(with no freezing or heat cycle) Ambient temperature 0 to 100C (with no freezing or heat cycle) Pilot air pressure 0.2 to 0.5MPa Proof pressure 0.75MPa Mounting orientation Horizontal (with mounting hole on the bottom) Weight 2.1kg (without foot) PA: Standard Assembled and packaged in a standard environment Assembling environment PAP: Clean room Assembled and double-packaged in clean-room
Table symbols : Can be used : Depends on conditions X: Cannot be used Compatibility is indicated for fluid temperatures of 100C or less. Consult P/A regarding fluids other than the above. Consult P/A regarding operating conditions. 1.12-6
(-4 to 212F) Ambient temperature Note 1) 10 to 60 (14 to 140F) (with no freezing) 10 to 100C (14 to 212F) Fluid temperature Splash-proof (equivalent to IP65) Enclosure Location without corrosive or explosive gases Environment 0 (with oil pressure) Valve leakage cm3/min Unrestricted Mounting position 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC, 230VAC (50/60Hz) 100VAC, 200VAC, 220VAC, 230VAC
There is a possibility of plasticizer and other materials precipitating on the tube surface and detracting from the cleanliness level of the room. 40 to +100C, Water: 0 to +50C (No freezing) Nylon 12 Operating temperature Note 2) Material Note 1) Refer to the Printing/Fluid.
(mm) 2.5 3 4 4.5 6 7.5 9 13 2.18 3.48 4.57 6.99 9.56 Black (B) Max. operating pressure (MPa) White (W) TIA Series Red (R) Blue (BU) T1613 Yellow (Y) Green (G) T0403 Other metric size Nominal size (inch) 5 32" 5 16" 1 4 3 8 " 3 16" 1 8 " 1 2 " " Nominal size (mm) 0.0 40 20 0 20 40 60 80 100 Specifications 3.2 Operating temperature (C) Fluid Air/Water 20C or less 40C 60C 80C 100C 3.3 2.3 1.65
The VC enclosure is IP65 equivalent.Multipurpose valve for oil, Withstand pressure: 5.0MPa, Ambient temperature: -20 to 60C (Standard) -20 to 100C (High temp.), Fluid temperature: -10 to 60C (Standard) -10 to 100C (High temp.), Valve leakage cm¦/min: 0 (with oil pressure), VALVE, COMPACT FOR OIL, VALVE, VC* VALVE, 2-PORT SOLENOID, 2A, VC* NO SIZE RATING, 0.97003 lb
(Equivalent to IP44) 90C 47C (50C) or less Splashproof/ Low jetproof type (JIS C 0920) 35C (40C) or less 100C Note) ( ) For IF32 To protect the microswitch, ambient temperature must be lowered when the fluid temperature exceeds 70C.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.5 m Dry Suction lift 4 m Wet VX3 0 to 100C (Not be frozen. Do not apply heat cycle.) Operating fluid temperature 0 to 100C (Not be frozen. Do not apply heat cycle.)
) Steam system (Boiler water) Steam system (Condensate) Insulation oil Parachloroetylene Brake oil Water (up to 99C) Ethyl alcohol Ethylene glycol Caustic soda (25% ) Gas oil Silicon oil Fuel oil (up to 60C) Fuel oil (up to 100C) Steam system (Boiler water) Steam system (Condensate) Insulation oil Naphtha Parachloroetylene Brake oil Water (up to 99C) Note) If using for other fluids, please
(-4 to 212F) Ambient temperature Note 1) 10 to 60 (14 to 140F) (with no freezing) 10 to 100C (14 to 212F) Fluid temperature Splash-proof (equivalent to IP65) Enclosure Location without corrosive or explosive gases Environment 0 (with oil pressure) Valve leakage cm3/min Unrestricted Mounting position 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC, 230VAC (50/60Hz) 100VAC, 200VAC, 220VAC, 230VAC
High purity chemical valve, 3 port, Operating pressure: 0 ~ 0.5 MPa , Fluid temperature: 0 to 100C , Port sizes: 1/4, Threads: Rc, NPT FLUOROPOLYMER VALVES and REG. FLUOROPOLYMER, VALVE. VALVE. FLUOROPOLYMER. 0.22088 lb. 2I.
Although the variation in the operating range differs with the cylinder on which the auto switch is mounted, a temperature change of 100C will roughly result in the maximum of 20% reduction in the overall operation range.
Thread type Nil Rc N NPT* * Semi-standard Suffix Low temperature (30 to 60C) High temperature* (10 to 100C) External parts copper-free Nil T V L V S V ST V V SL V V * With pressure gauge type: Max. 80C.
Finger material Dust cover material DFinger material Action 20Action The packing class has been revised to adopt thermal proof materials for use at high temperature of up to 100C. Possible to select the auto switch mounting side.
MHF Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Without magnet EPDM for seals, Fluorine grease Fluorine grease MHL -X4 -X5 -X50 -X53 -X63 -X79 -X79A -X81A Refer to How to Select the Applicable Model on page 700. Refer to pages 700 and 701 for the details on effective holding force and allowable overhanging distance.
Controller Specifications LC7R-K11A LC7R-K12A Model Regeneration method Heat exchange method based on resistance Regenerative resistance capacity 40W Regenerative operation voltage 180V 380V Regenerative absorption unit Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) Protective circuit To PLC,
Controller Specifications LC7R-K11A LC7R-K12A Model Regeneration method Heat exchange method based on resistance Regenerative resistance capacity 40W Regenerative operation voltage 180V 380V Regenerative absorption unit Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) Protective circuit To PLC,
Controller Specifications LC7R-K11A LC7R-K12A Model Regeneration method Heat exchange method based on resistance Regenerative resistance capacity 40W Regenerative operation voltage 180V 380V Regenerative absorption unit Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) Protective circuit To PLC,
Finger material Dust cover material DFinger material Action 20Action The packing class has been revised to adopt thermal proof materials for use at high temperature of up to 100C. Possible to select the auto switch mounting side.
The packing class has been revised to adopt heat resistant materials for using it at a high temperature of up to 100C.