Cooling Capacity HRS100-A -20/40(50 Hz) HRS100-A -20/40(60 Hz) 14 14 12 12 Ambient temperature 90F (32C) Cooling capacity [kW] Cooling capacity [kW] 10 10 Ambient temperature 90F (32C) Ambient temperature 104F (40C) Ambient temperature 104F (40C) 8 8 6 6 4 4 Ambient temperature 113F (45C) Ambient temperature 113F (45C) 2 2 0 0 41 [5] 50 [10] 59 [15] 68 [20] 77 [25] 86 [30] 95 [35] 41 [5]
Cooling Capacity HRS100-A-20/40(50 Hz) HRS100-A-20/40(60 Hz) 14 14 12 12 Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 10 10 Ambient temperature 40C Ambient temperature 32C Ambient temperature 40C 8 8 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature
Recommended Parameter Values [LEF] LEFS25T6 LEFS32T7 LEFS40T8 Lead symbol H A B H A B H A B Series Lead 20 12 6 24 16 8 30 20 10 Parameter *1,*2 Para. Initial value Recommended value No.
No anchor bolt is included. 77 A HRS090 Series Standard Type Cooling Capacity HRS090-A-20/40 (50 Hz) HRS090-A-20/40 (60 Hz) 12 12 10 10 Ambient temperature 32C Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 40C Ambient temperature 40C 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 Circulating fluid temperature
Remote modeOpen A The time of FLT alarmClose FLT Operation stop FLT alarm status signal B The time of FLT alarmOpen A The time of WRN alarmClose WRN Continuing operation WRN alarm status signal B The time of WRN alarmOpen ALM Alarm status signal A The time of alarmClose B The time of alarmOpen RDY TEMP READY signal A TEMP READY statusClose B TEMP READY statusOpen A EnabledClose FREZ Anti-freezing
NO 8 No.VT307N-OMV0001 [3R] *N.O.[1P] 9 No.VT307N-OMV0001 No. 1ISO VG 32 [3R] *N.O.[1P] 1. 2. 3. 4. 5. 6. 7. 10 No.VT307N-OMV0001 VS 0120-837-838 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer
B 19.5 25 29.5 C 6.5 7 14.5 A 8 8 8 8 10 10 Model MGQ32 MGQ40 MGQ50 MGQ63 MGQ80 MGQ100 Detailed figure of a section Detailed figure of b section a a a b MGQ32 to 50 MGQ63 to 100 8-20-10 11 Compact Guide Cylinder Series MGQ Proper Auto Switch Mounting Position (Detection at stroke end) Minimum Stroke for Auto Switch D-Z7/Z80 D-Y5/Y6/Y7(V) D-Y7W(V) 1 pc. 2 pcs. 5 10 5 5 10 15 Auto switch D-Z7
2 to 20 stations D side: 2 to 10 stations U side: 2 to 10 stations M Mixed Nil Standard length (Specify a longer rail than the standard length.)
Operating Range Auto switch model Bore size (mm) 20 25 32 40 D-C7/C-80 D-C73C/C-80C 8 10 9 10 D-B5/B64 8 10 9 10 D-B59W 13 13 14 14 D-H7, D-H7W H7BAL/H7NF 4 4 4.5 5 D-H7C 7 8.5 9 10 Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.) There may be the case it will vary substantially depending on an ambient environment.
the CXSW15-10 and the CXSW15-20 have a groove cut out for installing auto switches.
Fluid 10-12 10-11 10-10 10-9 10-8 10-7 10-6 10-5 10-4 10-3 10-2 10-1 1 101 102 103 104 105 106 107 108 109 Pa 1) Type of fluid Vacuum piping direction: if the system uses a vacuum pump, we ask that you install the vacuum pump on the secondary side. Also, install a filter on the primary side, and be careful that no foreign material is picked up.
Thread dia. 6 8 10113 10 a o a a M4 x 0.7 16 a a o a o o a M5 x 0.8 20 o a a a o a M6 x 1.0 25 a a o o o MB x 1.25 32 o o a o o M'l0 x 1 .25 zcDuKc T.
Thread dia. 6 8 10113 10 a o a a M4 x 0.7 16 a a o a o o a M5 x 0.8 20 o a a a o a M6 x 1.0 25 a a o o o MB x 1.25 32 o o a o o M'l0 x 1 .25 zcDuKc T.
In principle, this function counts each time there is a rise or fall in either of the A or B phase pulses. 2 1 Amplification/ Interpolation circuit Counter A phase B phase Magnetic resistance element Piston rod Magnet Count 1 2 3 4 5 6 7 8 9 10 .
If the kinetic energy obtained is no greater than the absorbable kinetic energy shown in the table above, the life of the cushion seal will be 10 million cycles or more. 3 Standard Type Double Acting: Single Rod Series MB1 Construction !3r !5uq yet!6!9!2!8 !4w !7 i o A A' Cylinder tube sectional view A-A' !0 !1 Parts list No. q w e r t y u i o !0 !1 !2 !3 No. !4 !5 !6 !7 !8 !
3r!5uq yet !9!2!8!4w !7 !6 i o A CJ1 CJP CJ2 CM2 A Cylinder tube sectional view A-A CG1 !1!0 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB Component Parts No. q w e r t y u i o !0 !1 !2 !3 No.
3r!5uq yet !9!2!8!4w !7 !6 i o A CJ1 CJP CJ2 CM2 A Cylinder tube sectional view A-A CG1 !1!0 MB Component Parts No. q w e r t y u i o !0 !1 !2 !3 No.
the bolt a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a o a a a a a a a a a a a a a a a a a a a a r a o a a AF Air filterTBody Descrplon Applicable l\,4eia bow AF10 to 60 Nylon bow AF10 to 60 I\4elai bowlwth eve gauge AF30 lo 60 Thread type With bowl guard AF2O Nole 1) Drarn guide s NPT114 (appicable 10 AF30 to 60), and the exhaust poir ior aUo drarn comes wlh
M 9 _ 6, 10, 16,20 Note 3) aOlvlark ng s electroless niDkel pated, provided 6, 10, 16,20 20,25,32 a a a a a a a a a a a a a a a a a a a o a a a a a a a a a a a a o a i a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a Hexaona ock nut {Wdth across flat) Electroless nicke lr ated ^r""".af T I I ^"" l\4e1r c icable tube O.
, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com R P 27 30 (2) 7 12.7 VR A 9.2 VH 2 15 (Bracket) 10 VHS 11 Base mounted: SYJA34-M5 14 5 10 Manual override (Non-locking) 2-3.2 (External pilot port) (For mounting) 17 3 (For solenoid valve) 2.5 M3 x 0.5 (Pilot port) A 11 17.5 1.5 21 27 30 28.5 P R 1 (Breathing hole) 13 5 8.6 10 (P , A,