1/8, 1/4 2(A) port 19.5 12 40.5 2 x 4.2 (For mounting) 11.2 30 18.5 1/8, 1/4 3(R) port 1/8 12(PA) port 2A NO 35 43 NC 12 12 3R 1P NC (1/8) 12(PA) port 12 6.7 58.2 18.5 65.2 60 59 24 X 12 M5 x 0.8 (Breathing hole) 19.5 39 1/8, 1/4 1(P) port For vacuum/VPA344V-101 02 A B 1/8, 1/4 2(A) port 19.5 12 40.5 2 x 4.2 (For mounting) 1/8, 1/4 3(R) port 18.5 11.2 30 2A NO 35 43 NC 12 3R 1P NC 1/8 12(
Min. Dripping Flow Rate(l/min): 40, Oil Storage Capacity(cm3): 55, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: G, Inlet Side Plumbing Thread Nominal: 3/8, Outlet Side Connection Type: G, Outlet Side Plumbing Thread Nominal: 3/8, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 30, Accessory: Without optional
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Mounting: None, Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 40, Thread: F (G), Port Size: 03 (3/8), Mounting: None, Semi-Standard, Body Size 10: 3 (Drain Cock), Semi-Standard, Body Size 20: R (Flow Direction: Right to Left), Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 40, Thread: G, Port Size: 3/8, Mounting: None, Semi-Standard, Body Size 10: Drain Cock, Semi-Standard, Body Size 20: Flow Direction: Right to Left, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
HRX-OM-Q026-V Operation Manual Installation Operation Original Instructions Thermo Chiller HRSH Series HRSH100-A-20HRSH100-A-40HRSH100-A-20-S HRSH150-A-20HRSH150-A-40HRSH150-A-20-S HRSH200-A-20HRSH200-A-40HRSH200-A-20-S HRSH250-A-20HRSH250-A-40HRSH250-A-20-S HRSH300-A-20HRSH300-A-40HRSH100-W-20HRSH100-W-40HRSH100-W-20-S HRSH150-W-20HRSH150-W-40HRSH150-W-20-S HRSH200-W-20HRSH200-W-40HRSH200
Installation at indoor site 1 In case of facility having a large installation area (that can vent the air naturally) Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2 In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
In case the mounting orientation is not horizontal, a system with a pressure regulating circuit on the lower side is recommended. (It is also effective to shorten start-up delay in rising and for energy conservation.) 12CY1R/3R Caution 1. Pay attention to the cylinder mounting surface.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
Facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air vent on a wall at a low level.
P1 P1 P1 M5 -7VEX-OMO0001 (PE) Best Pneumatics No. () VEX1333-03 G36-4-01 -8VEX-OMO0001 P1 P1 02A 3R (VBA1-10) 3R () PE 3R PE 2A / (VBA1-10) P1 O PE 3R 02A 3R 2A / 2A -9VEX-OMO0001 Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without