SMC Corporation of America
Elite Part Number Search
Search Results "VXA2240-02F-1-B"

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VX3 BODY PT 1/4, VALVE, VX3 3-WAY MEDIA VALVE, FC, VX3 BODY PT 1/4, 0.94483 lb, Port sizeOrifice diameter (mm?)

Please contact us for the latest version.sales@ocaire.com, VX3 BODY PT 1/4, VALVE, VX3 3-WAY MEDIA VALVE, FA, VX3 BODY PT 1/4, 1.76369 lb

Please contact us for the latest version.sales@ocaire.com, SY5000 BASE MT 1/4, VALVE, SY5000 SOL/VALVE, RUBBER SEAL, PG, SY5000 BASE MT 1/4, 0.44092 lb

Please contact us for the latest version.sales@ocaire.com, SY5000 BASE MT 1/4, VALVE, SY5000 SOL/VALVE, RUBBER SEAL, PF, SY5000 BASE MT 1/4, 0.23486 lb

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VX3 BODY PT 1/4, VALVE, VX3 3-WAY MEDIA VALVE, FA, VX3 BODY PT 1/4, 1.54125 lb

Please contact us for the latest version.sales@ocaire.com, VX3 BODY PT 1/4, VALVE, VX3 3-WAY MEDIA VALVE, FA, VX3 BODY PT 1/4, 1.24675 lb

Valves are easily replaced without changing existing piping.Direct operated, 3 port solenoid valve for manifold - New VX Series, Max. system pressure (MPa): 2.0, Flow characteristics: 0.08 ~ 0.5 Cv, Voltage: 48, 100, 200, 110, 220, 230, 240VAC; 12, 24VDC, VX3 BODY PT 1/4, VALVE, VX3 3-WAY MEDIA VALVE, FC, VX3 BODY PT 1/4, 1.51874 lb

Please contact us for the latest version.sales@ocaire.com, VX3 BODY PT 1/4, VALVE, VX3 3-WAY MEDIA VALVE, FC, VX3 BODY PT 1/4, 1.26765 lb

They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1) , and other safety regulations. *1) ISO 4414: Pneumatic fluid power -General rules relating to systems. ISO 4413: Hydraulic fluid power -General rules relating to systems. IEC 60204-1: Safety of machinery -Electrical equipment of machines .

XDD file Model number XDD file 1 EX260-SPL1 F0007_EX260-SPL1.xdd 2 EX260-SPL3 F0007_EX260-SPL3.xdd The network configuration procedure using the B&Rs Automation Studio is described below. 1) Select "Import Fieldbus Device" from "Tools" in the Main menu, and install XDD file.

/4 115/1/60 1 NPT 232 R134a 17.7 21.3 19.9 3.3 8.3 82 PDE30-S 137 4.4 5.7 1 230/1/60 1 NPT 174 R134a 21.3 26.4 25 3.1 10.2 126 PDE40-S 137 5.1 6.5 1 1/4 230/1/60 1 1/4 NPT 174 R134a 23.2 32.3 31.7 3.5 11.4 168 PDE50-S 168 6.3 8.2 1 1/2 230/1/60 1 1/2 NPT 174 R134a 23.2 32.3 31.7 3.5 11.4 207 PDE60-S 200 7.2 10.4 1 3/4 230/1/60 2 NPT 174 R134a 23.2 32.3 31.7 3.5 11.4 227 PDE75-S 235 7.5 10.7

Introduction. 1-1 1.1 Outline .1-1 1.1.1 List of Models Compatible with the SMC VLS software . 1-1 1.1.2 Product Configuration. 1-1 1.1.3 Major Features of the ECC-PNAL-PCS/WIN-E Software. 1-1 1.2 Definitions.1-2 1.3 Abbreviations.1-2 2. Installation . 2-1 2.1 Operating System Requirements.2-1 2.2 Installation.2-1 2.3 Uninstallation .2-1 2.4 System Configuration .2-2 3.

Minimum Stroke for Auto Switch Mounting [mm] Auto switch model Number of auto switches Bore size 12 (10 x 2) 16 (12 x 2) 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) D-M9V 1 5 2 5 D-M9 1 5 Note 1) 5 2 10 Note 1) 10 D-M9W 1 5 Note 2) 2 10 Note 2) 10 D-M9WV D-M9AV 1 5 Note 2) 2 10 D-M9A 1 5 Note 2) 2 10 Note 2) Note 1) Confirm that it is possible

JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4. 2 VT315**-OMH0005-A / / / / 1 1 1 1 1.5 1.5 1.5 1.5 *3) *3) *3) *3) * * * *3) 3) 3) 3) 1 1 1 1 1 1 1 1 () 3 VT315**-OMH0005-A VT315 Series VT315 Series VT315 Series VT315 Series 3 3 3 3 / / / / / / / / 3 () C-R ( )C-R DC 5% () () () ( ( ( ( ) ) ) ) () AC 15% (SSR (SSR (SSR (SSR ) ) ) ) AC AC AC

) B C Panel type One-touch fitting feature introduced to series mm Weight Model A (Width) C (Depth) B (Height) Approx. 70g (Body: 65g) 4, 6 (metric size) 5/32", 1/4" (inch size) ARJ310-01G 18.3 Approx. 41 82.5 Approx. 75g (Body: 60g) ARJ210-M5G 18.3 80 Approx. 46 Miniature Regulator Series ARJ310 How to Order Port size (IN, OUT) 1/8 (male thread), M5 x 0.8 (female thread) 1/8 (female thread

JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety, etc. *2) Labor Safety and Sanitation Law, etc.

JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment for machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. *2) Labor Safety and Sanitation Law, etc. Caution Operator error could result in injury or equipment damage.

) Exhaust (OUTEXH) Model IN, OUT EXH C(dm3/s-bar) b Cv C(dm3/s-bar) b Cv VHS20 1/8 1/8 4.0 0.41 1.1 3.7 0.42 1.1 1/4 5.8 0.31 1.4 3.8 0.42 1.1 6 VHS30 1/4 1/4 8.8 0.44 2.4 8.0 0.46 2.3 3/8 14.1 0.28 3.5 7.8 0.46 2.2 1/4 9.5 0.49 2.8 13.3 0.47 3.6 VHS40 3/8 17.2 0.47 4.8 13.6 0.47 3.7 3/8 1/2 26.7 0.29 6.3 13.4 0.43 3.7 -6- 4.

In order of (1) and (2) on drawing on the right Orientation mark (1) (2) 5-5 [Mount and tighten V-band] Collar of cover Cover V-band Case O-ring Collar of case Fig. (a) Correct mounting of V-band Fig. (b) Incorrect mounting of V-band (Not correctly fit with collar of cover (1) Mount V band to the collar of the cover and the case correctly. [Refer Fig.