Size: S (Small Flow Style), Control Valve: 2 (Metering Valve), Combination Valve: 2 (Stop Valve), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Suffix: U1 (Convertor Unit/for CC63 (To be Integrated in CCT63))
Size: S (Small Flow Style), Control Valve: 2 (Metering Valve), Combination Valve: 2 (Stop Valve), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Suffix: U1 (Convertor Unit/for CC63 (To be Integrated in CCT63))
Size: S (Small Flow Style), Control Valve: 2 (Metering Valve), Combination Valve: 3 (Skip Valve), Voltage: 1 (100VAC), Electrical Entry: G (Grommet), Suffix: U1 (Convertor Unit/for CC63 (To be Integrated in CCT63))
Size: S (Small Flow Style), Control Valve: 2 (Metering Valve), Combination Valve: 3 (Skip Valve), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Suffix: U1 (Convertor Unit/for CC63 (To be Integrated in CCT63))
Size: S (Small Flow Style), Control Valve: 3 (Speed Controller For Minimal Flow (CCVS Only)), Combination Valve: 3 (Skip Valve), Voltage: 1 (100VAC), Electrical Entry: D (DIN Terminal), Suffix: U1 (Convertor Unit/for CC63 (To be Integrated in CCT63))
Size: S (Small Flow Style), Control Valve: 2 (Metering Valve), Combination Valve: 0 (None), Voltage: w/o Combination Valve, Electrical Entry: Air Operated Style, Suffix: U1 (Convertor Unit/for CC63 (To be Integrated in CCT63))
Size: S (Small Flow Style), Control Valve: 2 (Metering Valve), Combination Valve: 2 (Stop Valve), Voltage: 0 (Air Operated Style), Electrical Entry: Air Operated Style, Suffix: U1 (Convertor Unit/for CC63 (To be Integrated in CCT63))
Size: S (Small Flow Style), Control Valve: 1 (Speed Controller), Combination Valve: 1 (Stop Valve/Skip Valve), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Suffix: U1 (Convertor Unit/for CC63 (To be Integrated in CCT63))
Switch 5 to 24VDC Load current (1C): 100mA, Internal voltage drop: 0.8V or less Load current (1C): 40mA, Internal voltage drop: 0.4V or less Specifications Note) When the work load exceeds 15kg, the speed may be limited. Contact SMC in this case.
Switch 5 to 24VDC Load current (1C): 100mA, Internal voltage drop: 0.8V or less Load current (1C): 40mA, Internal voltage drop: 0.4V or less Specifications Note) When the work load exceeds 15kg, the speed may be limited. Contact SMC in this case.
Switch 5 to 24VDC Load current (1C): 100mA, Internal voltage drop: 0.8V or less Load current (1C): 40mA, Internal voltage drop: 0.4V or less Specifications Note) When the work load exceeds 15kg, the speed may be limited. Contact SMC in this case.
SY3000-54-2C(-Q) SY3000-54-1C(-Q) SY5000-54-1C(-Q) SY7000-54-1C(-Q) Assembly part no.
For each increase of 1C in the inlet air temperature, the outlet air atmospheric pressure dew point increases by approximately 0.8C.
For other models, when the tube length is 5 meters or less, a rise of the outlet air atmospheric pressure dew point will be 1C or less.
Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30 IDG50 0 m 20 1 m 19 3 m 17 5 m 16 Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. Refer to pages 14-19-28 to 29. Construction Refer to pages 14-19-30 to 31.
Tubing size (O.D. x I.D.) mm: 12 x 9 IDG30 IDG50 0 m 20 1 m 19 3 m 17 5 m 16 Note) In cases other than above model numbers, if the tube length is 5 m or less, an increase of the outlet air at the atmospheric pressure dew point will be 1C or less. Refer to pages 14-19-28 to 29. Construction Refer to pages 14-19-30 to 31.
SY3000-54-2C(-Q) SY3000-54-1C(-Q) SY5000-54-1C(-Q) SY7000-54-1C(-Q) Assembly part no.
Company Bs PLC I/O card Connector pin assignment (pin layout) Company As PLC I/O card Connector pin assignment (pin layout) Change of PLC manufactures (Company A to Company B) + + + + 2F 2E 2D 2C 2B 2A 11 13 15 17 19 1B 1D 1F 21 23 25 27 29 2B 2D 2F 29 28 27 26 25 24 23 22 21 20 + + 19 18 17 16 15 14 13 12 11 10 + + 1F 1E 1D 1C 1B 1A 10 12 14 16 18 1A 1C 1E 20 22 24 26 28 2A 2C 2E General
solenoid/ 3 position SY9000 SY9000-37-1B Series SY9000-37-2B 9 SY9000 Single solenoid with spacer assembly SY9000-37-3B Type of actuation Double solenoid/3 position with spacer assembly 1 2 position single 2 2 position double SY9000-37-4B 3 3 position closed center For 110VAC (115VAC) 4 3 position exhaust center Specification Single solenoid Double solenoid/ 3 position SY9000 SY9000-37-1C
Assembly No. 8 One-touch fitting 8 One-touch fitting SY3000-55-1B SY3000-54-1C 6 One-touch fitting SY3000-54-2C Series SY5000 Series SY5000 Port size Assembly No. Port size Assembly No. 10 One-touch fitting SY5000-55-1B 10 One-touch fitting SY5000-54-1C Series SY7000 Series SY7000 Port size Assembly No.