Model/Specifications MHT2-32D MHT2-40D MHT2-50D MHT2-63D Model Bore size (mm) Applicable auto switch Bracket no.
MHL2-40D MHL2-40D1 MHL2-40D2 SMHL2C, #4 SMHL2C, #5 SMHL2C, #6 (#6+#7) 2.2-12
CQSXB12-5D CQSXB20-30D CQ-M5 x 50 L CQ-M3 x 25 L 50 25 CQSXB00-10D CQSXB00-35D x 55 L x 30 L 55 30 CQSXB00-15D CQSXB00-40D x 60 L x 35 L 60 35 6.5 6.5 Example) CQ-M3x25 L 4 pcs.
(PAT.PEND) Over length L(mm) Gripping moment Weight (g) Bore size (mm) Model (Nm) L MHW2-20D 68 300 20 0.30 MHW2-25D 510 25 0.73 78 905 MHW2-32D 32 93.5 1.61 2135 MHW2-40D 117.5 40 3.70 5100 Auto switch mounting at 4 locations MHW2-50D 154 50 8.27 At the pressure of 0.5 MPa MHZ Two finger types available.
1 37 16 18 25 25 26 28 38 39 30 Width across flats 17 (2 locations) 38 79 (117) K 20 Width across flats 19 (2 locations) 4 13 4 38 18 18 18 48 2 x M12 x 1.75 (Piston rod thread) 4 x M12 x 1.75 through (Thread for mounting attachment) 28 When open G When open F 28 60 86 (mm) J 72 130 170 H 348 466 546 G 288 406 486 F 188 246 286 E 80 138 178 D 164 222 262 B C 116 174 214 112211221122MHL2-40D
Pressure 0.7 MPa 0.6 MPa Pressure 0.7 MPa MHZA2, MHZ2, MHZL2 250 0.6 MPa 0.6 MPa 0.6 MPa 20 Gripping force (N) 0.5 MPa 0.5 MPa Gripping force (N) 0.5 MPa 0.5 MPa 200 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa 15 150 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MPa 10 100 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MPa 5 50 L 0 10 20 30 40 50 60 0 20 40 60 80 100 Gripping point L (mm) Gripping point L (mm) MHZ2-16D/MHZL2-16D MHZ2-40D
Pressure 0.7 MPa 0.6 MPa Pressure 0.7 MPa MHZA2, MHZ2, MHZL2 250 0.6 MPa 0.6 MPa 0.6 MPa 20 Gripping force (N) 0.5 MPa 0.5 MPa Gripping force (N) 0.5 MPa 0.5 MPa 200 0.4 MPa 0.4 MPa 0.4 MPa 0.4 MPa 15 150 0.3 MPa 0.3 MPa 0.3 MPa 0.3 MPa 10 100 0.2 MPa 0.2 MPa 0.2 MPa 0.2 MPa 5 50 L 0 10 20 30 40 50 60 0 20 40 60 80 100 Gripping point L (mm) Gripping point L (mm) MHZ2-16D/MHZL2-16D MHZ2-40D
MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ Auto switch 2.7-5 Series MHT2 Auto Switch Installation Auto Switch Hysteresis Model Hysteresis (Max.) angle 3 3 3 3 MHT2-32D MHT2-40D MHT2-50D MHT2-63D D-A7, D-A8: Rail mounting type D-Fl9V: Direct mounting type are shown above.
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 mm, Stroke: 40 mm, Rod End Thread: With Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 mm, Stroke: 40 mm, Rod End Thread: With Thread, Auto Switch: M9NW--Solid State, 2 color Indication, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: M (1m)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93V,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9B,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9BW,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9P,
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: M9PWV
Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø16 mm, Stroke: 40 mm, Rod End Thread: With Thread, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: Z (5m), Number: S (1 pc.)
Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 mm, Stroke: 40 mm, Rod End Thread: With Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Option: -
Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 mm, Stroke: 40 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Option: -