/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 522 for power consumption of AC type.
Same side Same side 110C Heat resistant tarpaulin K D-C7 D-C8 D-H7 D-H7W D-H7BAL D-H7NF D-C73C D-C80C D-H7C 15 50+45(n2) 50 10 Max. ambient temperature for rod boot n2 2 15+45( ) (n=2, 4, 6) 15 60+45(n2) 60 10 n2 2 15+50( ) (n=2, 4, 6) 15 65 10 65+50(n2) n2 2 20+50( ) (n=2, 4, 6) D-H7LF 20 65 10 D-B5 D-B6 n2 2 15+50( ) (n=2, 4, 6) 15 75 10 75+55(n2) n2 2 20+50( ) (n=2, 4, 6) D-B59W 20 75
, 50, 63, 80 and 100.) 13 Guide Cylinder Series MGG Construction 20 to 50/MGG #8 !
32, 40, 50, 63, 80 and 100.) 8-21-18 18 Guide Cylinder Series MGG Construction 20 to 50/MGG #8 !
K Note 2) Negative common N Note 3) Coil voltage CE-compliant External pilot R Note 3) Note 5) 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Note 1) Refer to page 381 for power consumption of AC type.
to 500 mm/sec) Rubber bumper: 2 to 30 in/sec (50 to 750 mm/sec) Piston speed Rubber bumper Option (No additional charge on 7/8" and 1 1/4" bore) Lubrication Not required (Pre-lubricated at Factory) Mounting B, C, E, R Note) R mount available on 3/4", 1 1/16", and 1 1/2" only.
D-H7C D-B5, D-B6, D-B59W Approx. HS Approx.
JIS symbol Double acting Minimum Strokes for Auto Switch Mounting Stroke Long stroke (2) (mm) Max stroke (mm) Number of switches Bore size (mm) Standard stroke (1) (mm) Auto switch model 2 1 D-C7/C8 D-B5/B6 D-H7 D-G5/K5 25, 50, 75, 100, 125, 150, 200 201 to 350 20 15mm 10mm 301 to 400 25 301 to 450 32 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 15mm 1500 301 to 800 40 D-B59W 301 to 1200
Coil rated voltage VP7 1 2 3 4 5 6 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC VP4 VQ VQ4 Wiring Specifications VQZ The lead wires are connected to the valve as shown below. Connect each to the power supply side.
55 60 65 70 75 35 40 45 50 55 60 65 70 75 80 D 30 35 40 45 50 55 30 35 40 45 50 55 30 35 40 45 Mounting bolt part no.
D-H7 type On the head side of the bore size 20, 25, 32, 40, 50, 63 D-A9/C7/C8 types On the head side of the bore size 20, 32, 40 D-G5/K5/B59W types On the head side of the bore size 20, 25, 32, 50, 63 D-B5/B6 types On the head side of the bore size 20, 25, 32, 50, 63, 80, 100 and the rod side of the bore size 20, 25, 32 -X Technical Data 373 CG3 Series Minimum Stroke for Auto Switch
14 18 (6.3) B1 A1 5 6 17.7 14.2 A6 B6 B1 A1 10.2 2 1 B3 A3 (5.7) 15 16 11 30.7 45 - 115 I/O No.
(mm) Stroke range (mm) Special cap bolt 32 5 to 50 50 33 60 43 5.5 8 48 56 65 75, 100 60 43 M FV 40 5 to 50 56.5 39.5 66.5 49.5 5.5 8 54 62 72 75, 100 66.5 49.5 FT L B + Stroke A + Stroke 50 10 to 50 58.5 40.5 68.5 50.5 6.6 9 67 76 89 75, 100 68.5 50.5 4 x FD FX FZ Bore size (mm) Stroke range (mm) L L1 M 32 5 to 50 17 38.5 34 75, 100 40 5 to 50 17 38.5 40 75, 100 L1 50 10 to 50 18 43.5 50
LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds the 0.5 to 5.0 set value.
LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds 0.5 to 5.0 the set value.
Since Series CHM does not have an air release valve, release air from components other than the cylinder (e.g. from piping, etc.). 20 + 50 n 2 2 20 65 10 D-H7LF (n = 2, 4, 6 ) D-B5 D-B6 D-G5NTL 15 + 50 n 2 2 15 75 10 2. When operating a cylinder for the first time, be sure to release the air at low pressure.
, 50, 75, 100, 125, 150, 200 MB 40, 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300 Please consult with SMC for strokes which exceed the standard stroke length.
20 100V CE1 PLC D-C73C 5 to 40 24V DC AC DC CE2 D-C80C IC circuit, Relay, PLC 50 24Vor less D-B53,A33 5 to 50 24V DC PLC ML2B 5 to 50 24V DC D-B54 D-A34 D-A44 5 to 25 100V AC ML1C 5 to 12.5 200V AC AC DC 50 Relay, PLC 24Vor less REA D-B64 25 100V AC 12.5 200V AC REC 5 to 40 2 color** D-B59W 24V DC RHC * Use contact protection box when using "D-C7" or "D-C8" type in the following conditions
However, the piston speed at this time should be adjusted to the minimum speed. 15 65 10 (n = 2, 4, 6 ) 65 + 50 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 20 65 10 D-H7LF (n = 2, 4, 6 ) 15 + 50 n 2 2 D-B5 D-B6 15 75 10 (n = 2, 4, 6 ) Mounting 75 + 55 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 Caution D-B59W 20 75 15 (n = 2, 4, 6 ) 1.