SMC Corporation of America
Elite Part Number Search
Search Results "CHD2FFA63B-350-M9BW"

25-20 stroke 0.84 0.28 0.66 32-25 stroke 1.41 0.60 1.28 40-25 stroke 1.64 0.80 50-25 stroke 2.79 1.27 63-25 stroke 3.48 1.60 80-25 stroke 5.41 2.81 100-25 stroke 9.12 4.48 Overall length *1: Bore size 10 *2: Bore size 15 3 mounting options Top mounting Bottom mounting Bottom mounting 2 Compact Guide Cylinder JMGP Series 12, 16, 20, 25, 32, 40, 50, 63, 80, 100 How to Order JMGPM 25 M9BW

5 Construction Page 7 Dimensions Pages 8 to 11 Auto Switch Installation Examples and Mounting Positions Pages 12, 13 Auto Switch Hysteresis Page 13 Prior to Use Auto Switch Connections and Examples Page 14 Made to Order Pages 15 to 21 How to Mount Air Grippers Page 22 Safety Instructions Back cover 2 Wide Type Parallel Style Air Gripper 10, 16, 20, 25 MHL2 Series How to Order M9BW

Lateral load F = mg [N] (g: Gravitational acceleration = 9.8 [m/s2]) Mass of transferred object m [kg] RSQ RSG Friction coefficient RS2H RS2H RSH P: Operating pressure of the cylinder [MPa] MIW MIS D-X 593 Heavy Duty Stopper Cylinder 50, 63, 80 RS2H Series RoHS How to Order D 30 RS2H 50 L M9BW Bore size 50 63 80 50 mm Port thread type Number of auto switches (auto switch number mounted)

: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire Length(m): 0.5, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto

Cylinder (Tube) Inner Diameter(φ): 200, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: NPT, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto

Auto Switches: M9BW, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Shaft Bearing: Slide bearing, Custom-made Specifications: None

Auto Switches: M9BW, Lead Wire Length(m): 1, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Shaft Bearing: Slide bearing, Custom-made Specifications: None

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: M9BW, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire