Fittings & Tubing Air Cylinders Rotary Actuators How to Order Clean series 10 11 12 Relief type Vacuum suction type Relief type (with specially treated sliding parts) CXSM, CXSL CXSM, CXSL CXSL Dual rod cylinder 10 CXS M 15 30 Y59A 21 CXS L 15 30 Y59A Number of auto switches Bearing type L M Ball bushing bearing Slide bearing Nil S n 2 pcs. 1 pc. n pcs.
Refer to pages 12-15-3 to 12-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 12-1-4 to 12-1-6 for Precautions on every series. Mounting MHW Warning When using right angle finger tap mounting type, monitor the interference of the bolt with the speed controller. Tighten the bolt from this side .
Refer to pages 12-15-3 to 12-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 12-1-4 to 12-1-6 for Precautions on every series. Mounting MHW Warning When using right angle finger tap mounting type, monitor the interference of the bolt with the speed controller. Tighten the bolt from this side .
19 H 73 88 106 F 93.5 107.5 130.5 O 18.5 19.5 21.5 N 16 15 19 M 13 15 19 K 46 58 68 J 40 46.5 55 H 73 88 106 F 76.5 91 110 Applicable cylinder ML2B25 ML2B32 ML2B40 Applicable cylinder ML2B25 ML2B32 ML2B40 RS Q G MM 16 21.5 24.5 PA Rc 1/8 Rc 1/8 Rc 1/4 LL 28 30.5 37.5 KK 15 16 17.5 O 69 84 102 PP 56 62.5 77 NN 22 26 37.5 PA Rc 1/8 Rc 1/8 Rc 1/4 MM 16 21.5 24.5 LL 28 30.5 37.5 KK 15 16 17.5
Bore size S Stroke ML2B Bore size B Stroke N K M 9 N K M 1 RE A B O 1 H REC O H PP CX NN NN MM MM CY KK LL KK LL 2-PA J J MQQ M 2-PA (Port for operating cylinder) (Port for operating cylinder) F I F RHC (mm) (mm) MK(2) M 30.5 32 41.5 K 46 58 68 J 40 46.5 55 I 76.5 91 110 N 16 15 19 H 73 88 106 F 93.5 107.5 130.5 O 18.5 19.5 21.5 N 16 15 19 M 13 15 19 K 46 58 68 J 40 46.5 55 H 73 88 106 F
21 27 33 37 40 2 2 2 2 2.5 2.5 1 1 1 1 1.5 1.5 5 10 10 10 15 15 11 11 12.5 15 18 21 M8 x 1.25 M8 x 1.25 M8 x 1.25 25, 50 75, 100 125, 150 175, 200 124 106 48 122 90 110 M8 x 1.25 M8 x 1.25 M8 x 1.25 140 120 56 138 100 124 M10 x 1.5 M10 x 1.5 M10 x 1.5 150 130 69 148 110 132 M10 x 1.5 M10 x 1.5 M10 x 1.5 188 160 88 185 140 166 M12 x 1.75 M12 x 1.75 M12 x 1.75 224 190 108 221 170 200 M14 x
Z Y59AZ Solid state switches marked "" are produced upon receipt of order. Note 1) Perpendicular electrical entry is not available for 50 and 63.
MGF40 D-XC79 Machining tapped hole, drilled hole and pin hole additionally MGF63 30, 50, 75, 100 -X MGF100 20Minimum Stroke for Auto Switch Mounting Data (mm) Applicable auto switch No. of auto switches mounted D-Z7 D-Z8 D-Y69 D-Y7V D-Y59 D-Y7 D-Y7W D-Y7BAL D-Y7WV 10 5 10 15 20 1 pc. 15 10 10 15 20 2 pcs.
Refer to pages 12-15-3 to 12-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to page 12-1-4 to 12-1-6 for Precautions on every series. Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.
Refer to pages 12-15-3 to 12-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to page 12-1-4 to 12-1-6 for Precautions on every series. Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.
Example) In case an MGF63-15 specification is required, a spacer of 15mm is installed in the MGF63-30. Therefore, the total length is same as that of 30mm stroke. MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.
Example) In case an MGF63-15 specification is required, a spacer of 15mm is installed in the MGF63-30. Therefore, the total length is same as that of 30mm stroke. MGF 40 MGF 63 30, 50, 75, 100 MGF100 Minimum Strokes for Mounting Auto Switches (mm) Switch type D-Z7, D-Z8 D-Y5, D-Y6, D-Y7 Number of pcs. 10 5 1 pc. 15 10 2 pcs.
Refer to pages 12-15-3 to 12-15-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 12-1-4 to 12-1-6 for Precautions on every series. Warning If a workpiece is hooked onto the attachment, make sure that excessive impact will not be created at the start and the end of the movement.
Guide Suffix: Guide 1 Shaft, Bore Size: 25mm, Port Thread: Rc; Bore 25, 32, M5; Bore 15 Only, Stroke: 300mm, Auto Switch: Y59AZ--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 5M
Guide Suffix: Guide 1 Shaft, Bore Size: 25mm, Port Thread: Rc; Bore 25, 32, M5; Bore 15 Only, Stroke: 300mm, Auto Switch: Y59AZ--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 5M, Number: -
Part Number Description: RETAINING RING (CXSM20) Product Line: A Product Line Description: ACTUATOR Family Code: 457 Family Description: CXS GUIDED CYLINDER Class Code: H1 Part Code: 2 Reference Code: J This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number
Double acting, single rod, Bore size *: 125, 140, 160, Available port threads: Rc, NPT, G, Optional rod boots, Auto switch capable, ASSY, HEAD COVER (CXSM20), ACTUATOR, CXS GUIDED CYLINDER, H1, 20MM CXS PART, .01210 lb, ModelPart numberNo. of bumpersCXS20/25CXS20-34A 287491
Please contact us for the latest version.sales@ocaire.com, ASSY, PISTON ROD (CXSM20-100), ACTUATOR, CXS GUIDED CYLINDER, H1, 20MM CXS PART, .00000 lb, ModelStandard stroke (mm) 1015202530354045506070758090100CXSM200.400.420.440.460.480.4950.510.530.550.5850.620.640.660.700.74
Bore Size: 20mm, Thread: ø6-ø20 Bore: M Thread; ø25,ø32 Bore: Rc 1/8, Stroke: 70mm, Auto Switch: Y59A--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: Z (5m)
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure