Series VXA31/32 Dimensions P port Bracket Pilot port J (Spanner flat) Port size P Port size Rc With bracket K 6 7.5 Symbol Model A B C D E F G H J L 29 32 M 14.5 17 1 8 1 4 VXA31 VXA32 19 25 20 20 18 21 20 20 22.5 27.5 42.5 47.5 71 80 81 90 21 27 , , 1 4 3 8 17-3-104 The VX series will be revised shortly.
As a general rule, use 80 to 100 mesh. The supply water includes materials that create a hard sediment or sludge such as calcium and magnesium. Sediment and sludge can cause the valve to not operate properly. Therefore, install a water softening device, which removes these materials, and a filter (strainer) directly in front of the valve.
As a general rule, use 80 to 100 mesh. The supply water includes materials that create a hard sediment or sludge such as calcium and magnesium. Sediment and sludge can cause the valve to not operate properly. Therefore, install a water softening device, which removes these materials, and a filter (strainer) directly in front of the valve.
Select the cylinder bore size so that the load is less than 80% of the holding force. If the piston rod slips because the lock's holding force has been exceeded, the brake shoe could be damaged, resulting in a reduced holding force or shortened life. 1.
Addl weight per each 2" of stroke NCA For all mountings style 0.38 0.48 0.51 0.97 1.06 DCylinder Bore and Force: Push Stroke -X Force (lbs); Push stroke Bore size (in) Piston area (in) Operating medium pressure (PSI) 2050 60 80 100 200 250 Data 1.5 1.767 88 106 141 177 353 442 2 3.142 157 188 251 314 628 785 2.5 4.909 245 295 393 491 982 1227 To calculate pull forces not shown in the table
Therefore, to use the cylinder near the upper limit of the constant holding force, be aware of the following: Select the cylinder bore size so that the load is less than 80% of the holding force. If slipping occurs when the load is over holding force, the brake shoe will be damaged, and it is possible the holding force will become smaller or the cylinder life shortened.
80 8 10 10 14 +0.058 0 +0.070 0 9-13-13 13 Series MLU Accessory Bracket Dimensions Double knuckle joint Single knuckle joint LC LC LX LX LA LA LB LB LDH10 LDH10 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com LU LU L L Z + Stroke Z + Stroke RR RR ZZ + Stroke ZZ +
Air Cylinder/Low Friction Type Series MBQ Replacement Procedure is 32, 40, 50 63, 80, 100 P.284 Construction !4 !5 !3 !7 !6 The numbers are the same as the "Construction" of the Best Pneumatics No.2 Series MBQ. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No. Replacement Parts: Seal Kit Kit no.
JIS Standard Hydraulic Cylinder/Double Acting, Double Rod Series CH2EW/CH2FW 32, 40 50, 63 80, 100 Replacement Procedure is P.396 Construction Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.
JIS Standard Hydraulic Cylinder/Double Acting, Single Rod Series CH2E/CH2F/CH2G/CH2H 32, 40 50, 63 80, 100 Replacement Procedure is P.396 Construction @9 @2 @4 @7 @8 @6 @1 #0 @3 @5 The numbers are the same as the "Construction" of the Best Pneumatics No.8 Series CH2E/CH2F/CH2G/CH2H. *BLUE links will lead to purchase pages. Seal Kit List Description Material Note No.
Contents Bore size (mm) CHSD40-PS 40 50 63 80 100 CHSD40-PS CHSD50-PS CHSD63-PS CHSD80-PS CHSD100-PS @1 @2 @3 @4 @5 26 Scraper NBR CHSD50-PS Rod seal NBR Set of left nos. @1, @2, @3, @4, @5, @9 CHSD63-PS Back-up ring Resin CHSD80-PS 26, 27 and 28 are non-replaceable parts, so they are not included in the seal kit.
ISO Standard Hydraulic Cylinder Series CHSG Replacement Procedure is 32, 40, 50 63, 80, 100 P.395 Construction CHSGB Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 80, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: Without auto switch (built-in magnet), Lead Wire Length(m): N/A, The number
(Drilling center) Horizontal machining center 1063 A LMU100/200 Series Oil Discharge Rate (Representative Value) Construction/Working Principle Conditions Oil: Turbine oil class 1 ISO VG32 Oil temperature: 26C LMU100ON/OFF valve for air blow 2 120 ON/OFF valve for oil mist 4 0.2 MPa Oil tank pressure Oil discharge rate cm3/min 100 Air adjusting needle for mist 10 Oil adjusting needle 11 80
Please contact SMC when disassemble is required.) 132 Guide Cylinder Series MGG 63, 80, 100 Construction 63 to 100/MGGB Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L.