4 Note 1) Cotter pin should be used together with a flat washer.
Nozzle Diameter: 18 (ø1.8mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: F03 (Screw-in G3/8), VAC: F03 (Screw-in G3/8), EXH: F03 (Screw-in G3/8)
Body Size: -, Thread: -, Port Size: -, Mounting: -, Bowl: -, Lubricant Exhaust Port: -, Flow Direction: -, Pressure Unit: -
3 Hexagon socket head taper plug Slide Bearing Felt Holder Ball bushing 16 20 25 32 40 50 63 80 100 MGP50-A-PS MGP63-A-PS MGP80-A-PS MGP100-A-PS MGP16-A-PS MGP20-A-PS MGP25-A-PS MGP32-A-PS MGP40-A-PS Set of nos. above @3, @4, @5 @6, @7, @8 Set of nos. above @3, @4, @5 @6, @7, @8 !4 !5 !6 !7 Except 16 Except 16 Seal kit includes @3 to @8.
D-Z7m D-Z8m D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV D-A9m D-A9mV D-F5m D-J59 D-F59F D-F5NT D-A5m D-A6m D-A59W D-G39 D-K39 D-A3m D-A44 D-P3DWA D-P4DW Bore size A B A B A B A B A B A B A B A B A B A B 32 10 8 6 4 6.5 4.5 11.5 9.5 0 0 4 2 0 0 3.5 1.5 5.5 3.5 3 1 40 9 9 5 5 5.5 5.5 10.5 10.5 0 0 3 3 0 0 2.5 2.5 4.5 4.5 2 2 50 10 9 6 5 6.5 5.5 11.5 10.5 0 0 4 3 0 0 3.5 2.5 5.5 4.5 3 2 63 10
: C EXH: C Spare port Rc1/2 (A) AMR D D (A) (B) (B) OUT OUT 305 Tank OUT port Rc1/2 ARM 216 216 180 4 x 13 4 x 13 50 50 ARP Drain valve 100 100 Drain port Rc1/4 IR-A 200 200 400 700 678 IR Booster regulator model A B C D VBA20A 481 394 Rc3/8 VBA40A 520 429.8 Rc1/2 VBA22A 444 394 Rc3/8 469 VBA42A 477 429.8 Rc1/2 493 IRV The length may be longer than the specification if the plugs mounted
8 @0 !7 !9 i @2 q r y #0 $0 $2 w A C B A section $1 !2 !2 $6 !0 u @5 !6 @1 !1 $7 o $8 #4 @6 #9 @8 #6 #7 e $4 B section C section #1 #2 !
D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-P5DWL Bore size (mm) A B A B A B A B A B A B A B 32 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 CL 40 1 3.5 1.5 4 0 0.5 9.5 12 4.5 7 2 4.5 0 0.5 50 1.5 4 2 4.5 0 1 10 12.5 5 7.5 2.5 5 0 1 CL1 63 1.5 4 2 4.5 0 1 10 12.5 5 7.5 2.5 5 0 1 80 5.5 7 6 7.5 2.5 4 14 15.5 9 10.5 6.5 8 2.5 4 MLGC 100 5.5 7 6 7.5 2.5 4 14 15.5 9 10.5 6.5 8 2.5
Body size 1 2 3 4 M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard Port size Type Symbol Cylinder side In the side of solenoid valve M5 01 02 03 04 F01 F02 F03 F04 U10/32 N01 N02 N03 N04 Elbow 2 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 G 1/8 G 1/4 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT
N01 Connection NPT 1/8 N02 Connection NPT 1/4 Port size N03 Connection NPT 3/8 Option specifications Application Size Symbol N04 Connection NPT 1/2 IRV3000 IRV2000 IRV1000 F01 Connection G 1/8 01 02 03 04 1/8 1/4 3/8 1/2 F02 Connection G 1/4 F03 Connection G 3/8 F04 Connection G 1/2 Accessory (Option) Part No. Part no.
With gasket is provided as standard. 1/8, 1/4 standard 3/8 standard 1/2 standard Port size Symbol Cylinder side In the side of solenoid valve M5 01 M5 x 0.8 R 1/8 M5 x 0.8 Rc 1/8 Rc 1/4 Note 1) Elbow 02 R 1/4 Rc 3/8 Note 2) 03 04 F01 Rc 3/8 Rc 1/2 G 1/8 G 1/4 Note 1) R 3/8 R 1/2 R 1/8 F02 R 1/4 G 3/8 Note 2) Caution Control F03 F04 U10/32 N01 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 Note 1)
Port size Type Symbol Cylinder side In the side of solenoid valve M5 01 02 03 04 F01 F02 F03 F04 U10/32 N01 N02 N03 N04 Elbow 2 M5 x 0.8 R 1/8 R 1/4 R 3/8 R 1/2 R 1/8 R 1/4 R 3/8 R 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 M5 x 0.8 Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 G 1/8 G 1/4 G 3/8 G 1/2 10-32 UNF NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2 Control 0 1 Meter-out Meter-in 15-9-89 16 Construction AS2200
Metric size Inch size Model Port size Pilot port 6 8 10 12 1/4" 5/16" 3/8" 1/2" ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 ASP330F-N01 ASP430F-N02 ASP530F-N03 ASP630F-N04 R 1/8 M5 x 0.8 R 1/4 Rc 1/8 R 3/8 Rc 1/8 R 1/2 Rc 1/4 R 1/4 G 1/8 R 3/8 G 1/8 R 1/2 G 1/4 NPT 1/8 10-32 UNF NPT 1/4 NPT 1/8 NPT 3/8 NPT 1/8 AS NPT 1/2 NPT 1/4 Note
Nozzle Diameter: 15 (ø1.5mm), Vacuum Pressure: L (-48 kPa: ZH05 to 13D*A; -66 kPa: ZH15 to 20D*A), SUP: F02 (Screw-in G1/4), VAC: F03 (Screw-in G3/8), EXH: F03 (Screw-in G3/8)
Nozzle Diameter: 18 (ø1.8mm), Vacuum Pressure: S (-90 kPa), SUP: F03 (Screw-in G3/8), VAC: F03 (Screw-in G3/8), EXH: F03 (Screw-in G3/8), Accessories: N (w/o Bracket, w/o Silencer)
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
Cable size Crimped terminal on the thermo-chiller side Applicable model HRS100-A -20HRS100-W -204 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 30 A M5 HRS150-A -20HRS150-W -2040 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable R8-5) R8-5 A HRS100-A -40HRS100-W -403-phase 380 to 415 VAC (50/60