Note 2) Based on ISO8573-1:2010 Compressed air Part 1: Contaminants and purity classes. The compressed air quality class on the inlet side is [3:7:3]. -8- 4.

SPECIFICATIONS Model AL10-A AL20-A AL30-A AL40-A AL40-06-A AL50-A AL60-A Port size M5 1/81/4 1/43/8 1/43/81/2 3/4 3/41 1 Air Fluid 1.5 MPa Proof pressure 1.0 MPa Max. operating pressure Ambient and fluid temperature -5 60 (Should be no freezing) 1/430 3/840 1/250 15 Min. operating flow Note1) L/min(ANR) 50 1/430 3/840 4 190 220 Bowl capacity cm3 7 25 55 135 Class 1 turbine oil (ISO VG32)

8 1 8 ARM1000 57 1 8 1 8 IRV 1 4 1 8 ARM2000 136 1 8 1 8 VEX How to Order SRH ARM 1000 A1 5 01 G SRP Semi-standard Regulator for manifold Nil 1 0.7 MPa setting (Standard) 0.2 MPa setting SRF Number of stations Note 1) Pressure gauge for 1.0 MPa is used.

Model Option 10-/21-AW20(K)-B 10-/21-AW30(K)-B 10-/21-AW40(K)-B 10-/21-AW40(K)-06-B 10-/21-AW60(K)-B Bracket assembly Note 1) AW23P-270AS AR33P-270AS AR43P-270AS AW62P-270AS Note 2) Set nut AR23P-260S AR33P-260S AR43P-260S 10: G49-10-01, 21: G49-10-01-MS-X3 Standard Pressure gauge Note 4) Round type Note 3) 10: G49-4-01, 21: G49-4-01-MS-X3 0.02 to 0.2 MPa setting Note 1) Assembly of a bracket

Output mode Display resolution Hysteresis mode 1/10 of P_1(n_1), P_2(n_2) Window comparator mode 1/4 of P1HP1L(n1Hn1L), P2HP2L(n2Hn2L) Positive pressure, vacuum pressure: Rated maximum pressure 1/7 of the atmospheric pressure Compound pressure: Rated maximum pressure 1/4 of the atmospheric pressure Error output Positive pressure, vacuum pressure: Rated maximum pressure 1/7 of the atmospheric

Recommended Tightening Torque (Nm) Air Supply Connection thread 1/8 1/4 3/8 1/2 Caution 7 to 9 12 to 14 22 to 24 28 to 30 Torque 1. Use clean air. If chemicals, organic solvents, synthetic oil or corrosive gases are included in the compressed air, parts could be damaged or they can cause a malfunction. 2.

Note 4) Based on ISO8573-1:2010 Compressed air Part1: Contaminants and purity classes. The compressed air quality class on the inlet side is [ 2 : 7 : 3 ]. -8- 4. How to Order AMD D 30 03 B (1) Symbol Details Body size 20 30 40 Nil Rc Thread type N NPT F G 01 1/8 02 1/4 Port size 03 3/8 04 1/2 Nil Without mounting option a Mounting B With bracket Nil Without auto drain Options C N.C.

Note 4) Based on ISO8573-1:2010 Compressed air Part1: Contaminants and purity classes. The compressed air quality class on the inlet side is [ 4 : 7 : 4 ]. -8- 4. How to Order AM D 30 03 B (1) Symbol Details Body size 20 30 40 Nil Rc Thread type N NPT F G 01 1/8 02 1/4 Port size 03 3/8 04 1/2 Nil Without mounting option a Mounting B With bracket Nil Without auto drain Options C N.C.

AF-OMX0053-B PRODUCT NAME Mist Separator MODEL / Series / Product Number AFM20-(F,N)01(F,N)02(B,C)(-2,6,C,J,L,R,Z)-D AFM30-(F,N)02(F,N)03(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)02(F,N)04(B,C,D)(-2,6,8,J,L,R,W,Z)-D AFM40-(F,N)06(B,C,D)(-2,6,8,J,R,W,Z)-D Contents Page 1. Safety Instructions 2-7 2. Application 8 3. Standard Specifications 8 4. How to Order 9 5.

Consequently, (7) the exhaust valve of (1) the pilot valve moves to the right, the output pressure of OUT1 increases and (15) the diaphragm moves downwards.

M3 x 0.5 x 32 VP300-2-1P (Rc 1/8) VP300-2-2P (Rc 1/4) VP500-2-1P (Rc 1/4) VP500-2-2P (Rc 3/8) VP700-2-1P (Rc 3/8) VP700-2-2P (Rc 1/2) VPA344 VP300-17-1 VP300-24-4 M4 x 0.7 x 41 VPA544 VP500-17-1 Series Thread type VP500-24-3 M5 x 0.8 x 50 3 5 7 P F N T VPA344 VPA544 VPA744 Rc G NPT NPTF VPA744 VP700-17-1 VP700-24-1 Caution Port size Tightening Torque for Mounting Screw VPA344 1/8 1/4 VPA544

Note 4) Based on ISO8573-1:2010 Compressed air Part1: Contaminants and purity classes. The compressed air quality class on the inlet side is [6:8:4]. -8- 4. How to Order AFF D 30 03 B (1) Symbol Details Body size 20 30 40 Nil Rc Thread type N NPT F G 01 1/8 02 1/4 Port size 03 3/8 04 1/2 Nil Without mounting option a Mounting B With bracket Nil Without auto drain Options C N.C.

(mm) D Model B d H C SNJ-015A Y M10 x 1 3 14 16.2 E SN-015A M14 x 1 5 19 21.9 SNJ-010A M8 x 1 3 12 13.9 C A B Ball joint type: 40, 50 D E Y C A B (mm) D E Y ZP10F Model B A C 1.5 6.5 10 12 ZP13F 13 15 3 8.2 2 7 ZP16F 16 18 ZP20F 20 22 8.5 ZP25F 3 25 28 4 10.2 ZP32F 9 32 35 ZP40F 5 13 40 43 10 28 ZP50F 6 14 50 53 8 13-11-101 6 Vacuum Pad: Ball Joint Type Vertical Vacuum Entry Without Buffer

Window comparator mode (same as for positive pressure use) since the hysteresis will be 3 digits, separate P1 from P2 (in case of 2-output type, same as for P3 and P4) by 7 digits or more. : 1 digit is the minimum pressure display unit. -15No.PS-OMO0002-A 1-output type with the failure predictive function 1. Set value input mode Press the "SET" button to display "P1-50" 1.

L L L L L L L L L L L L: Low fixed (0) Input status area Input status area specifications Item Status State 0 Normal SOLV State of power supply for solenoid valve 1 Abnormal (19 V or less) Output area mapping For EX260-SEN1/-SEN2 Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 For EX260-SEN3/-SEN4

L L L L: Low fixed (0) Input status area Input status area specifications Item Status State 0 Normal SOLV State of power supply for solenoid valve 1 Abnormal (19 V or less) Output area mapping For EX260-SPL1 Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 For EX260-SPL3 Output data Offset MSB LSB

0 0 L L L L SOLV L L L L L L L L L L L L: Low fixed (0) Input status area Input status area specifications Item Status State 0 Normal SOLV State of power supply for solenoid valve 1 Abnormal (19 V or less) Output area mapping Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 -45No.EX-OMX1001 Dimensions

When screwing the piping or fitting into the valve, tighten it as follows. 1) When using SMC's fitting, follow the procedures below to tighten it. Connection thread: M5 First, tighten by hand, then use a wrench appropriate for the hexagon flats of the body to tighten an additional 1/6 to 1/4 turn.

Stations N R S 01 1 station Note 5) Note 6) The maximum number of stations differs depending on the electrical entry.

1 !2 !3 !4 !5 !6 !7 !8 !9 @0 @1 @2 Material Aluminum alloy Aluminum alloy Aluminum alloy Carbon steel Note Clear hard anodized Clear hard anodized Chromated No.