 12 V 12-1 . 12-1 12-2 . 12-1 12-3 . 12-2 13 13-1 . 13-1 IDFB Series 2 IDX-OM-W020 i i i 1 () OFF 3 ON OFF i 1 1 3 i-1 IDFB Series i 1 IDX-OM-W020 i i 2 5 i 2 1 i-2 IDFB Series i 2 IDX-OM-W020 i i 2 2 i 2 3 50
Bore size: 50, 80 mm; Stroke lengths: 25, 50, 75, 100, 125, 150, 175, 200 mm; Non-rotating accuracy of +/-0.05° (50 mm bore); Non-rotating accuracy of +/-0.04° (80 mm bore); Rubber bumpers as standard; Auto switch capable
Bore size: 50, 80 mm; Stroke lengths: 25, 50, 75, 100, 125, 150, 175, 200 mm; Non-rotating accuracy of +/-0.05° (50 mm bore); Non-rotating accuracy of +/-0.04° (80 mm bore); Rubber bumpers as standard; Auto switch capable
Pin Clamp Cylinder D series Series CKQ D/CLKQ D G P G P How to Order Built-in standard magnet With magnetic field resistant auto switch D A 50 177 R A L P4DWSC KQG C Built-in strong magnet With magnetic field resistant auto switch D A 50 198 R A L P79WSE C KQP With lock on the clamp side Number of auto switches L Nil Without lock With lock S Nil 2 pcs. 1 pc.
Thermo-chiller Dual Channel Refrigerated Thermo-chiller for Lasers HRL Series How to Order HRL A 20 100 Power supply Cooling capacity CH1 CH2 100 9 kW 1 kW 200 19 kW 1 kW 300 26 kW 1 kW 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) Pipe thread type Nil Rc F G (with Rc-G conversion tting) N NPT (with Rc-NPT conversion tting) Cooling method A Air-cooled refrigeration Specications
/60 Hz 50/60 Hz 50/60 Hz Maximum micro power cut 10ms 10ms 5ms 10ms 5ms Maximum inrush current 0.7A 1.5A 0.7A 1.5A 7A 0.7A 1.5A 7A Maximum power 3W 4W 3W 8W 6W consumption ANALOGUE INPUT CHARACTERISTICS AC INPUT CHARACTERISTICS 10 6 inputs from I01 to I06 Input voltage 100-240 VAC + 10% 15%, 20 8 inputs from I01 to I08 50-60 Hz Measurement range 0-255 Input impedance >or = 800 kOhms Resolution
Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
Square Tube Type Air Cylinder/Standard Type: Double Acting, Single Rod Series MB1 Replacement Procedure is 32, 40, 50, 63 80, 100, 125 P.284 Construction !6 !5 !8 !4 !7 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series MB1. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no.
Square Tube Type Air Cylinder/Standard Type: Double Acting, Double Rod Series MB1W 32, 40, 50 63, 80, 100 125 Replacement Procedure is P.284 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !4 !6 !3 !5 !
Seal kit includes a grease pack (32 to 50: 10 g, 63, 80: 20 g, 100, 125: 30 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) Model without air cushion is designed to include rubber bumpers. 29
Bit: 7 0 Byte 1 Offset Baud rate (Communication speed) (bit/s) 500 k 250 k 125 k 50 k 20 k 10 k 1 M 800 k Bit: 7 0 Byte 2 Offset Max. bus cable length (m) 25 50 100 250 500 1000 2000 5000 Power supply wiring Power supply connector Bit: 7 0 Byte 3 Offset M12 5-pin plug B-code (reverse) Bit No. 0 2 4 6 0 0 4 6 No. Description Function Output No.