Version: 2, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-standard Indicator: Non-standard Indicatior, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: N1

Version: 2, Auto Switch: w/o Auto Switch and w/o Built-in Magnet, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: None, Voltage: 24 VDC, Electrical Entry: L Type Plug Connector, Surge Suppressor: w/Light & Surge Voltage Suppressor, Non-standard Indicator: Non-standard Indicatior, Body Surface Treatment: External - Hard Anodized; Internal - Oxalic Acid Anodized, Seal Material: N1

Flange Size: 25mm, Heater: None, Non-standard Indicator: Non-standard Indicator, Body Surface Treatment: External: Hard Anodized; Internal: Raw Material, Seal Material: N1 [EPDM (2101-80)], Seal Replacement: Valve Seal, Exterior Seal

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side)

Model: 10M (Side-Ported), Valve Stations: 4 Stations, P, E Port Location: U Side, SUP/EXH Block: Internal Pilot, A,B Port Size: N1 (ø1/8" One-touch Fitting), Mounting: D (DIN Rail Mounting w/o Name Plate), DIN Rail Option: 6 (Longer than Standard DIN Rail)

Rated Flow Range: 02 (0.02 to 2 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)

Enclosure: W (IP67), SI Unit: EA (EtherNet/IPâ„¢ - 32 Outputs - Connector M12), SI Unit Output Polarity: N (-COM), Stations: 16 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N1 (1/8" One-touch Fitting), Mounting: D0 (DIN Rail Mount w/o DIN Rail)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: W (With Flow Adjustment Valve, Rear Ported), Port Size: N1 (NPT1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve), Calibration Certificate: A

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate), Made to Order: X731 (Compatible with Argon

Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: A (Out 1: NPN; Out 2: NPN)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: N1 (1/8 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: With lead wire with connector (3 m/5 core), Unit Specification: Unit Specification, Bracket: None, Operation Manual/Calibration Certificate: Y (None)

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only)

Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N1 (NPT1/8), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)

Enclosure: W (IP67), SI Unit: DA (EtherCAT - 32 Outputs - Connector M12), SI Unit Output Polarity: +COM, Stations: 5 Stations, P, E Port Entry: B (Both Sides 2~16 Stations), SUP/EXH Block Assembly: Internal Pilot, A, B Port: N1 (1/8" One-touch Fitting), Mounting: D (DIN Rail Mounting), DIN Rail Option: 9 (for 9 Stations; Longer Rail than Total Length of Specified Valve Stations)

Stations: 7 Stations, Port Size: N1 (1/8" One-touch Fitting), Cable Length: 0 (0.6m Cable), Option 1: None, Option 2: D (DIN Rail Mounting)

Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)

Bore Size: 16mm, Action: D (Double Acting), Finger Position: N1 (Narrow Style Side Tapped), Body Option: Basic, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: X79 (Grease for Food)

Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: L (Out 1: IO-Link or NPN/PNP), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)