SMC Corporation of America
Elite Part Number Search
Search Results "13-MXS12-20-A93V"

) 25 1.5 40 13 10 (13) 1/8 17 15 (17) 20 1.5 50 14 12 (14) 1/4 18 16 (18) 20 3 63 14 12 (14) 1/4 18 17 (18) 20 3 80 20 16 (20) 3/8 24 20 (24) 20 4 100 20 16 (20) 1/2 24 20 (24) 20 4 Bore size NA S TA TB ZZ Bore size TC TD TE TF TG 20 24 69 (77) 11 11 106 (114) 25 29 69 (77) 11 11 111 (119) 32 35.5 71 (79) 11 10 (11) 113 (121) 40 44 78 (87) 12 10 (12) 130 (139) 50 55 90 (102) 13 12 (13) 150

58 70 88 104 14.6 7 20 24 29 35 14 14 13 17 17 39.5 45.5 53.5 67 83 106 129 30 32 38 50 57 3.6 3.6 3.5 4.5 4.5 5.8 5.8 6.5 8.5 10 14 14 40.8 40.8 46.7 67.3 67.3 5.4 (Max. 11) 5 (Max. 11) 5 (Max. 16.5) 8 (Max. 20) 9 (Max. 25) RB0806 RB0806 RB1007 RB1412 RB1412 6 6 7 12 12 10 12 14 17 MY1M25 MY1M32 MY1M40 66 80 91 6 6 6 54 67 78 13 16 17.5 MY1M50 MY1M63 6 6 40 52 20 26 66 77 26 31 5.5 5.5

32 32 25 25 0.1 0.1 20 20 15 15 10 10 0.01 0.01 0 0 20 40 100 60 80 20 40 100 60 80 Overhang L (mm) Overhang L (mm) CXSJM CXSJL Graph V = over 400 mm/s; up to 50 mm stroke 13 CXSJM CXSJL Graph V = up to 400 mm/s; up to 50 mm stroke 12 1 1 Weight m (kg) Weight m (kg) 32 32 0.1 0.1 25 25 20 20 15 15 10 10 0.01 0 20 40 100 60 80 0.01 0 20 40 100 60 80 Overhang L (mm) Overhang L (mm) 5 Compact

h E F EA h EB W F Stroke adjusting unit S (Shock absorber stroke) T MY1W16, 20 F MY1W50, 63 Shock absorber EC EY h 3.6 3.6 3.5 4.5 4.5 5.5 5.5 TT 5.4 (Max. 11) 5 (Max. 11) 5 (Max. 16.5) 8 (Max. 20) 9 (Max. 25) 13 (Max. 33) 13 (Max. 38) S 40.8 40.8 46.7 67.3 67.3 73.2 73.2 E 14.6 20 24 29 35 40 52 EY 39.5 45.5 53.5 67 83 106 129 EC 5.8 5.8 6.5 8.5 10 14 14 EB 30 32 38 50 57 66 77 Model MY1W16

) 32 32 25 25 0.1 0.1 20 20 15 15 10 10 0.01 0.01 0 0 20 40 100 60 80 20 40 100 60 80 Overhang L (mm) Overhang L (mm) CXSJM CXSJL Graph V = over 400 mm/s; up to 50 mm stroke 13 CXSJM CXSJL Graph V = up to 400 mm/s; up to 50 mm stroke 12 1 1 Weight m (kg) Weight m (kg) 32 32 0.1 0.1 25 25 20 20 15 15 10 10 0.01 0 20 40 100 60 80 0.01 0 20 40 100 60 80 Overhang L (mm) Overhang L (mm) 5 Compact

Note 3) Load current range and Maximum load current 5 to 40 mA 5 to 20 mA 20 mA Contact protection circuit None D-A93: 2.4 V or less (up to 20 mA)/3 V or less (up to 40 mA) D-A93V: 2.7 V or less Internal voltage drop 0.8 V or less Indicator light Red LED illuminates when turned ON.

Applicable load IC circuit, Relay, PLC Load voltage 24 V or less 48 V or less 100 V or less AC DC AC DC AC DC Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None 1 or less (including lead wire length of 118"(3m)) Internal resistance D-A93, D-A93V, D-A96, D-A96V (With indicator light) D-A93, D-A93V D-A96, D-A96V Auto switch part no.

2 pcs. 5 10 15 15 20 20 25 15 32, 40, 50 32, 40, 50 5 15 10 5 1 pc. 10 10 20 1 pc. 5 5 10 15 15 20 25 15 Besides the models listed in How to Order, the following auto switches are applicable.

Cylinder stroke (mm) Bore Size (mm) 100 75 50 25 12 0.41 0.37 0.33 0.29 20 0.80 0.74 0.68 0.62 Rod End Nut Dimensions Material: Steel 30 d D C H B (mm) Applicable bore size (mm) 12 20 d H B C D M5 x 0.8 3 8 9.2 7.8 M8 x 1.25 5 13 15.0 12.5 Electrical Wiring Output type The output signal of the high precision scale cylinder is A/B phase difference output (open collector output) as shown in

M2 M3 m1 m2 m3 16 25 40 16 25 40 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 100 120 100 38 35 35 MY2HT 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load. Refer to each graph regarding the maximum allowable moment and maximum allowable load for a particular piston speed.

30 80 50 5 192 40 100 60 5 232 45 Size D (g6) G H M N U UU L 30 8 6 13 10 8 53 63 7.8 50 15 11 27 20 15 89 109 14 63 17 13 29 22 17 105 127 16 80 20 15 38 25 20 130 155 19 100 25 19 44 30 25 156 186 24 Note) Dimension parts different from the standard conform to the general tolerance.

(mm) D-A90V D-A96V D-A93V 22 Bore size D-F9V D-F9WV D-F9 D-F9W D-A90 D-A96 D-A93 (mm) 32 20 Mounting patternq, w 32 35 Mounting patterne 20 12 Auto Switch Mounting As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries. Insert the auto switch into the switch groove.

M1 M2 M3 m1 m2 m3 16 25 40 16 25 40 16 25 40 5 4 3.5 18 16 14 MY2H 13 14 10 35 35 30 45 33 28 68 66 57 7 6 7 15 13 13 MY2H 28 26 26 32 30 30 60 50 60 62 62 62 46 55 46 20 18 18 MY2HT 100 120 100 38 35 35 200 220 200 80 80 80 The above values are the maximum allowable values for moment and load.

IC circuit, Relay, PLC Applicable load 24 V AC/DC or less Load voltage 48 V AC/DC or less 100 V AC/DC or less Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None 1 or less (including lead wire length of 3 m) Internal resistance D-A93/D-A93V/D-A96/D-A96V (with indicator light) D-A93/D-A93V D-A96/D-A96V Auto switch part no.

Description Qty. 4 Seal 1 4 Seal 1 4 Seal 1 12 Gasket 4 12 Gasket 4 12 Gasket 4 Parts included 13 O-ring 4 13 O-ring 4 13 O-ring 4 in seal kit 17 Wear ring 4 17 Wear ring 4 17 Wear ring 4 18 Piston seal 4 18 Piston seal 4 18 Piston seal 4 27 Seal washer 2 27 Seal washer 2 27 Seal washer 2 < External shock absorber type > Description Size 10 20 30 50 P523010-6 P523020-6 P523030-6 P523040-6

16 20 25 32 40 5.5 6 2.5 0.5 1 1.5 4.5 4 7.5 9.5 9 11.5 5.5 6 10 11 12 16 14.5 15 11.5 9.5 10 7.5 0 0 3.5 5.5 5 7.5 3.5 3 6.5 8.5 8 10.5 1.5 2 6 7 8 12 1.5(4) 4.5 5 9 10 11 15 2(4.5) Bore size (mm) 1.5(1) 3.5(1) 3(0.5) 5.5(3) Long stroke 12 16 20 25 32 40 1 0.5 6 8 10.5 16.5 11 10.5 16 18 20.5 26.5 9 9.5 13 14 12.5 16 5 5.5 9 10 8.5 12 7 6 11.5 13.5 16.5 22.5 5(2.5) 8 8.5 12 13 11.5 15 10

D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.

) TL JJ US TA TD G L UW TB TC M N b l 90 180 90 180 90 180 3 29 104 130 122 153 20 0 0.03 1 15 59 24.5 8 11 9.6 11.5 4 13.5 27 4 4 2.5 74 20 M5 x 0.8 depth 6 0 0.03 30 2 18 65 27 10 13 11.4 13.5 19 36 4 4 2.5 83 4 33 4 20 40 139 177 5 37 5 M6 x 1 depth 7 0 0.03 93 11 20 15 14 17 25 73 32.5 2 20 5 3.5 39.5 5 Dimension AU does not indicate the dimension when shipped because of the adjustment

Refer to pages 8-13-12 to 8-13-13 for detailed selection procedures. 8-13-6 7 Model Selection Series MY2 Moment/MY2C MY2C/M1 MY2C/M3 MY2C/M2 50 40 50 40 50 40 30 30 30 MX 20 20 20 MTS MY 10 10 10 MY2C40 CY Moment Nm Moment Nm Moment Nm MY2C40 MY2C40 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800

Solid state switch D-F8 CUJ (As compared with SMC Series CU cylinders without magnet) Dimensions (Without magnet) Series Variations Bore size (mm) A(a) B(b) C(c) Bore size (mm) Rod end configuration Stroke (mm) Clean series 4 6 8 10 15 20 b Action Series Auto switch B Double acting Male thread Without thread None 4 10() 15() 13() 4 Single acting, Spring return 6 13(13) 19(22) 13(33) Double