Mounting example for D-M9(V), M9W(V), M9A(V). 341
CHSD Series How to Mount and Move the Auto Switch
(Make sure that there is no rotation backlash in the table.) 3 Tighten both adjustment bolts c and d to approx. 45. Note 1) Tighten both adjustment bolts c and d to approx. 45. Note 1) 4 Lock adjustment bolts c and d with fixing nuts. Note 2) Lock adjustment bolts c and d with fixing nuts.
BQ-1 BQ-2 BQ2-012 Weight (g) 1.5 1.5 5 259
CHQB/CHQWB Series How to Mount and Move the Auto Switch
Single round shaft: ClRA1BT Double shaft (round shaft, with four chamfers): ClRA1BJ Double round shaft: ClRA1BK D D D H H H H UU UU M N 0 0.2 G D L 0 0.2 [mm] [mm] [mm] Size D (g6) H Size D (g6) G H M N UU L Size D (g6) H UU 30 8 25 50 15 36 63 17 41 80 20 50 100 25 60 30 8 6 25 10 8 75 7.8 50 15 11 36 20 15 118 14 63 17 13 41 22 17 139 16 80 20 15 50 25 20 167 19 100 25 19 60 30 25 202 24
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Magnet: Built-in Magnet, Mounting: Head Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 250mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: -, Made to Order: -
Magnet: Built-in Magnet, Mounting: Head Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 250mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Made to Order: -
Magnet: Built-in Magnet, Mounting: Head Flange, Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 250mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m, Number: -, Made to Order: -
Magnet: D (Built-in Magnet), Mounting: G (Head Flange), Tube Material: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 250mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)
D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30
D-M9mW D-M9mA D-M9mV D-M9mWV D-M9mAV U A B [mm] Auto Switch Proper Mounting Position [mm] Auto Switch Mounting Height D-M9m D-M9mV D-M9mW D-M9mWV D-M9mA D-M9mAV A B 12 5 2.5 16 5.5 3 20 6 6 25 6 7.5 32 8 8 40 11 9 50 11.5 11 63 13.5 13.5 80 16.5 18 100 19.5 21 Auto switch model Auto switch model D-M9mV Bore size Bore size U 12 19.5 16 21 20 23 25 24.5 32 28.5 40 31.5 50 36.5 63 43 80 52.5
2-colour display) Grommet D-M9PW(V) -900 Max.40mA Sequence mounting controller Relay Yes DC1028V , 2.5 Tie-rod Sequence (2-colour Grommet D-M9BW(V) -900 40mA mounting controller display) 31 - 2) Precautions for use When installing the auto switch on the 25A-CDS2 series, pay attention to the following. 1.
D-M9V, D-M9WV D-M9A D-M9AV A B W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable
Auto Switch Mounting Height (mm) D-B5 D-B64 D-B59W D-G5 D-K59 D-G5NT D-G5W D-K59W D-G5BA D-G59F Auto switch model D-F5 D-J59 D-F5W D-J59W D-F5BA D-F59F D-F5NT D-Z7 D-Z80 D-Y59 D-Y7P D-Y7BA D-Y7W D-A9 D-M9 D-M9W D-M9A D-A3C D-G39C D-K39C D-A44C D-A9V D-M9V D-M9WV D-M9AV D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-Y69 D-Y7PV D-Y7WV Bore size (mm) Ht Hs 40 50 63 80 100 Hw Hs Ht Hs Ht Hs Ht Hs
D-A7/A80 D-A7H/A80H D-A73C/A80C D-A79W D-P3DW 13 11 11.5 10.5 11 12 D17 7 14.5 6 15.5 5.5 14 6 14 15.5 -X 397 MK Series Auto Switch Proper Mounting Position (Detection at Stroke End) and its Mounting Height D-F79F/F7NT D-A7/A80 D-A73C/A80C D-A7H/A80H D-A79W D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BA/F7BAV B A U 20, 25 20, 25 U B A 32
/Y7PV D-Y7W/Y7WV D-Y7BA D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BA 5 5 5 5.5 5.5 5 5 5 5.5 5.5 Perpendicular electrical entry type and D-Y7BAL cannot be mounted on 16, 20, 50 and 63.