A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., Operation Manual, REGULATOR, ELECTRO-PNEUMATIC, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, .77161 lb, ModelITV101 ITV103 ITV105 ITV201 ITV203 ITV205 ITV203------------
A dedicated exhaust port (M5) is installed to remove air from the nozzle. The IT series comes with monitor signal output and shock/ vibration resistance., REGULATOR, ELECTRO-PNEU, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, 1.40139 lb
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover), Calibration Certification: K (w/Certificate
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective Cover), Calibration Certification: K (w/Certificate
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: A (NPN Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: E (PNP Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: D (Panel Mount Adapter+Front Protective Cover)
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: B (PNP Open Collector 2 Outputs), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover]
Pressure Range: 0.0 to -101.0kPa, Piping Specifications: M5R (M5 Female Thread/Rear Piping Port), Output Specifications: C (NPN Open Collector 1 Output+Analog Voltage), Unit Specifications: P (Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: D (Panel Mount Adapter+Front Protective