Output specifications 25 (L) 26 (L) 67 (L) 26 (L) 27 (L) 67 (L) 1 output NPN open collector 30V, 80mA or less ZSE4 ZSE4B Analog output (1 to 5V) 1 output PNP open collector 80mA or less Analog output (1 to 5V) ZSE4E 2 outputs NPN open collector 30V, 80mA or less 2 outputs PNP open collector 80mA or less Refer to CAT.E824-A "Pressure Switch" for details on switches. 3 Series ZL Construction
CB CD CE CH CW F L A KK ER NY-150 NY-325 0.765 1.265 0.5 0.75 1 1/2 2 3/8 1 1 3/8 1/2 5/8 1 1 1/4 3/4 1 1/4 3/4 1 1/8 7/16-20 3/4-16 1/2 3/4 CD dia. KK Tap through Order to Match Rod Thread Rod Eye Pivot Pin Pivot Pin Part no. CD 1 CD 2 CL CP Part no. A CA CB CD ER KK Part no.
min Discharge rate l/min Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
As the flow rate when Kv = 1 is calculated as the formula: Q0 = 15 x 1/1.5 = 10 [L/min], read off P when Q0 is 10 [L/min] in Graph (2). The reading is 0.036 [MPa]. Example 2) Obtain the saturated steam flow rate when P1 = 0.8 [MPa] and P = 0.008 [MPa] with a solenoid valve with a Kv = 0.05 [m3/h]. Read off Q0 when P1 is 0.8 and P is 0.008 in Graph (2), the reading is 20 kg/h.
Controller side PLC side For 4 Axes JXC73/83 L JXC C2 (Terminal no.) (R1.25-4) 40 20 39 (7.5) 40 20 Cable length (L) [m] 50.8 1 1.5 3 3 5 5 2 21 1 21 1 Pin no. Wire color Pin no. Wire color Pin no. Wire color Pin no.
AS2002F-04 When connecting 4 pcs. and mounting L-brackets on both sides Speed controller AS2002F-04 4 pcs. L-bracket AS-20L 2 pcs.
LED EX245-LA1/LB1 LED LED . 9-15 4 (C/Q) LED No.0,2,4,6 LED Port deactivated (L+) (ON/OFF1Hz) IO-Link IO-Link (ON/OFF2Hz) IO-Link Device IO-Link (L+C/Q) OFF Digital input ON (L+) OFF Digital output ON (L+C/Q) . 9-16 2 (I/Q) LED No.1,3,5,7 (EX245-LA1A) LED status Description I/Q OFF Digital input (I/Q) I/Q ON . 9-17 2 (P24) LED No.1,3,5,7 (EX245-LB1B) LED status Description
Only air, N2, are applicable. [ 25] 25 L/min (PFMC7501) End stop position Set value [P_1] [ H_1] Hysteresis of OUT1 [ 50] 50 L/min (PFMC7102) Hysteresis [H_1] 225o [ 100] 100 L/min (PFMC7202) Flow [L/min] Do not use the product in a place where static electricity is a problem.
IDX-OM-W094 / Series IDFA60-23-A,C,L,R,T,V IDFA70-23-A,C,L,R,T,V IDFA80-23-A,C,L,R,T,V IDFA90-23-A,C,L,R,T,V URLhttp://www.smcworld.com/ English instruction manual can be downloaded from our URLhttp://www.smcworld.com/ SMC ISO4414 *1) JIS B8370 *2) *1) ISO4414Pneumatic fluid power Recommendations for the application of equipment to transmission and control systems. *2) JIS B8370 URLhttp:
With one-touch fitting For low speed control AS Needle Valve/Flow Characteristics ASP AS1001FM AS2001FM AS2051FM ASN 0.8 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 10 20 50 0.15 0.3 AQ Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Effective area (mm2) Effective area (mm2) Effective area (mm2) 40 0.6 ASV 0.1 0.2 30 AK 5 10 0.4 20 0.05
Air Cylinder/End Lock Series MBB 32, 40, 50, 63, 80, 100 How to Order MBB L 32 50 H N Standard H N L 32 50 A53 MDBB With auto switch Number of auto switches Built-in magnet S 3 n 2 1 3 n Mounting Manual release Basic/Without bracket Axial foot Front flange Rear flange Single clevis Double clevis Center trunnion B L F G C D T Bore size N L Non-locking Locking 32 40 50 63 80 100 Without auto
at a flow volume of 1000 l/min (ANR), the inlet pressure will be 0.05 MPa.
G Rear flange F Front flange L Foot C Male rear clevis D Female rear clevis 1.8-29
L (Ex.) A53L 5m . Z (Ex.)
B + Stroke A + Stroke 93.5 75.5 83.5 65.5 6.6 9 67 76 89 50 95 77 89 71 9 9 80 92 108 63 Rod end male threads Bore size (mm) L L1 M 32 17 38.5 34 40 17 38.5 40 50 18 43.5 50 63 Rod end nut L1 18 43.5 60 Rear flange type/CBQ2G, CDBQ2G (mm) Rear flange type With rear lock With front lock Bore size (mm) L L1 A A FV M 80.5 73 7 28.5 32 90 79.5 7 28.5 40 4-FD FT L 92.5 82.5 8 33.5 50 B + Stroke
A K = 1 L A L A End plate mounting Mp Mr W My W W W L A W L A L A K = 0.6 W Mey Mep L A A L Note 1) Static moment: Moment generated by gravity Dynamic moment: Moment generated by impact when colliding with stopper Max. allowable load weight: Wmax(kg) Allowable kinetic energy: Emax (J) Table 1 Table 2 Allowable load weight coefficient: Graph 1 Model Allowable kinetic energy Adjuster option
(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without an unit switching function.)
How to order L E C C G 2 L Cable length(L) K 0.3m L 0.5m 1 1m ii. Dimensions (4) Branch connector i. How to order L E C C G D Branch connector ii. Dimensions (5) Terminating resistor i. How to order L E C C G R ii. Dimensions 71 - 8.