Lead wire length symbols 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Refer to page 14 for additional details and applicable auto switches other than the above types.
L A93L MXPJ6/Precision Air Slide Table 6 Specifications Theoretical Output How to Order (N) MXPJ6 10 Cylinder bore size (mm) Piston area (mm) 0.2 Cylinder bore size (mm) Port size Fluid Action Operating pressure Proof pressure Operating pressure (MPa) 6 M3 x 0.5 Air Double acting 0.15 to 0.7MPa 1.05MPa 10 to 60C 50 to 500mm/s Rubber bumper Non-lube +1 0 mm Precision Air Slide Table 0.3 0.4
Maximum Load Weight (g) Weight (g) Cylinder stroke (mm) 5 Maximum load weight Model Model 10 15 20 25 30 MXU6 MXU10 MXU16 MXU6 MXU10 MXU16 100 66 72 81 88 97 103 200 115 124 138 147 166 174 400 216 215 251 250 285 300 8-3-3 4 Series MXU Allowable Moment Precautions Allowable moment (Nm) Correction value of moment center position distance (mm) Model Stroke Be sure to read before handling.
This is a legacy product, and replaced byCE1B32-300-A93L, CYL, SCALE, W/CONNECTOR, ACTUATOR, CE1 MISCELLANEOUS SPECIALIZED, LC, 32MM CE1 OTHERS (COMBO), 4.76198 lb
This is a legacy product, and replaced byCHDMF25-300-A93L
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 160mm, Port Thread: Rc, Stroke: 300mm
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 900, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 160mm, Port Thread: Rc, Stroke: 600mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 160mm, Port Thread: Rc, Stroke: 700mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 160mm, Port Thread: Rc, Stroke: 900mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: Built-in, Mounting: Rod Flange, Bore Size: 160mm, Port Thread: Rc, Stroke: 700mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 900, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: Rc, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 160mm, Port Thread: Rc, Stroke: 300mm, Rod Boot: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 160mm, Port Thread: Rc, Stroke: 300mm, Rod Boot: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: F (Rod Flange), Bore Size: 160mm, Port Thread: Rc, Stroke: 300mm, Rod Boot: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m)