B (9.5) B (12.7) B (19.1) B (25.4) B (31.8) B (38.1) B (50.8) VNA 111 211 311 411 511 611 711 AS 420-03 420-04 500-06 600-10 800-12 900-14 900-20 3 8 1 2 3 4 10A 15A 20A 25A 32A 40A 50A 1 2 VNA01 VNA02 VNA03 VNA1 Port 12 (P1) 1 1 1 2 External pilot External pilot External pilot External pilot External pilot Pilot exhaust Bleed port Bleed port 1 4 1 2 10 (P2) Installing a silencer to the
0 C +0.5 0 4-Rc 1/4, 3/8 4 (B) B 0.1 Max. panel thickness D (mm) A 3.2 3.2 3.2 Model B 40 51 64 C 35 41 51 D 3.5 6 8 VH200 VH300 VH400 3.6-12 Series VH Panel Mounted/Dimensions VH41l-02 to 04 VH41l-06 2 (A) 4 (B) 4 (B) 2 (A) 25 25 3 (R) 1 (P) 3 (R) 1 (P) 107.5 19 l102 102 89 88 4-6.6 4-6.6 88 81 94 148 144 97 97 67 1.5 65 1.5 125 123 105.5 3 (R) 3 (R) 1 (P) 1 (P) 25 17 2 4-Rc1/4, 3/
VHS20 to 50-A . ; . ; Built-in silencer (Option) = = @ @ 2 1 (IN) 2 (OUT) IN OUT B B : : Cross section of EXH port > > 3 (EXH) EXH Option Part No.
A Formula for Obtaining the Set-Value P-1 P_1 or P_2 H_1 or H_2 H-1 P_1 (P_2) = A (A-B)/4 n_1 (n_2) = B + (A-B)/4 H_1 (H_2) = | (A-B)/2| n-1 Min. B Released Work 1 Work 2 Work n D Peak/Bottom value indication Atmosphere This function constantly detects and updates the maximum (minimum) value and allows to hold the maximum (minimum) pressure value.
CNS D-H7C D-B5, D-B6, D-B59W CLS HS HS Auto switch Auto switch 12 8.5 CLQ 24.5 16 MLGP A B A B 33 38.2 RLQ MLU Proper Auto Switch Mounting Position Auto Switch Mounting Height ML1C Auto switch model D-C7/C80 D-H7 D-H7W D-H7NF D-H7BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-C7/C80 D-C73C D-C80C D-B5/B64 DD-B5/B64 D-B59W D-G5NTL D-H7C D-C73C D-C80C D-G5NTL D-B59W -X Bore size (mm) A B A B A B A B
Signal contents 1-2 Unused 3 Terminal A of resistance temperature detector 4 Terminal B of resistance temperature detector 5 Terminal B of resistance temperature detector 1 2. Communication connector D-sub 9 pin (socket) Holding screw: M2.6 E 6 Contact a for output cutoff alarm (open when alarm occurs) 7 Common for output cutoff alarm 9 15 10 11 12 13 14 Pin no.
Dimensions inch (mm) AK3542 & 4542 M5 x 0.8 Actuation port 1.57 (40) 2.24 (57) 2 x Compression 2 x R, NPT male 2 x Rc, NPT female 0.44 (11.2) B B A A A Connections: N, BRN Connections: 4T, 6T Connections: 4, 6, BR 4 6 4 6 4 6 Ports A B Connections inch (mm) inch (mm) 4T 2.56 (65.0) 1.12 sq. (28.4) 1/4 inch compression 4BR 1.70 (43.2) Rc 1/4 4BRN 2.32 (58.9) 1.12 sq. (28.4) R 1/4 4 1.70
setting status signal B EnabledOpen A Output the input signal as it is SW1 Pass through signal of the contact input signal 1 B Reverse output of the input signal A Output the input signal as it is SW2 Pass through signal of the contact input signal 2 B Reverse output of the input signal A Selected alarm occurrence : Close A.SEL Selected alarm status signal B Selected alarm occurrence : Open
5-2.Dimensions C E C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
Comply with the requirements for FISCO field device Class I, Division 2, Groups A, B, C, and D; T4/ T5/T6 Ex ic IIC T4/T5/T6 Gc Class I, Zone 2 AEx ic IIC T4/T5/T6 Gc Ui 32 V, Ii 380 mA, Pi 5.32 W, Ci 5 nF, Li 10 H.
Adjustment bolt b CRA1 Adjustment bolt d CRQ2 q First adjust both rotation end positions. Apply pressure to ports A and C to adjust adjusting bolt b. Apply pressure to ports B and D to adjust adjusting bolt a. Lock the bolts with fixing nuts after adjustment. w Next, apply pressure to ports A to D to adjust the center position. Loosen the fixing nuts for adjusting bolts c and d.
Nil M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 TF G 1/8 G 1/8 G 1/8 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 b C H B d M10 x 1.0 M20 x 1.5 M26 x 1.5 M32 x 2.0 H 4 8 8 10 B 14 26 32 41 C 16.2 30 37 47.3 Part No.
The pressure difference generated at this time opens check valve and the residual pressure on the A port side is quickly exhausted from R port. 2 1(P) OFF 2(A) 1 3(R) 3 Soft Start-up Valve AV2000/3000/4000/5000 Construction B ON OFF B-B 1(P) 2(A) B 3(R) Parts list No. 1 2 3 Description Material Body Cap Cover ADC ADC ADC Replacement parts Description No. Part no.
M5 x 0.8 b Cv b Cv VV3Z1-01-1 VV4Z1-20-1 1/8 How to Order Manifold Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no.
U B A Approx. U A B D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U Approx. U Approx. U SMC SMC Approx. U A B B A Approx. U D-A73C D-A80C D-J79C B A A B Approx.
HS Auto switch Auto switch 12 8.5 24.5 16 A B A B 33 38.2 Auto switch mounting position Auto switch mounting height (mm) (mm) Auto switch model D-C7, C8 D-H7 D-H7W D-H7F D-H7BA D-H7 D-H7C D-H7W D-H7BA D-C7, C8 D-C73C D-C80C D-B5, B6 D-C73C D-C80C D-B5, B6 D-B59W D-G5NT D-H7C D-G5NT D-B59W D-H7F Bore size (mm) A A B A B A A HS HS HS B B B B A 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5)
Switch operating range Stroke (mm) 20 41 29 47 35 Type 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B MXP10 Auto switch MXP12 3 Screwdriver (Grip diameter 5 to 6mm) MXP16 2 Color indication solid state switch D-F9BW(V), D-F9NW(V), D-F9PW(V) mm Switch operating range Stroke (mm) 20 42 28 48 34 Type 25 47.5 33.5 30 56 46 10 32 18 15 37.5 23.5 A B A B A B MXP10 MXP12
U Values inside ( ) are for D-H7LF D-H7C B Approx.
Recommended Parameter Values [LEF] LEFS25 LEFS32 LEFS40 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
8370: JIS B 8361: JIS B 9960-1: (1 ) JIS B 8433-1993: 2) : : : 1. 2. 3. 1. 2. 3. 4