(Refer to the table below) U D U D Cylinder port size Kit designation/Electrical entry/Cable length 3/8 NPTF 1/2 NPTF Bottom ported 1/2 NPTF Rc3/8 Rc1/2 Bottom ported Rc1/2 Mixed sizes Note) 03T 04T BT 03 04 B CM F L Kit (D sub connector kit) Kit (Lead wire kit) Note) Indicate on a manifold specification sheet in case of mixed sizes.
Applicable speed controller Direct connection type AS120 Piping type AS1001F Direct connection type AS220 Piping type AS2001F etc. J M5 x 0.8 4.3 DM6 x 1 7.3 -X M8 x 1.25 17.5 20Data 3. Please observe the specified torque limits when tightening screws to mount the attachment.
Applicable speed controller Direct connection type AS120 Piping type AS1001F Direct connection type AS220 Piping type AS2001F etc. J M5 x 0.8 4.3 DM6 x 1 7.3 -X M8 x 1.25 17.5 20Data 3. Please observe the specified torque limits when tightening screws to mount the attachment.
Applicable speed controller Direct connection type AS1200-M5 Piping type AS1001F Piping type AS2001F etc. At the maximum stroke Adjustment range Maximum adjustment range Max tightening torque Nm Model Bolt MIW12D-12D M3 x 0.5 0.88 MIS12D-D MIW20D-20D MIS20D-D M5 x 0.8 4.3 23 Series MIW/MIS Specific Product Precautions 2 Be sure to read before handling.
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Conditions Base mounted Tubing bore x Length Speed controller Silencer Series CJ2 Series CM2 6 x 1 m AS2301F-06 AN120-M5 AS2001F-06 Series CJ2 Series CM2 4 x 1 m AS1301F-04 AN120-M5 Body ported Tubing bore x Length Speed controller Silencer SYJ3140-M5 SYJ3120-M3 1-5-5 6 Series SYJ3000 How to Order Light/Surge voltage suppressor Bracket
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Conditions Body ported Series CJ2 Series CM2 Series MB, CA1 T0425 x 1 m Tube bore x Length VQ0149-C4 Speed controller AS2001F-04 AN103-X233 Silencer Tube bore x Length T0604 x 1 m 30 41 VQ11 -C6 Speed controller AS3001F-06 Silencer AN103-X233 T0806 x 1 m Tube bore x Length VQ2149-C8 Speed controller AS3001F-08 Silencer AN200-KM8
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VZ1120--M5 (Piping: 6 x 1 m) VZS VFS VS4 AS2001F-06/AN120-M5 AS2301F-M5-06/AN120-M5 Speed controller/Silencer It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle
Load factor: ((Load weight x 9.8) /Theoretical force) x 100% Conditions Series CJ2 Series CM2 6 x 1 m AS2301F-06 AN120-M5 AS2001F-06 Base mounted Tubing bore x Length Speed controller Silencer Body ported Tubing bore x Length Speed controller Silencer Series CJ2 Series CM2 4 x 1 m AS1301F-04 AN120-M5 SYJ3140-M5 SYJ3120-M3 2 Series SYJ3000 How to Order Light/surge voltage suppressor Bracket
Load factor: ((Load weight x 9.8)/Theoretical force) x 100% Conditions Base mounted Tubing bore x Length Speed controller Silencer Series CJ2 Series CM2 6 x 1 m AS2301F-06 AN120-M5 AS2001F-06 Series CJ2 Series CM2 4 x 1 m AS1301F-04 AN120-M5 Body ported Tubing bore x Length Speed controller Silencer SYJ3140-M5 SYJ3120-M3 1-5-5 Series SYJ3000 How to Order Light/Surge voltage suppressor Bracket
Applicable Tube OD: 07 (1/4"), Option: J (For AS1001F, AS1002F, AS2001F, AS2002F )
Applicable Tube OD: 04 (Ø4), Option: J (For AS1001F, AS1002F, AS2001F, AS2002F )
Applicable Tube OD: 01 (1/8"), Option: J (For AS1001F, AS1002F, AS2001F, AS2002F )
Applicable Tube OD: 03 (5/32"), Option: J (For AS1001F, AS1002F, AS2001F, AS2002F )
Applicable Tube OD: 06 (Ø6), Option: J (For AS1001F, AS1002F, AS2001F, AS2002F )
Applicable Tube OD: 23 (Ø3.2), Option: J (For AS1001F, AS1002F, AS2001F, AS2002F )
L2 L3 M1 Weight Model Applicable D1 D2 L1 L2 L3 M1 Weight Tube OD : d Max Min gf (Inch) (Metric) Tube OD : d Max Min gf 7.8 10 41.1 4.4 14.5 1/8 23.4 20.6 5.8 NAS1001F 3.2 7.8 41.1 4.4 23.4 20.6 14.5 5.8 8.9 42.3 4.9 5/32 24 21.2 6.2 AS1001F 10 4 8.9 42.3 4.9 24 21.2 6.2 14.5 8.9 43.8 5.2 5/32 32.6 27.6 11.4 15.5 6 11 47 6 25 22.2 7.2 11.8 16.5 11.4 50 6.2 NAS2001F 3/16 33.6 28.6 17.1 AS2001F
X Port size) Sysytem Figure Silencer System Solenoid valve Speed controller 4 X M5 6 X M5 6 X 1/8 6 X M5 AS1301F-M5-04 A SYJ3000 M5 X 0.8 (S = 1.8mm2) AS1301F-M5-06 B q AN120-M5 (S=5mm2) AS2301F-01-06 C 6 X M5 AS2001F-06 D w 1.2-9 Series SYJ3000 How to Order Bracket Light and surge voltage suppressor Configuration S Z R U Without light and surge suppressor With surge suppressor With light
www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE N233 2.73 SOLENOID VALVES SERIES NVFS H O W T O O R D E R NVFS4000 NVFS 4 F 0 P O S I T I O N P O R T S I Z E 1 2 Position Single 2 2 Position Double 3 3 Position Closed Center 4 3 Position Exhaust Center 5 3 Position Pressure Center 6 3 Position Perfect Without Subplate 03T 3/8 NPTF *04T.
This is a legacy product, and replaced byVFS5300-3FZ-04T VFS5000 SOL VALVE 4/5 PORT. VALVE SOL/PILOT 110VAC *LQA. VALVE. VFS5000 BASE MT 1/2. 4.356 lb. RF.
Stations: 6 Stations, Port Size: 04T (NPTF1/2), Electrical Entry Direction: D (D Side Entry), Cable Length: 0 (0.6m Cable), Option 1: None, Option 2: W (Dust Poof IP65 Rated)