Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 50mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: Standard (Rod End Female Thread, Without thread on 4mm bore), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal
[Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole (standard), Port thread type: Rc, Body Options: -, Auto Switches: A93
[Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket: Through-hole (standard), Port thread type: Rc, Body Options: -, Auto Switches: A93
Same surface Same surface D-A9 D-M9 D-M9W 10 note) 45 45 + 45 (n-2) D-C7 D-C80 10 50 50 + 45 (n-2) D-H7 D-H7W D-H7BAL/H7NF 60 + 45 (n-2) 10 60 D-C73C D-C80C D-H7C 65 + 50 (n-2) 10 65 D-B5/B64 D-G5/K59 D-B59W 75 + 55 (n-2) 10 75 D-B7/B80 D-G79/K79 50 + 45 (n-2) 10 45 Note) For cylinders with 2 auto switches D-A93/M9/M9W.
M9BAV 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire IC circuit 5 V, 12 V Solid state switch Reed switch 12 V Diagnostic indication (2-color indication) IC circuit 5 V, 12 V Relay, PLC Grommet 24 V Yes 12 V Water resistant (2-color indication) IC circuit 5 V, 12 V 12 V 3-wire (NPN equivalent) A96 A96V IC circuit 5 V Yes 24 V Grommet A93
IC circuit A96V A96 5V Yes 24V Grommet A93V A90V A93 A90 100V 100 V or less Relay, PLC 2-wire 12V No IC circuit Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction.
-XC8 to -XC11: Change of Rotation Range (Size: 50 to 100) . -XC30 Fluoro Grease (Size: 30 to 100) . -XC31 to -XC36: Change of Rotation Range and Rotation Direction of Shaft . -XC37 to -XC42: Change of Rotation Range and Angle Adjusting Direction. -XC43 to -XC46: Change of Rotation Range and Angle Adjusting Direction.
(Or None in the Case of No Switch), Stroke Options: XC8 (Adjustable Extension Type)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Built-in magnet 125 to 160 J K With rod boot Copper and Fluorine-free Change of rod end shape Oversized rod cylinder Heat-resistant cylinder (10 to 150C) Cold-resistant cylinder Low speed cylinder (5 to 50 mm/s) Special port position With heavy duty scraper Heat resistant cylinder (0 to 110C) Made of stainless steel Tie-rod, cushion valve, tie-rod nut, etc. made of stainless steel -XC7 -XC8
A water-resistant type cylinder is recommended for use in an environment which requires water resistance. *2 1 m type lead wire is only applicable to D-A93.
V V V V Relay, PLC No 100 V or less A90V A90 V V IC circuit *1 Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. *2 1 m type lead wire is only applicable to D-A93. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ *
However, please contact SMC for water-resistant cylinder of 20 and 25. 2 1 m type lead wire is only applicable to D-A93. 5 m Z (Example) M9NWZ None N (Example) H7CN Solid state auto switches marked with are produced upon receipt of order.
However, please contact SMC for water resistant products of 12 and 16. *2: The D-P3DWA is mountable on bore size 25 to 100. *3:1 m type lead wire is only applicable to the D-A93. *: Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ *:Solid state auto switches marked with are produced upon receipt of order.
IC circuit 5 V, 12 V 3-wire (PNP) Relay, PLC 2-wire 12 V Grommet 5 V, 12 V 24 V 3-wire (NPN) 3-wire (PNP) IC circuit Diagnostic indication (2-color indication) 12 V 2-wire Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) A93L 5 mZ (Example) F9NWZ Since there are other applicable auto switches than listed, refer to page 8-10-22 for details.
This is a legacy product, and replaced byNCQ2A50-40DZ, CYL, COMPACT, NPT *LQA, ACTUATOR, NCQ2 COMPACT CYLINDER, ND, 50MM NCQ2 DOUBLE-ACTING, 1.37720 lb, SeriesModelActionNoteCQ2StandardCQ2Double acting, Single rodExcept with rubber bumper
This is a legacy product, and replaced byNCQ2D40-40DZ, CYL, COMPACT, NPT *LQA, ACTUATOR, NCQ2 COMPACT CYLINDER, MD, 40MM NCQ2 DOUBLE-ACTING, 1.43300 lb, SeriesModelActionNoteCQ2StandardCQ2Double acting, Single rodExcept with rubber bumper
This is a legacy product, and replaced byNCDQ2G63-40DZ, CYL, COMPACT, AUTO-SW, NP *LQA, ACTUATOR, NCQ2 COMPACT CYLINDER, PE, 63MM NCQ2 DBL-ACT AUTO-SW, .00000 lb
This is a legacy product, and replaced byNCQ2L40-40DZ