(port B) Manual override R1 R2 P A B 14 11 9 50 62 38 50 62 A 12 Prewired connector (M12) (L approx. 500) R1 P R2 A B 13 13 2-Rc1/8 2-6.5 Mounting hole Indicator light 42.5 42.5 3-Rc1/4, 3/8 (P, A, B) 34 34 Bottom port drawing SMC (ports A, B) 93 12 Y 25 (port X) 5 3 37 22 14 25 14 1 25 9 25 2-Rc3/8 Ports R1, R2 Rc1/4, 3/8 Port P Rc1/8 Port Y (PE) 2-Rc1/4, 3/8 Ports A, B Rc1/8 Port X (PE
fitting 5/16" One-touch fitting SV1000 SV1000 10 One-touch fitting 3/8" One-touch fitting SV2000 SV2000 12 One-touch fitting 3/8" One-touch fitting SV3000 SV3000 12 One-touch fitting 3/8" One-touch fitting 3/8" One-touch fitting NPT 1/4 NPT 3/8 NPTF 1/4 NPTF 3/8 Ports 2, 4 mixed SV4000 SV4000 NPT 3/8 Rc 3/8 G 3/8 NPTF 3/8 In case of mixed specification (M), indicate separately on a manifold
Size: 1/2, Thread: M Thread, Rc(PT), Port Size: 3/4, Accessory: Bracket, Option 1: Metal Bowl w/Level Gauge, Option 2: -
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
Cable size Crimped terminal on the thermo-chiller side Applicable model HRS100-A -20HRS100-W -204 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 30 A M5 HRS150-A -20HRS150-W -2040 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable R8-5) R8-5 A HRS100-A -40HRS100-W -403-phase 380 to 415 VAC (50/60
If the actual flow rate is lower than this, install a bypass piping. Note 8) To be prepared by user. A specified earth leakage breaker is installed for option B [With earth leakage breaker] and B1 [With earth leakage breaker with handle].
30 20 Applicable earth Note 8) Sensitivity of leak current mA 30 Rated operating current Note 5) A 15 8 Rated power consumption Note 5) kW (kVA) 4.6 (5.2) 5.0 (5.6) Noise level (Front 1 m/Height 1 m) Note 5) dB (A) 66 Accessories Alarm code list stickers 2 pcs.
No anchor bolt is included. 77 A HRS090 Series Standard Type Cooling Capacity HRS090-A-20/40 (50 Hz) HRS090-A-20/40 (60 Hz) 12 12 10 10 Ambient temperature 32C Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 40C Ambient temperature 40C 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 Circulating fluid temperature
25 25 X (PE) port 1/8 A, B port 2-/4, 3/8 9 1/8 R1, R2 port 2-3/8 P port 1/4, 3/8 Y(PE) port 2 position double : VQ7-6-FG-D double (Reverse pressure): VQ7-6-YZ-D 3 position closed center : VQ7-6-FHG-D exhaust center : VQ7-6-FJG-D pressure center: VQ7-6-FIG-D 155 145 68.5 86.5 76.5 68.5 50 50 50 50 13 (A port) 13 (B port) 13 (A port) 13 (B port) Manual override Manual override A B A B B B
Port A size Port B size Number of Port A Porting Port A Port B Model 4 8 10 12 Rc(PT) Rc(PT) 6 8 10 6, R(PT) 6, R(PT) 6, R(PT) 8 ,R(PT) 8, R(PT) 8, R(PT) 10, R(PT) 10, R(PT) 10, R(PT) 6 8 10 4 6 6 8 One-touch fitting One-touch fitting 6, 10 KM11 1 4 3 8 Rc(PT)female thread 6, 10 One-touch fitting KM12 One-touch fitting One-touch fitting 3 KM13 1 8 1 4 3 8 1 8 1 4 3 8 KM11 One-touch fitting
M5 x 0.8, NPTF 1/8, M5 x 0.8 ZX ejector mounted type: M5 x 0.8 Port size R 1/8, M5 x 0.8, NPTF 1/8, M5 x 0.8 Enclosure IP40 Note 1) For vacuum operation, a momentary pressure of 0.5MPa will not be a problem.
25 25 X (PE) port 1/8 A, B port 2-/4, 3/8 9 1/8 R1, R2 port 2-3/8 P port 1/4, 3/8 Y(PE) port 2 position double : VQ7-6-FG-D double (Reverse pressure): VQ7-6-YZ-D 3 position closed center : VQ7-6-FHG-D exhaust center : VQ7-6-FJG-D pressure center: VQ7-6-FIG-D 155 145 68.5 86.5 76.5 68.5 50 50 50 50 13 (A port) 13 (B port) 13 (A port) 13 (B port) Manual override Manual override A B A B B B
(mm) M5 M5 4 4 Port size R Port size R 1 8 1 8 6 6 1 4 1 4 8 8 3 8 3 8 10 10 1 2 1 2 12 12 Flame Resistant Type (UL-94 Standard V-0 equivalent) 1(P): One-touch fitting 2(A): One-touch fitting 1(P): Male thread 2(A): Male thread 2(A) 2(A) Port size R Applicable tubing O.D. (mm) 1 8 1 4 3 8 1 2 1(P) 4 6 8 10 12 1(P) Applicable tubing O.D.
roller 45.5 29.2 (A) 2 Symbol 2 port 8 R port (3 port only) P.T.
VFS Y 5 3 37 25 22 14 1 VS4 25 25 3/8-2 port 3, 5 port 1/4, 3/8 1 port 9 1/4, 3/8-2 port 2, 4 port 1/8 12 port 1/8 14 port VQ7 VV71-(M Connector type) EVS VFN 100 80 100 80 37 23 U-side 9 2n-1/4, 3/8 14 9 U-side 15 PE port Indicator light Manual override R 4.5 R 4.5 53.5 53.5 9 9 38 9 B B 20 14 12 P = 43 A P = 43 PA 23 A A B B 14 12 A PA PA L1 L2 L2 L1 B B B 14 12 A A A A B 14 A A PA B B
Inch size 3/8" 5/16" 1/4" 5/16" 1/4" 5/32" 1/8" Flow rate (l/min (ANR)) OUT 1000 680 440 480 420 210 150 IN OUT IN High pressure Effective area (mm2) 15.2 10.4 6.7 7.3 6.4 3.2 2.3 Note) Flow rate is the value measured under a pressure of 0.5 MPa and a temperature of 20C.
Construction Weight Operating pressre Ambient and fluid temperature Contacts Port size (Nominal size) VR3200-01 VR3201-01 Closed terminal (with protect case) 130g 260g 5 to 60C (No freezing) 0.1 to 1.0MPa 1ab Rc(PT) (6A) 1 8 Micro Switch Rating Non-inductive load (A) Inductive load (A) Resistance load Inductive load Light load Electric motor load N.O. N.O. N.C. N.C. N.O. N.O. N.C. N.C.