Filter regulator series IW prevents moisture and dust in the compressed air line while maintaining pressure at a stable level, in spite of variations of both air consumption and air source pressure.Filter regulator, North American, Bracket and gauge available, Flow rate: 400N /min (at 5kgf/cm of supply pressure), FLOW SWITCH, NPT, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GA, IFW/PFW 3
Filter regulator series IW prevents moisture and dust in the compressed air line while maintaining pressure at a stable level, in spite of variations of both air consumption and air source pressure.Filter regulator, North American, Bracket and gauge available, Flow rate: 400N /min (at 5kgf/cm of supply pressure), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, GB, IFW/PFW 3/4INCH
Filter regulator series IW prevents moisture and dust in the compressed air line while maintaining pressure at a stable level, in spite of variations of both air consumption and air source pressure.Filter regulator, metric, Bracket and gauge available, Flow rate: 400N /min (at 5kgf/cm² of supply pressure), FILTER REGULATOR, FILTER/REGULATOR, 861, 690 lb
Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 400mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: D (Double Clevis), Style: Aluminum Tube, Bore Size: 80mm, Thread: TN (NPT), Stroke: 400mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 400mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: NPT, Stroke: 400mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Air Pressure Lock-up, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: D (Spring/Air Pressure Lock)
Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: T (Center Trunnion), Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 300mm, Option: J [Nylon Tarpaulin, Cushion: Both Sides (Air-hydro has No Cushion)], Lock Operation: E [Spring Lock (Lock Exhaust)]
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: None, Mounting: Center Trunnion, Style: Aluminum Tube, Bore Size: 40mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -