SMC Corporation of America
Elite Part Number Search
Search Results "AL40-04B-8-A"

) The flow rate necessary to operate a 50 cylinder at a speed of 100mm/s is 12l/min.

F NB NC K H S + Stroke ZZ + Stroke NA I 3 (mm) Effective thread length (mm) IA (tolerance) Bore size (mm) Stroke range (mm) A B1 B2 D F GA GB H H1 H2 I K MM P S NN N NA NB NC ZZ -0.020 -0.053 -0.020 -0.053 -0.025 -0.064 -0.025 -0.064 20 18 13 26 10 16 12 8 41 5 8 30 5 M8 x 1.25 1/8 81 M22 x 1.5 13 26 19 15 138 23 f8 15.5 to 800 25 22 17 32 12 16 12 8 46 6 8 32 5.5 M10 x 1.25 1/8 81 M24 x

Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).

40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example

HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).

Cable size Crimped terminal on the thermo-chiller side Applicable model HRS100-A -20HRS100-W -204 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 30 A M5 HRS150-A -20HRS150-W -2040 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable R8-5) R8-5 A HRS100-A -40HRS100-W -403-phase 380 to 415 VAC (50/60

If the actual flow rate is lower than this, install a bypass piping. Note 8) To be prepared by user. A specified earth leakage breaker is installed for option B [With earth leakage breaker] and B1 [With earth leakage breaker with handle].

30 20 Applicable earth Note 8) Sensitivity of leak current mA 30 Rated operating current Note 5) A 15 8 Rated power consumption Note 5) kW (kVA) 4.6 (5.2) 5.0 (5.6) Noise level (Front 1 m/Height 1 m) Note 5) dB (A) 66 Accessories Alarm code list stickers 2 pcs.

No anchor bolt is included. 77 A HRS090 Series Standard Type Cooling Capacity HRS090-A-20/40 (50 Hz) HRS090-A-20/40 (60 Hz) 12 12 10 10 Ambient temperature 32C Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 40C Ambient temperature 40C 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 Circulating fluid temperature

Body Size: 40, Thread: Rc, Port Size: 1/2, Mounting: w/Bracket, Bowl: Metal Bowl w/Level Gauge, Lubricant Exhaust Port: w/o Drain Cock, Flow Direction: Left to Right, Pressure Unit: Pressure Unit: MPa; Temp Unit: °C

Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Mounting: B (w/Bracket), Bowl: 8 (Metal Bowl w/Level Gauge), Lubricant Exhaust Port: w/o Drain Cock, Flow Direction: Left to Right, Pressure Unit: Pressure Unit: MPa; Temp Unit: °C

Min. Dripping Flow Rate(l/min): 50, Oil Storage Capacity(cm3): 135, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: Rc, Inlet Side Plumbing Thread Nominal: 1/2, Outlet Side Connection Type: Rc, Outlet Side Plumbing Thread Nominal: 1/2, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 40, Accessory: With Bracket

Body Size: 40, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 04 (1/2), Mounting: B (Bracket), Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Case: [Resin] Polycarbonate Case, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL20-A, AL30-A, AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Sight dome assembly

Case: -, Drain Exhaust: -, Case Guard: -, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Lubrication plug assembly

Case: [Metal] Metal case, Drain Exhaust: [Not Provided] No Drain Cock, Case Guard: With level gauge, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly

Case: [Metal] Metal case, Drain Exhaust: [Manual] With Drain Cock, Case Guard: With level gauge, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly

Case: [Metal] Metal case, Drain Exhaust: [Not Provided] No Drain Cock, Case Guard: None, Specification: Applicable part number: AL40-A, AL40-06-A, AL50-A, AL60-A, Type: Case assembly