SMC Corporation of America
Elite Part Number Search
Search Results "CDQSL25-250DCM-M9BWL"

, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: M9BWL

Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: M9BWL

This is a legacy product, and replaced byMGPM40-50Z-M9BWL, CYL, COMPACT GUIDE, SLIDE *LQA, ACTUATOR, MGP COMPACT GUIDE CYLINDER, MM, 40MM MGP SLIDE BEARING, 5.35934 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520025030035040040MGPM40??1.95??2.372.833.253.684.104.534.955.996.857.708.55

This is a legacy product, and replaced byMGPM25-50Z-M9BWL, CYL, COMPACT GUIDE, SLIDE *LQA, ACTUATOR, MGP COMPACT GUIDE CYLINDER, IM, 25MM MGP SLIDE BEARING, 2.98986 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520025030035040025MGPM25?0.95?1.051.161.271.651.922.192.472.743.013.674.214.765.30

This is a legacy product, and replaced byMGPM25-50AZ-M9BWL, CYL, GUIDE W/AIR CUSH,SLIDE BR, ACTUATOR, MGP COMPACT GUIDE CYLINDER, IM, 25MM MGP SLIDE BEARING, 3.68630 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520025030035040025MGPM25?0.95?1.051.161.271.651.922.192.472.743.013.674.214.765.30

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 25mm, Stroke: 35mm, Option: C (Rubber Bumper), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 25mm, Stroke: 200mm, Option: C (Rubber Bumper), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 25mm, Stroke: 250mm, Option: C (Rubber Bumper), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 25mm, Stroke: 30mm, Option: M (Rod End Male Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 25mm, Stroke: 50mm, Option: M (Rod End Male Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 25mm, Stroke: 200mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: 25mm, Stroke: 125mm, Option: C (Rubber Bumper), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches