SMC Corporation of America
Elite Part Number Search
Search Results "VXA2240-02F-1-B"

This will cause a malfunction. 8 1 R , 4 1 R G 1 4 The dimensions in ( ): Connecting thread R X2: Stud parts nickle plated 8 1 R PPA 8 1 R , 4 1 R AL 8 1 R , 4 1 R X3: Wetted parts stainless steel MPa 8 1 R 8 1 R , 4 1 R 8 1 R , 4 1 R X4: Oil-free (Wetted parts degreasing) 8 1 R 8 1 R , 4 1 R How to Order G 43 01 Option Connection thread size Symbol Specifications Nil X2 X3 Stud parts nickel

EX245-DY1 . 70 3 No.EX-OMU0020CN 1) (ISO/IEC)(JIS) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: (1 : ) JIS

00 0 0 0 0 0 0 0 0 FF 1 1 1 1 1 1 1 1 Output Output 24-27: No. 31 30 29 28 27 26 25 24 31 30 29 28 27 26 25 24 Force output 4 24-31 Output 28-31: Setting value F0 1 1 1 1 0 0 0 0 0F 0 0 0 0 1 1 1 1 Hold last state Structure of Output Switching Counts (index68) The output switching count parameter consists of thirty-two sub-indices that represent bit fields with a size of 32 bits each.

ON H OFF Blue 50msec PFA7H-(-M) 28 29 B C D E F G H I J A Model Brown PFA703H PFA706H PFA712H 55 160 40 92 67 55 Rc 1, NPT 1, G 1 36 M5 x 0.8 8 OUT1 80mA Load Black 65 180 45 104 79 65 Rc 1 1/2, NPT 1 1/2, G 1 1/2 46 M6 x 1 9 ON OFF 75 220 55 114 89 75 Rc 2, NPT 2, G 2 56 M6 x 1 9 50msec PFA7H-(-M) 68 69 Analog output 1 to 5VDC 4 to 20mADC 5 20 Analog output [mA] Analog output [V] 1 4 Min

(mm) 2(A) Port size R(PT) 2(A) Port size R(PT) 1(P) 1(P) 1(P) 4 6 8 10 12 M5 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) M5 M5 4 M5 4 Tube O.D. (mm) Tube O.D.

(mm) Port size R 1 8 1 4 3 8 1 2 1 8 1 4 3 8 1 2 4 6 8 10 12 1(P) 1(P) M5 4 6 8 10 12 1(P) 1(P) M5 Applicable tubing O.D. (mm) Applicable tube O.D. (mm) Applicable tubing O.D.

Note 1) 1 1/4B 90 1 1/2B 120 Note 2) 2B 200 2 1/2B 315 3B 450 Description Part no.

Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS131FG-M5 AS121FG-M5 M5 x 0.8 AS231FG-01 AS221FG-01 R 1/8 AS231FG-02 AS221FG-02 R 1/4 AS331FG-02 AS321FG-02 R 1/4 AS331FG-03 AS321FG-03 R 3/8 AS431FG-04 AS421FG-04 R 1/2 AS131FG-U10/32 AS121FG-U10/32 10-32 UNF AS231FG-N01 AS221FG-N01 NPT 1/8 AS231FG-N02 AS221FG-N02 NPT 1/4 AS331FG-N02

1 Specifications 6 1 IDX-OM-X004 Heatless Air Dryer 6 References 6-2 Externals dimensional drawing Tube Size related to installation Bracket connection Model A B C D E Part No.

High Suction Vacuum Work 1 Work 2 Work n Max.A ON point OFF point Min.B Not adsorption Work 1 Work 2 Work n Atmosphere A B 4 A B 4 = A ON point Max.A: Maximum pressure value when workpiece is vacuumed. Min.B: Maximum pressure value when workpiece is not vacuumed.

Green Gray Tan Symbol B R G BU W Y YR N S PU BR GD GR T S S S S S S S S S S = Standard, all other length color combinations are available by special order Tube Sizes 1/8 5/32 3/16 1/4 5/16 3/8 1/2 5/8 3/4 21

69 M4 x 0.7 6 4.5 67 M5 x 0.8 25 60 105 48 45 23 13 18 69 32 17 2.5 118 CYP32 8.6 115 M6 x 1 8 7.5 90 Rc 1/8 50 100 138 87 79.5 29 17 22 115 46 27 3.5 155 Note 1) These dimension drawings indicate the case of piping port position "Nil".

Return 0.5 0.4 0.2 0 0 Out -0.2 -0.4 -0.5 -0.6 -0.8 0 25 50 75 -1 1 2 3 4 -1 100 5 Input signal % F.S.

) With unit conversion function 1 PNP open collector 1 output 65 PNP open collector 1 output 1: The new Measurement Law prohibits the unit conversion function in Japan.

to 186 1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x

5 20 40 5 20 40 2 1 1 0 0 0 20 40 60 80 100 0 20 40 60 80 100 Duty [%] Duty [%] Fig. 4-3 Allowable thrust force setting values.

4/5Port Air Operated Valve Series VFA3000 Model Configuration Port size Rc(PT) Effective area (mm2)(Cv) Rc(PT) Pilot port size Rc(PT) Weight (kg) Valve model 1 8 Rc(PT) 1 4 Rc(PT) 15.3 (0.85) 18 (1) 3 8 1 8 1 4 1 8 VFA3122-F 2 position single ,EXH: 01 02 0.18 1 8 1 8 1 4 14.4 (0.8) 18 (1) 01 02 VFA31302 position single (EXH: ) 0.15 1 8 1 8 Body ported Base mounted (With sub-plate) 1 8 1 4

P_1 = A-(A-B)/4 A = Maximum pressure value H_1 = | (A-B)/2| B = Minimum pressure value To clear the stored auto-preset settings, press the and buttons simultaneously for 1 second or longer. -31NO.TQ1050188-OM002 [F 6] Fine adjustment of display value This function is used to manually perform fine adjustment of the displayed pressure. It is adjustable within the range 5% R.D.

P_1 = A-(A-B)/4 A = Maximum pressure value H_1 = | (A-B)/2| B = Minimum pressure value To clear the stored auto-preset settings, press the and buttons simultaneously for 1 second or longer. -29No.TQ0010298-OM003-A [F 6] Fine adjustment of display value This function is used to manually perform fine adjustment of the displayed pressure. It is adjustable within the range 5% R.D.