Body Size: 30, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 3/8, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 30, Type: Regulator Type, Pipe Thread: NPT, Port Size: 3/8, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
Body Size: 40, Type: Regulator Type, Pipe Thread: NPT, Port Size: 3/8, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: Units Selection Function, Manual Override: Non-locking Push Type
MODEL FLOW PORT B C D WEIGHT ELEMENT A Die-cast Aluminum with chromate treatment No screw threads or tie rods are required therefore removal and replacement of element is made quick and easy (AFF) Differential Pressure indicator Internal autodrain Built-in push-to-connect fitting on drain (AFF) NPT in in in in lb (cfm) 6.26 AFF2B-N02C-T 10 1/4 2.48 0.39 1.46 0.84 AFF-EL2B 6.78 AFF4B-N03C-T
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 03 (3/8), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 04 (1/2), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 04 (1/2), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: F (G), Port Size: 04 (1/2), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: N (NPT), Port Size: 04 (1/2), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: H (without Attachments), Port Size: 00 (without Attachments), Normally Open, Closed: D (N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: M (EXA1/ITV: SI Unit Only), Manual Override: G (Non-locking Push Type)
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: G, Port Size: 1/2, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: SI Unit Only, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: NPT, Port Size: 1/2, Normally Open, Closed: N.C., Normally Closed, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: SI Unit Only, Manual Override: Non-locking Push Type
Body Size: 40, Type: Electro-Pneumatic Regulator Type, Pipe Thread: G, Port Size: 1/2, Normally Open, Closed: N.O., Normally Open, Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: EXA1/ITV: SI Unit Only, Manual Override: Non-locking Push Type
Body Size: 40, Type: A (Electro-Pneumatic Regulator Type), Pipe Thread: R (Rc), Port Size: 04 (1/2), Normally Open, Closed: C (N.C., Normally Closed), Protocol: PN [PROFINET, OPC UA (When Wireless Adapter is Connected: Wireless Base)], Unit: K (EXA1/ITV: Units Selection Function), Manual Override: E (Push-turn Locking Type, Manual)
Air management system, FRL COMBO, P27, 0.80000 lb
This is a legacy product, and replaced byAW30-N03C-Z-B, FILTER REGULATOR, MODULAR, AIRLINE EQUIPMENT, AW MASS PRO, EC, AW MASS PRO 3/8 MODULAR (NPT), 1.25332 lb
This is a legacy product, and replaced byAF40-N03C-Z-A, FILTER, MODULAR, AIRLINE EQUIPMENT, AF MASS PRO, EC, AF MASS PRO 3/8 MODULAR (NPT), 1.32277 lb