SMC Corporation of America
Elite Part Number Search
Search Results "CY1SG20-250BZ-A93V"

Piping: Centralized Piping Type, Bore Size: 15mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 250mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Piping: Centralized Piping Type, Bore Size: 25mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 250mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Piping: Centralized Piping Type, Bore Size: 32mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 250mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Piping: Centralized Piping Type, Bore Size: 40mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 250mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

Piping: G (Centralized Piping Type), Bore Size: 20mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 300mm, Stopper Type: BS ([Shock Absorber/Adjustment Bolt (Metal Ended), Plate A Side; Bumper Bolt (Resin Tipped), Plate B Side or C Side], Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical

Piping: G (Centralized Piping Type), Bore Size: 20mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 300mm, Stopper Type: Bumper Bolt (Resin Tipped), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical

Piping: G (Centralized Piping Type), Bore Size: 20mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 350mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical

Piping: G (Centralized Piping Type), Bore Size: 20mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 800mm, Stopper Type: Bumper Bolt (Resin Tipped), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical

Piping: G (Centralized Piping Type), Bore Size: 20mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 700mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical

Piping: Centralized Piping Type, Bore Size: 20mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 300mm, Stopper Type: [Shock Absorber/Adjustment Bolt (Metal Ended), Plate A Side; Bumper Bolt (Resin Tipped, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Piping: Centralized Piping Type, Bore Size: 20mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 300mm, Stopper Type: Bumper Bolt (Resin Tipped), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Piping: Centralized Piping Type, Bore Size: 20mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 350mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Piping: Centralized Piping Type, Bore Size: 20mm, Port Thread: M Thread: Bore 6-15; Rc: Bore 20-40, Stroke: 700mm, Stopper Type: B [Shock Absorber/Adjustment Bolt (Metal Ended), Mounted on Both Sides], Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Cylinder Joint Type: Magnetic, Guide: [Sliding Guide] Guide Type of Slide Bearing, Table Size Width W(mm): 90, Table Size Height H(mm): 46, Table Surface Treatment: No, Environment: General Purpose, Maximum Load(kg): 12, Piping Format: Centralized piping, Port Screw Type: Rc, Adjuster Option: Dual-end damper bolts (resin tip), Switch Rail: Yes, Specification: Magnet built-in, Auto Switches: A93V

The new style MGP has a shorter guide rod and thinner plate resulting in a weight reduction of up to 17% over the original MGP.  The series is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing

Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: G, Auto Switches: A93V

Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: G, Auto Switches: A93V

Bearing Type: L (Ball Bushing), Bore Size: 50mm, Thread Type: TF (G), Stroke: 250mm, Stroke Adjustment: B (0 to 25), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC9 (Adjustable Stroke, Retraction Type)

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,