Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).

HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).

Data No.1 8 02 0106 sent. 9 01 02 004B 0001 01 02 01 Acquires the INP signal information.

To connect a drain discharge pipe, use a pipe with a minimum bore of 10, and a maximum length of 5 m. Avoid using a riser pipe.

Poriing No. of Ports 'xx" M84010-02 Ta"NPTFSide l l M84011-02 7a" NPTF Side: Y.r" Bottom A & B 1 3 MB 4210-02 %"NPTFSid(2); % Botlom(5) 7 t 5 Manifolds *(OptionsT & P Only) Part No. Poding No.of Ports "xx" Subplates .

Required ventilation rate [m3/min] Model Heat radiation amount [kW] Differential temp. of 3C between inside Differential temp. of 6C between inside and outside of installation area HRR010-A Approx. 2 40 20 HRR012-A Approx. 2 40 20 HRR018-A Approx. 4 70 40 HRR024-A Approx. 5 90 50 HRR030-A Approx. 6 100 60 HRR050-A Approx. 10 140 70 and outside of installation area Voltage dV dt = Voltage

Size: 1/8, Thread: M Thread, Rc(PT), Port Size: 1/4, Accessory: None, Option 1: 6 [Nylon Bowl (Including Sight Dome)], Option 2: C [Bowl Guard (Size 2000 Only)]

With functions narrowed down, 2 independent temperature control systems have been achieved with only a single compressor , a single pump , and a single tank .

Select between two values 2-A or 1-A using the + and keys. The value 2-A indicates a double acting actuator and 1-A a single acting actuator. To conclude press the ?

Option Applicable model 10-/21-AF20-A 10-/21-AF30-A 10-/21-AF40-A 10-/21-AF40-06-A 10-/21-AF50-A 10-/21-AF60-A Bracket assembly Note 2) AF52P-050AS AF22P-050AS AF32P-050AS AF42P-050AS AF42P-070AS Note 2) Assembly includes a bracket and 2 mounting screws. 1069-1 A Air Filter 1021-AF-A Dimensions AF20-A AF30-A to 40-06-A 10211021T N S J M U D J M U D S N T Air Preparation Equipment Pressure

Note 3) in part numbers for a round pressure gauge indicates a pipe thread type. No indication is necessary for R; however, indicate N for NPT. Please contact SMC regarding the pressure gauge supply for both MPa and psi unit specifications. Note 4) in part numbers for a round pressure gauge indicates a type of connection thread.

Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.

Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.

Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: RZ (R + Z)

Body Size: 20, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 02 (1/4), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Standard

Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Body Size: 20, Thread: F (G), Port Size: 02 (1/4), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: 6C (w/Bowl Guard, Nylon Bowl), Semi-Standard 2: Standard

Min. Dripping Flow Rate(l/min): 15, Oil Storage Capacity(cm3): 25, Case: [Nylon] Nylon Case, Inlet Side Connection Type: G, Inlet Side Plumbing Thread Nominal: 1/4, Outlet Side Connection Type: G, Outlet Side Plumbing Thread Nominal: 1/4, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 20, Accessory: Without optional mounting

Body Size: 20, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 01 (1/8), Mounting: None, Semi-Standard, Body Size 10: 6 (Nylon Bowl), Semi-Standard, Body Size 20: C (Bowl Guard), Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 20, Thread: F (G), Port Size: 02 (1/4), Mounting: B (Bracket), Semi-Standard, Body Size 10: 6 (Nylon Bowl), Semi-Standard, Body Size 20: C (Bowl Guard), Semi-Standard, Body Size 30, 40, 50 & 60: Standard