SMC Corporation of America
Elite Part Number Search
Search Results "CDUJB10-6D-F8BLS"

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: Without

Non-lube Double acting, Single acting Ambient and fluid temperature Repeatability Maximum operating frequency Lubrication Action Models Gripping force Note 1) Bore size (mm) Opening/ Closing stroke (both sides) mm Symbols: Double acting type Gripping force per finger Effective value N (lbf) Weight g Action Model External gripping force Internal gripping force MHZA2-6D MHZAJ2-6D MHZA2-6S MHZAJ2

SUB.PLATES (SPOm4) JOY CONNECTORS A @epiacrs fd Nuh;rios sa Jr subiraio. 6D'.\ [o @) \9-l 5 POLE 'duir oenins in rh. iunctlon cov.r. Th6 Joy C{.necror ptulde qulck d.l*h por6r ro th sor.n oid(s, on rhe valva. r*o (21 typs ot Joy ConBlors{..va'rabr: A th. i3)wrE.!

60C, Ambient temperature: 32C Water cooled aftercooler Inlet air temperature: 180C Inlet temperature of cooling water: 30C Note 2) Series IDF Inlet air temperature: Saturated at 35C (IDF1D), saturated at 40C (IDF2D to 240D), Ambient temperature: 32C Note 3) Series IDG Inlet air temperature: Saturated at 25C, Ambient temperature: 25C Note 4) Series IDU Inlet air temperature: 60C (IDU3D to 6D

Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 6mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 6mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8B,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8B,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8B,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8N,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8N,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8P,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8P,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: M9P,

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: Z (5m), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: S (1 pc.)