Made to Order Series Compatible with Secondary Batteries 1 For details about 25A-, refer to the WEB catalog Series Compatible with Secondary Batteries/Series 25A-. X536 X538 X555 How to Order 25AVP 4 5DZ1 Fill in according to How to Order above. Note) Electrical entry can be selected only for D type. Check valve type is available only when the thread type is Rc.
Description VNC1 -6A, 8A, 10A VNC2 -10A, 15A VNC3 -20A VNC4 -25A VNC5 -32A, 32F VNC6 -40A, 40F VNC7 -50A, 50F No.
2 (Same surface) 100 D-G39 D-K39 D-A3l n (Different surfaces) 35 + 30 (n 2) (n = 2, 3, 4) n (Same surface) 100 + 100 (n 2) (n = 2, 3, 4) 1 10 2 (Different surfaces) 35 2 (Same surface) 55 n (Different surfaces) 35 + 30 (n 2) (n = 2, 3, 4) D-A44 n (Same surface) 55 + 50 (n 2) (n = 2, 3, 4) 1 10 D-F5l D-J59 D-F5lW D-J59W D-F5BA D-F59F 2 (Different surfaces, same surface) 15 25 25 n (Same
INP 1 INP ON 0.50 2 INP ON a bINP ON < / [mm/sec] [mm/sec] 1 4 30% 1 4 40% 5 20 35% 5 20 60% LEY*16** 21 50 60% 85% LEY*16*A* 21 50 80% 95% 1 4 20% 1 4 40% 5 20 35% 5 20 60% LEY*25** 21 35 50% 65% LEY*25*A* 21 35 80% 95% 1 4 20% 5 20 35% LEY*32** 21 30 60% 85% -41- LEY*16** LEY*25** LEY*32** LEY*16*A* LEY*25*A* A B C A B C A B C A B C A B C [kg] 1 1.5
Even when the ambient temperature range is within the specifications, do not use in locations where there are rapid temperature changes. 35 Series VQC Specific Product Precautions 4 Be sure to read before handling. Refer to pages 29 through 32 for safety instructions and common precautions. Power Supply Safety Instructions Caution Cable Safety Instructions Caution 1.
5.5 8 50 77 91 Side support B MY-S25B M6 x 1 35 77 8 50 91 A set of side supports consists of a left support and a right support.
Solenoid Specifications Apparent power (VA) Inrush Holding Power consumption (W) (Holding) Temperature rise (C ) (Rated voltage) Frequency (Hz) 50 25 12 60 20 8 Model Power source 5 50 3.5 35 6 50 8 55 6.5 45 8 50 0.5 60 9.5 50 11.5 55 Note) They are values in an ambient temperature of 20C 5C and application of rated voltage.
2.3 25 34 56 TQ 80 90 50 60 35 44 17.5 22 85 101 93 109 5 6 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 61.5 74 637 A VND Series Port size: 32A, 40A, 50A H (Valve open) Indicator (Option) Pilot port 12(P1), 10(P2) Port size: refer to table below P1 P2 F G E A 32 B D J Main port 1(A) (Back side 2(B)) C A B Port size: refer to table below Main port 1(A), 2(B) Pilot port 12(P1), 10(P2
G (Valve open) Pilot port Indicator (Option) (Back side P2) Bracket (Option) Main port Main port Rc A B C D E F G M N P Q R S T U Model 3 8 1 2 3 4 1 VND20D-10A VND20D-15A VND30D-20A VND40D-25A 63 42 28 14 73.5 81.5 4 52 26 4.5 24.3 2.3 25 34 56 80 90 50 60 35 40 17.5 20 85 101 93 109 5 6 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 61.5 74 17-4-40 5 Series VND Steam Valve: 2 Port Valve
Operating temperature range 0 to 50C (with no freezing and condensation) Environmental resistance Operating humidity range Operating, Storage: 35 to 85% R.H.
M6 x P0.5 5.5 M5 x P0.5 4.5 9.5 8.5 71 (17.7) 124 92 Bleed 52.5 63 Exhaust 46 Bleed OUT(2) SUP(1) 43 G OUT 2 SUP(1) OUT(2) 30 50 50 2 x Rc 1/8 9.5 60 35 EXH Pressure gauge port 43 2 x Rc 1/8 Pressure gauge port 35 2 x Rc 1/8 Port size 2 x Rc 1/4 Port size IR300-0 82 60 Mounting hole 12.5 2.3 48 Bracket (Option) Panel mounting hole Max.4 Pressure gauge (Option) Panel When mounting on a panel
Please contact us for the latest version.sales@ocaire.com, HEAD COVER (CXSL32), ACTUATOR, CXS GUIDED CYLINDER, L1, 32MM CXS PART, .02332 lb, ModelPart numberNo. of bumpersCXS32CXS32-34A 287511
Result area (LER ) ) LEY16RA-100BMLLEY16RA-100 LERH30K-3LLERH30K-3 0 ) LEY16RA-75LEY16RALEY16RA-100 LEFSH LEFS ) LEFSH25RH-300LEFS25RH-300LEFS25RH-300 11-)(25A-) 11-25A-11-25A) 11-LEFSH16A-100BRLEFS16A-100LEFS16A-100 29 No.SFOD-OMT0011CN-A c) Execute Execute b) c) (Apply) d), d) download e) 30 No.SFOD-OMT0011CN-A (2) a View(V) 4.1 (1-1-2) View (V) b c) download e) 31 No.SFOD-OMT0011CN-A
SI : G : 1[L/min]=0.2642[gal/min] 1[gal/min]=3.785[L/min] 1=9/5+32 L/min 100L/min250L/min Rc N NPT F G IS0228 1 N M8(3m) 04 20 40 11 21 03 3/8 04 1/2 06 3/4 10 1/1 12 11/4 14 11/2 / OUT1 OUT2 1 1~5 V 2 4~20 mA 1T 1~5 V 1~5 V (PF3W3)1~5V (-1-1T) 4~20mA(47) -11No.PF-OMN0009CN-F PVC PF3W5 U 48 () 3 A : 11 21 10~100 L/min 30~250 L/min U PVC 2 11 21 R (PVC) 11 21 40 11 21 25 25A
Accessory Function plate for VO307 (D sealing, with thread): DXT152-14-5A 628 A VNH Series High Pressure Coolant Valve 3.5 MPa, 7.0 MPa Specifications 3 port valve 2 port valve A B Model A B VNH211 -15A A B VNH311 -20A A B VNH411 -25A A B VNH113 -10A A B VNH213 -15A A B VNH313 -20A A B VNH413 -25A A B VNH133 -10A A B VNH233 -15A A B VNH333 -20A A B VNH433 -25A VNH111 -10A Operating fluid
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Bore Size: 32mm, Thread: ø6-ø20 Bore: M Thread; ø25,ø32 Bore: Rc 1/8, Stroke: 35mm
Size (Nominal x Length) Quantity Metric size Inch size TMH-23J TMH-01J M3 x 15 TMH-04J TMH-03J TMH-06J TMH-07J M3 x 20 TMH-06 TMH-07 M4 x 25 TMH-08 TMH-09 TMH-10 M4 x 35 TMH-12 TMH-13 1 Series Select the applicable holder/TMH for each speed controller from the table below.
For clean type (11-) or secondary battery (25A-) type actuator Search without entering 11or 25A-, and select the actuator for which the part number after 11or 25Amatches. e.g.) For 11-LEFSH16A-100BR, enter "LEFS16A-100" and select LEFS16A-100.