Magnet: D (Built-in), Mounting: G (Rear Flange), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 250mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Pre-wired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector
Magnet: D (Built-in), Mounting: D (Double Clevis), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Pre-wired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector
Magnet: D (Built-in), Mounting: L (Foot), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Magnet: Built-in, Mounting: Double Clevis, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: NPT, Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9PA--Solid State, Water Resist., 3 Wire PNP, Horizontal, Lead Wire or Pre-wired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or
Magnet: Built-in, Mounting: Foot, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: NPT, Stroke: 700mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
, 800 25 3000 32 40 3000 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 5000 63 Note 1) Long stroke type (XB11) applies to the strokes exceeding 2000 mm.
Standard Strokes [mm] Bore size [mm] Standard stroke [mm] 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Note) Intermediate strokes not listed above are produced upon receipt of order.
M9PWV M9PW V V V v v 2-wire 12 V M9BWV M9BW M9BWV M9BW V V V v v Diagnostic indication (2-color indicator) Relay, PLC Yes 24 V 3-wire (NPN) 5 V, 12 V M9NAV1 M9NA1 M9NAV1 M9NA1 v v V v v IC circuit 3-wire (PNP) M9PAV1 M9PA1 M9PAV1 M9PA1 v v V v v 2-wire 12 V M9BAV1 M9BA1 M9BAV1 M9BA1 v v V v v Grommet Water resistant (2-color indicator) With diagnostic output (2-color indicator) 4
, 800 Non-lubricated exterior (without dust seal) 25 1500 Outside of cylinder tube with hard chrome plated 32 Non-lubricated exterior (with dust seal) 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 1500 40 Switch rails on both sides (with 2 pcs.)
Type Special function Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V 3-wire (PNP) M9PV M9P V V V v v Grommet 2-wire 12 V M9BV M9B V V V v v Connector H7C V V V V Terminal conduit 3-wire (NPN) 5 V, 12 V G39A V IC circuit 2-wire 12 V K39A V Solid state auto switch Relay, PLC Yes 3-wire (NPN) 5 V, 12 V M9NWV M9NW V V V v v IC circuit 3-wire (PNP) M9PWV M9PW
1,000 900 800 700 600 500 400 300 200 100 0 1,000 900 800 700 600 500 400 300 200 100 0 Mass of transferred object m [kg] Mass of transferred object m [kg] Upper limit 80 Operating range 80 Operating range Upper limit Lower limit Lower limit 10 20 30 40 0 10 20 30 40 0 Transfer speed [m/min] Transfer speed [m/min] 592 Model Selection RS2H Series Lateral Load and Operating Pressure The greater
MHF Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Without magnet EPDM for seals, Fluorine grease Fluorine grease MHL -X4 -X5 -X50 -X53 -X63 -X79 -X79A -X81A Refer to How to Select the Applicable Model on page 700. Refer to pages 700 and 701 for the details on effective holding force and allowable overhanging distance.
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Indicator light Type Electrical entry Pre-wired connector Wiring (output) Special function Applicable load 0.5 (Nil) 1 (M) 3 (L) 5 (Z) AC DC Perpendicular In-line M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV1 3-wire (NPN) M9N M9P M9B M9NW M9PW M9BW M9NA1 5 V, 12 V IC circuit Reed auto switch Solid state auto switch 3
The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized
25 150 Up to 700 1500 32 150 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.
Load voltage Lead wire length (m) Applicable load Auto switch model Tie-rod mounting Band mounting Indicator light Wiring (Output) Pre-wired connector Special function Type Electrical entry DC AC 0.5 (Nil) 3 (L) 5 (Z) 1 (M) M9N M9P M9B G39C K39C M9NW M9PW M9BW M9NA1 G59 G5P K59 G39 K39 G59W G5PW K59W G5BA1 3-wire (NPN) 5 V, 12 V IC circuit Grommet 3-wire (PNP) 24V 12 V 2-wire
25 150 Up to 700 1500 32 150 Up to 1000 40 200 Up to 1000 Note 1) The cylinder performance may not as expected when stroke is longer than recommended stroke even they are available.