SMC Corporation of America
Elite Part Number Search
Search Results "AL20-F02-3-D"

CU Minimum Stroke for Auto Switch Mounting (mm) D-A7lH, A80H D-F7lW, J79W D-A79W D-F7l, J79 D-F7BA, F7NT D-F7lF CQS D-A7l D-A80 D-A73C D-A80C Number of auto switches D-F7lV D-J79C D-F7lWV CQ2 MU 2 pcs. 5 10 15 15 1 pc. 5 5 10 15 Construction Component Parts No.

Port size Type Symbol Cylinder side In the side of solenoid valve M5 01 02 03 04 F01 F02 F03 F04 U10/32 N01 N02 N03 N04 Elbow 2 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 G 1/8 G 1/4 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Control 0 1 Meter-out Meter-in 15-9-89 16 Construction AS2200

Panel mount adapter ZS-46-B Panel mount adapter + Front protection cover ZS-46-D Lead wire with connector ZS-46-3L 3-core, 2 m, Non-waterproof (Without waterproof cover) Front protection cover ZS-27-01 D Panel mount adapter + Front protection cover ZS-46-D R1/8 Piping adapter ZS-46-N1 NPT1/8 Piping adapter ZS-46-N2 9 3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20

ASV Inch size M1 L3 L2 AK Applicable tubing O.D. d D1 ASS L6 D2 L1 ASR D4 L4 H ASF (Hexagon width across flats) (Hexagon width across flats) D4 D3 A1 L5 A2 L6 T Inch Size Model H D1 D2 D3 D4 L1 L2 L3 L4 L5 L6 A1 A2 M1 T d 1/8" 5/32" 3/16" 1/4" 3/16" 1/4" 5/16" 1/4" 5/16" 3/8" 1/4" 5/16" 3/8" 1/4" 5/16" 3/8" 3/8" ASD230F-U10/32-01T ASD230F-U10/32-03T ASD230F-U10/32-05T ASD230F-U10/32-07T

Message frame . 3-7 3.9 Function code . 3-9 3.10 Checksum calculation method . 3-9 3.10.1 LRC(ASCII) . 3-9 3.10.2 CRC(RTU) .3-10 3.11 Explanation of function codes . 3-12 3.11.1 Function code: 04 Reading multiple registers .3-12 3.11.2 Function code: 06 Writing registers.3-13 3.11.3 Function code: 16 Writing multiple registers .3-15 3.12 Negative response . 3-16 3.13 Register map . 3-18

Both ends of the communication connection (the end nodes) need to be connected to the higher level computer. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.

phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -20 3-phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) -40 3-phase 380 to 415 VAC (50/60 Hz) Set temp. range 5 to 35C Set temp. range 5 to 35C Set temp. range 5 to 35C Temp. stability 0.1C Temp. stability

Applicable Body Size All All 31, 41 31, 41 Symbol Nil B* C D Port Size 1/4 3/8 1/2 *Note: Bracket is not assembled and is supplied loose at time of shipment.

Applicable Body Size All All 31, 41 31, 41 Symbol Nil B* C D Port Size 1/4 3/8 1/2 *Note: Bracket is not assembled and is supplied loose at time of shipment.

HRS Output setting example Output 1: Temperature rise Output 2: Pressure rise Output 3: Operation status (start, stop, etc.)

HEA e Return piping assembly r Barrel nipple (Size: 3/4 inch) (4 pcs.) IDH t Union (Size: 3/4 inch) (4 pcs.) y Sealant tape u Operation Manual 115 HRS100/150 Series y Snow Protection Hood Snow protection hood for air-cooled chiller.

Pump 1.1 kW Compressor + Fan + Others 4 kW (For air-cooled type) (For air-cooled type) Fan Pump Fan Pump HRZ 3. Inverter pump Triple inverter 3.

Industrial Filters 407 Series AR(K) Replacement Procedure of Diaphragm 3 3.

Note) 200 V type only. 400 V type is provided with an earth leakage breaker as standard. 20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 40 3-phase 380 to 415 VAC (50/60 Hz) HRZ Specifications HRZD Model HRS090-Wl-20-l HRS090-Wl-40-l Cooling method Water-cooled refrigeration Refrigerant R410A (HFC) Refrigerant charge kg 1.15 Control method PID control Ambient temperature1 C 5 to

cores x 14 AWG (2.0 mm2), 3 m Electrical system Applicable earth leakage breaker capacity Note 7) A 15 Rated operating current (50/60 Hz) Note 3) A 7.1/7.8 For option -T: 7.8/8.4 7.1/7.8 For option -T: 7.8/8.4 Rated power consumption (50/60 Hz) Note 3) kVA 0.53/0.54 For option -T: 0.62/0.62 0.63/0.63 For option -T: 0.72/0.72 Dimensions Note 8) mm W377 x D435 x H615 For option -T: W377 x D500

A C MTS D-F9W, D-M9 D-A93 D-A90, D-A96 D-M9V, D-F9WV Bore size (mm) CXSJ15 to 32 B D A 15.5 25.5 31.5 39 40 49 D 9.5 7 0 3 5 5.5 C 9.5 19.5 25.5 33 34 43 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 A 15.5 25.5 31.5 39 40 49 A 19.5 29.5 35.5 43 44 53 C 11.5 21.5 27.5 35 36 45 D 5.5 3 4 7 9 9.5 D 8 5.5 1.5 4.5 6.5 7 B 6 9 11 11.5 B 0.5 3 10 13 15 15.5 C 13.5 23.5 29.5 37 38 47 C 11 21 27 34.5 35.5

(same side) D-A9, A9V 50 8 9.5 8 D-A9/A9V Reed switch 1 or 2 pcs. (different sides) D-M9N/M9P/M9B 15 3 3 3.5 2 pcs. (same side) D-F9NW/F9PW/F9BW 55 5 5 4.5 D-M9N/M9P/M9B 1 or 2 pcs. (different sides) D-F9BAL 15 5 6 5 2 pcs. (same side) The operating range for the MGZP series is under examination. 55 Solid state switch D-F9NW/F9PW/F9BW 1 or 2 pcs. (different sides) 15 2 pcs.

regulator IN port SRF Booster regulator IN port C C ITV EXH: C EXH: C IC (A) (B) Tank OUT port Rc 3/4 (A) D (B) OUT OUT 355 ITVH 256 256 205 4 x 13 4 x 13 ITVX 50 50 150 150 500 PVQ 250 250 824 (mm) VY1 Drain port Rc 1/4 A 531 570 494 527 576 B 444 479.8 444 479.8 479.8 C Rc 3/8 Rc 1/2 Rc 3/8 Rc 1/2 Rc 1/2 D Note) 519 543 Booster regulator model VBA20A VBA40A VBA22A VBA42A VBA43A VBA

+0.3 0 1 (P) 3 (R) C +0.5 0 4-Rc 1/4, 3/8 4 (B) B 0.1 Max. panel thickness D (mm) A 3.2 3.2 3.2 B 40 51 64 C 35 41 51 D 3.5 6 8 VH200 VH300 VH400 5-8-13 8 Series VH Dimensions: Panel Mounted VH41-02 to 04 VH41-06 ( ): Long handle type ( ): Long handle type 2 (A) 4 (B) 4 (B) 2 (A) 25 (32) 107.5 19 102 3 (R) 1 (P) 3 (R) 1 (P) 88 102 89 4-6.6 4-6.6 88 81 Courtesy of Steven Engineering, Inc.