Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 8-30-64
Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 8-30-64
Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 8-30-64
Seal Metal seal Rubber seal Coil voltage 0 1 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Function 1 2 3 Stations U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) D side (2) Note 1) Applicable to DC specifications. Note 2) Refer to page 2-5-39 for external pilot specification.
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
(mm) Proper tightening torque (Nm) Cylinder stroke (mm) Model 5 10 15 20 25 30 40 50 6, 10 16 20, 25 32 M3 M4 M5 M6 1.08 10% 2.45 10% 5.10 10% 8.04 10% 22 (27) 25 (35) 28 (38) 31 (41) 34 (44) 37 (47) C(D)U6-D 36 (41) 40 (50) 44 (54) 48 (58) 52 (62) 56 (66) C(D)U10-D 50 (75) 56 (86) 62 (92) 68 (98) 74 (104) 80 (110) C(D)U16-D 95 (128) 106 (143) 117 (154) 128 (165) 139 (176) 150 (187)
With feet and no rack mounting brackets With flow switch High-pressure pump mounted HECR 008-A 800 W 1.4 kW Tap water 0.01 to 0.03C Ethylene glycol 20% 010-A 1 kW 2 kW Single-phase 200 to 240 VAC (50/60 Hz) (UL Standards) Water-cooled Single-phase 100 to 240 VAC (50/60 Hz) New New HECR 008-W 800 W 1.4 kW Peltiertype watercooled 012-W 1.2 kW 2 kW Single-phase 200 to 240 VAC (50/
Standard Strokes Bore sizes (mm) Standard strokes (mm) 20, 25 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 32 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75 40, 50, 63, 80, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Made to Order Hydraulic Fluid Compatibility Manufacture of Intermediate Stroke Cylinders Pages 10 to 12 Intermediate strokes in 5mm increments can be manufactured by installing spacers
VN Solenoid valve option Nil Standard Rated voltage 1 2 3 4 5 6 7 8 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) LVC Select an option mark in page 17-3-9 by Applicable Fluids Check List for special fluids outside of the standard.
58 0 254 3/8 187 334 31 M18 x 1.5 stroke 80 12.5 65 372 71 0 284 1/2 205 37 381 M22 x 1.5 81 14 65 389 72 0 300 1/2 214 398 40 M26 x 1.5 Foot style LS + Stroke ZZ + Stroke LD ZZ Y X LX LS LH B Bore size (mm) 40 50 63 80 100 9 309.5 13 27 42 272.5 40 58.5 9 333.5 13 27 50 289.5 45 68.5 11.5 362 16 34 59 322 50 83 13.5 415 16 44 76 372 65 100 13.5 432 17 43 92 386 75 114 10-12-50 8 Stroke
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.
Lateral load F = mg [N] (g: Gravitational acceleration = 9.8 [m/s2]) Mass of transferred object m [kg] RSQ RSG Friction coefficient RS2H RS2H RSH P: Operating pressure of the cylinder [MPa] MIW MIS D-X 593 Heavy Duty Stopper Cylinder 50, 63, 80 RS2H Series RoHS How to Order D 30 RS2H 50 L M9BW Bore size 50 63 80 50 mm Port thread type Number of auto switches (auto switch number mounted)
Applicable bore size (mm) Cylinder series 32 40 50 63 80 100 MDB1 BMP1-032 7-9-48
[mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ion silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Not detected Not detected Referential Ammonium ion [mg/L] 0.1 or less 1.0 or less item Residual chlorine [mg/L] 0.3 or less 0.3 or less Separation carbonic acid [mg/L] 4.0 or less
VX3 Rated voltage 1 2 3 4 5 6 7 8 9 Valve/Body 0 Normally cosed/Single unit 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 48 VAC 50/60 Hz Other (Please contact SMC separately.) VXA VN Solenoid valve option Nil Standard LVC Select an option mark in page 17-3-11 by Applicable Fluids Check List for special fluids outside of the standard.
VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Electrical entry: D or DZ only Electrical entry: D or DZ only Coil rated voltage 1 2 3 Note 1) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 4 Note 1) Manual override 5 6 Note 1) Non-locking push type Nil A Electrical entry CE-compliant G Non-locking push type
[mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ion silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Not detected Not detected Referential Ammonium ion [mg/L] 0.1 or less 1.0 or less item Residual chlorine [mg/L] 0.3 or less 0.3 or less Separation carbonic acid [mg/L] 4.0 or less
VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other 1 2 3 4 5 6 7 9 Coil rated voltage 1 2 3 4 5 6 7 9 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Other Electrical entry G C TNote) D DL Option Electrical entry/With indicator light/ surge voltage suppressor Grommet Conduit Conduit terminal DIN terminal DIN terminal with