SMC Corporation of America
Elite Part Number Search
Search Results "53-SY5120-TT6-01N-F2"

15V2F.S.7 P3 -100100 15V2F.S.7 8 EA EAM SI 9 NPN2 EAP [psi] 8 0-101 8 EB EBM SI 9 PNP2 EBP [psi] 8 8 FA FAM SI 9 NPN2 FAP [psi] 8 -100100 8 FB FBM SI 9 PNP2 FBP [psi] 8 73m 8 9kPa G 2m V 10 11 12 C2 2 B C4 4 N1 1/8 N3 5/32 K 12 L2 2 L4 4 LN1 1/8 LN3 5/32 10 ZFAZFBZFC 11 10 - No.ZB-OM00301 / 1 01 1 / 02 2 S / 1 S 12 12 PV PD 2 PD PVPD 01 Rc1/8 M5 M50.8PVPD 01N

Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: C6 (ø6 One-touch Fitting, Metric)

Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: C4 (ø4 One-touch Fitting, Metric)

Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: N9 (ø5/16" One-touch Fitting, Inch)

Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: N7 (ø1/4" One-touch Fitting, Inch)

Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 600mm, Maximum Length for L-type, Manual Override: Non-locking Push Type, A,B Port: ø6 One-touch Fitting, Metric, Thread Type: -, Bracket: -

Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 600mm, Maximum Length for L-type, Manual Override: Non-locking Push Type, A,B Port: ø4 One-touch Fitting, Metric, Thread Type: -, Bracket: -

Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 600mm, Maximum Length for L-type, Manual Override: Non-locking Push Type, A,B Port: ø5/16" One-touch Fitting, Inch, Thread Type: -, Bracket: -

Actuation: 2-Position Single, Electrical Entry: Terminal Type, Lead Wire Length: 600mm, Maximum Length for L-type, Manual Override: Non-locking Push Type, A,B Port: ø1/4" One-touch Fitting, Inch, Thread Type: -, Bracket: -

MY1B m2 m3 Moment (Nm) MY1M M1 = F1 x L1 F1 M2 = F2 x L2 M3 = F3 x L3 F3 F2 MY1C L2 L1 L3 MY1H 4. Accuracy Mechanically jointed rodless cylinders do not guarantee traveling parallelism. When accuracy in traveling parallelism and intermediate stroke position is required, please contact SMC sales representatives.

PB45] 0 [dB] [Hz] [Hz] [Hz] -40.0 -24.1 -18.1 -14.5 -12.0 -10.1 0 1 2 3 4 5 6 7 8 9 A B C D E F 00 01 02 03 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 70 66 62 59 56 53 51 48 46 45 43 41 40 38 37 36 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 17.6 16.5 15.6 14.8 14.1 13.4 12.8 12.2 11.7

Note 3) Make sure to indicate the type of solenoid valve when ordering. 3 5 F2 (When double solenoid is mounted) (mm) C2 C3 C1 Model (size) A1 A2 B1 B2 B3 D1 D2 E1 E2 F1 F2 G R CVRB1BW50 CVRB1BW63 CVRB1BW80 CVRB1BW100 120 (136.5) 60 (61) 82.5 78 67 18 36 2.8 12 24 11.5 30 52 (53) 104 (120.5) 25 1/8 102 (136.5) 60 (61) 82.5 98 82 18 36 2.8 16 24 11.5 30 52 (53) 104 (120.5) 27.5 1/8 140 (155

Note 3) Make sure to indicate the type of solenoid valve when ordering. 3 5 F2 (When double solenoid is mounted) (mm) C2 C3 C1 Model (size) A1 A2 B1 B2 B3 D1 D2 E1 E2 F1 F2 G R CVRB1BW50 CVRB1BW63 CVRB1BW80 CVRB1BW100 120 (136.5) 60 (61) 82.5 78 67 18 36 2.8 12 24 11.5 30 52 (53) 104 (120.5) 25 1/8 102 (136.5) 60 (61) 82.5 98 82 18 36 2.8 16 24 11.5 30 52 (53) 104 (120.5) 27.5 1/8 140 (155

Note 3) Make sure to indicate the type of solenoid valve when ordering. 3 5 F2 (When double solenoid is mounted) (mm) C2 C3 C1 Model (size) A1 A2 B1 B2 B3 D1 D2 E1 E2 F1 F2 G R CVRB1BW50 CVRB1BW63 CVRB1BW80 CVRB1BW100 120 (136.5) 60 (61) 82.5 78 67 18 36 2.8 12 24 11.5 30 52 (53) 104 (120.5) 25 1/8 102 (136.5) 60 (61) 82.5 98 82 18 36 2.8 16 24 11.5 30 52 (53) 104 (120.5) 27.5 1/8 140 (155

Load mass (kg) m1 m2 Moment (Nm) m3 M3 = F3 x L3 F3 F2 M1 = F1 x L1 F1 M2 = F2 x L2 L2 L1 L3 Calculation of Guide Load Factor 1) Maximum load mass (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (collision speed = 1.4a) for (3).

SY SYJ SX VK VZ VF VFR VP7 VP4 VQ VQ4 VQZ VQD VZS VFS VS VS7 < >: AC type and TV approved type Dimensions (mm) L n Equation L1=16n+53, L2=16n+73 n: Station (Max. 24) 24 437 457 487.5 498 23 421 441 462.5 473 22 405 425 450 460.5 21 389 409 437.5 448 20 373 393 412.5 423 19 357 377 400 410.5 18 341 361 387.5 398 17 325 345 375 385.5 16 309 329 350 360.5 15 293 313 337.5 348 14 277 297 325

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX Load weight (kg) Dm1 -X 20m2 m3 Moment (Nm) Data M3=F3 x L3 F3 F2 M1=F1 x L1 F1 M2=F2 x L2 L2 L1 L3 1.

F2: The force that is ceated by the port A pressure (PA) that passes through the feedback passage and acts on the spool surface, and the spring force. OFF state { A R1 (Exhaust air) P B (Supply air) F1 < F2 condition: See figure q. ON state { { Immediately after turning on F1 > F2: See figure e.

Actuation: A (4-Position Dual 3 Port Valves, N.C./N.C.), Electrical Entry: TT (Terminal Type), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8), Thread Type: N (NPT)

Actuation: 3 (3-Position Closed Center), Electrical Entry: TT (Terminal Type), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: Non-locking Push Type, A,B Port: 01 (1/8), Thread Type: N (NPT)