SMC Corporation of America
Elite Part Number Search
Search Results "CVQB40-10M-A93LS-5MZ"

Example: When ordering with an air chuck Lead wire length symbol: 0.5mNil (Example) F9N 3mL (Example) F9NL 5mZ (Example) F9NWZ Auto switches marked "O" are produced upon receipt of order. Note 1) Be careful for the differential of 2-color display type. Refer to "Auto Switch Hysteresis" on page 22.

Electrical entry direction Applicable Electrical entry Indicator Type load Perpendicular F9N F9P F9B F9NV F8N F9PV F8P F9BV F8B 3-wire (NPN) 3-wire (PNP) Solid state (switch) Relay PLC 2-wire 12V Yes Grommet 24V 3-wire (NPN) 3-wire (PNP) F9NWV F9NW Diagnostic indication F9PWV F9PW (2-color display) F9BWV F9BW 2-wire Lead wire length symbols: 0.5mNil (Example) F9N 3mL (Example) F9NL 5mZ

type Thread type 02 2 stations Standard Nil NPT Rc N T F Symbol 24 24 stations NPTF G Option 1 5 2 VV5ZS2-51FD-091-01-MP5 VZS2150-5FZ VZS2250-5FZ Note) Maximum stations 51F 16 stations 51G15 stations 51 24 stations Passage Porting specifications 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common Symbol Port size 1 1 8 01 Rc (Manifold base) (2 position single) 1 5 VV5ZS2-51-071-01-M5 VZS2150-5MZ

type Thread type 02 2 stations Standard Nil NPT Rc N T F Symbol 24 24 stations NPTF G Option 1 5 2 VV5ZS2-51FD-091-01-MP5 VZS2150-5FZ VZS2250-5FZ Note) Maximum stations 51F 16 stations 51G15 stations 51 24 stations Passage Porting specifications 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common Symbol Port size 1 1 8 01 Rc (Manifold base) (2 position single) 1 5 VV5ZS2-51-071-01-M5 VZS2150-5MZ

100V Relay, PLC Grommet Yes 100V Reed switch 2 wire 24V PLC Lights when OFF No 48V, 100V Relay, PLC 100V Port on top Rail on left 4 Diagnostic indication (2 color indicator) Diagnostic indication (2 color indicator) with spatter resistant cable Solid state switch Relay, PLC Yes 2 wire 24V Grommet P5DWB Port on left Rail on top 5 Lead wire length symbols 0.5mNil (Example) P70 3mL P70L 5mZ

Electrical entry direction Applicable Electrical entry Indicator Type load Perpendicular F9N F9P F9B F9NV F8N F9PV F8P F9BV F8B 3-wire (NPN) 3-wire (PNP) Solid state (switch) Relay PLC 2-wire 12V Yes Grommet 24V 3-wire (NPN) 3-wire (PNP) F9NWV F9NW Diagnostic indication F9PWV F9PW (2-color display) F9BWV F9BW 2-wire Lead wire length symbols: 0.5mNil (Example) F9N 3mL (Example) F9NL 5mZ

2-color display) Yes 3-wire (PNP) Relay, PLC 24V 2-wire 12V Water resistant (2-color display) Grommet 5V, 12V With timer 3-wire (NPN) IC circuit With diagnostic output (2-color display) 5V,1 2V 4-wire (NPN) Latch type with diagnostic output (2-color display) F7LF Magnetic field resistant (2-color display) P5DW 2-wire Lead wire length symbols 0.5mNil (Example) A73C 3mL (Example) A73CL 5mZ

C73C 5mZ EX.) C73CZ 3m L C73CL N C73CN In addition to the models in the above table, there are some other auto switches that are applicable. For more information, refer to page 2. 1 Series CBJ2 Specifications Series CJ2 air cylinder is equipped with end lock function.

Mounting: Through Hole, Bore Size: 32mm, Stroke: 10mm, Option: Rod End Male Thread, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: Light/Surge Voltage Suppressor, Manual Override: -, Piping

Mounting: B (Through Hole), Bore Size: 32mm, Stroke: 10mm, Option: M (Rod End Male Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector With Lead Wire), Surge Voltage Suppressor: Z (Light/Surge Voltage Suppressor)

ON OFF 4 38 4 4.11.3 (LE--) (1) 10m 10m MR-BKS1CBLM-A1-L MR-BKS1CBLM-A2-L MR-BKS1CBLM-A1-H MR-BKS1CBLM-A2-H LE-CSBDC24V (3) DC24V MBR EMG (EMG) (2) (MBR) (ALM) AWG20 B1 (1) AWG20 B2 1. 2. (B1B2) 3.

10m 10m LE-CSMMR-PWS1CBLM-A1-L MR-PWS1CBLM-A2-L MR-PWS1CBLM-A1-H MR-PWS1CBLM-A2-H CNP3 AWG 19() AWG 19() AWG 19() AWG 19() AWG 19() AWG 19() U V W U V W M AWG 19(/) AWG 19(/) (b) 10m 10m 2m 11.5 2m 2m MR-PWS1CBL2M-A1-L MR-PWS1CBL2M-A2-L MR-PWS1CBL2M-A1-H MR-PWS1CBL2M-A2-H LE-CSM50m 50m MR-PWS2CBL03M-A1-L MR-PWS2CBL03M-A2-L CNP3 AWG 19() AWG 19() AWG 19() AWG 19() AWG 19() AWG 19()

Note 3) Refer to page 261 for the fixation of DIN rail mounting type manifold. 1 2 Stations 3 U side D side DIN Rail Option Nil 0 3 Direct mounting Without DIN rail (with bracket) Manifold base (5 stations) SS5Y3-10M-05D-C6 For 3 stations Specify a longer rail than the total length of specified stations. 24 For 24 stations SS5Y3-10M-05D-C6 1 set (Type 10 5-station manifold base part no

Port size Port size With check valve Without check valve With check valve Without check valve KKA3P-01M -02M -03M KKA4P-02M -03M -04M KKA6P-03M -04M -06M KKA7P-04M -06M -10M KKA8P-06M -10M -12M KKA9P-10M -12M -14M KKA3P-01M-1 -02M-1 -03M-1 KKA4P-02M-1 -03M-1 -04M-1 KKA6P-03M-1 -04M-1 -06M-1 KKA3S-01M -02M -03M KKA4S-02M -03M -04M KKA6S-03M -04M -06M KKA7S-04M -06M -10M KKA8S-06M -10M -12M

Driver Servo amp lifier (Note 7) (Note 7) (Note 4, 9) (Note 2) 24VDC CN1 CN1 1 DICOM 9 ALM Trouble (Note 6) RA1 13 DOCOM 10 SA Speed reached (Note 3, 5) Forced stop RA 2 EM1 SON RES 8 4 3 (Note 9, 11) Servo-on 11 RD Ready RA 3 (Note 9, 10, 12) Reset Electromagnetic brake interlock 12 MBR Speed selection 1 RA 4 SP1 5 6 Forward rotation start Reverse rotation start ST1 ST2 7 10m max. 10m max

(Note 8) 33 OP Encoder Z-phase pulse (open collector) 1 P15R SD Plate 10m max. (Note 7) 2m max.

STO 3 7 3. 3.2.2 3.2.1 CN8 (16) () 10m (12) CN3 10m DC24V(10) 3 DOCOM (15) CN3 (12) (2) RA1 (34) 2 13 MBR 20 EM2 (13) RA2 9 INP FLS DI1 2 RA3 (11) 15 ALM (14) RLS DI2 12 DOG DI3 19 5 DICOM A 6 LA (10) DC24V () 16 LAR DICOM 10 B () 7 LB 17 LBR (5) 8 LZ Z () USB 18 LZR 1 1 LG MR Configurator2 LEC-MR-J3USB COM () CN5 + 1 4 1 MO1 LG 14 MO2 2 SD 2m (6) LE-CSS(7) SSCNET () CN1A

B 2 2 Plug 3/5(E) port 97 Common Dimensions JSY1000/3000/5000 Series Type 10/Side Ported EX120 EX260 EX250 EX600 EX245 Chart Valve Lead Wire D-sub Flat Ribbon Terminal Block Connector Connecting Base Dimensions: JSY3000 Series External Pilot, Built-in Silencer JJ5SY3-10m (D) (S, R) U D B C6 C8 Stations P, E port entry: D External pilot (Made to Order) U side D side L (10.6) Plug-in Common

When high accuracy is required, design the system so the hysteresis is within the 10m detection distance.

Auto switch type Bore size (mm) Bore size (mm) Standard strokes (mm) Model D-A3, D-A4 D-G3, D-K3 D-B5, D-B6 D-G5, D-K5 D-A5, D-A6 D-F5, D-J5 32 25 to 800 32 BT-06 BA-32 40 25 to 800 40 BT-06 BA-04 BD1-04M 50 25 to 800 50 BT-06 BA-05 BD1-05M CH2E 63 25 to 800 63 BT-08 BA-06 BD1-06M 80 25 to 1000 80 BT-16 BA-08 BD1-08M 100 25 to 1000 100 BT-18 BA-10 BD1-10M 32 BT-06 BAF-32 Note) Refer to