Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)]
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option: -
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: -
Cooling Capacity: 030 [2500/3000, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: -
15 15 16 16 20 20 22 22 28 35 The standard stroke for 12 and 16 is 100 st.
/300-A-40. 8-9 8.2.4 HRSH100/150/200/250-W-20/40. 8-10 8.3 Flow Diagram . 8-11 8.3.1 HRSH-A-20/40. 8-11 8.3.2 HRSH-W-20/40. 8-12 8.4 Cooling Capacity . 8-13 8.4.1 HRSH100-A-20/40. 8-13 8.4.2 HRSH150-A-20/40. 8-13 8.4.3 HRSH200-A-20/40. 8-14 8.4.4 HRSH250-A-20/40. 8-14 8.4.5 HRSH300-A-20/40. 8-15 8.4.6 HRSH100-W-20/40. 8-16 8.4.7 HRSH150-W-20/40. 8-16 8.4.8 HRSH200-W-20/40. 8-17 8.4.9 HRSH250
solenoids available) y SUP/EXH block assembly 24 24 stations 20 20 stations *1 Double wiring: 2-position single, double, 3-position, and 4-position valves can be used on all manifold stations.
-W-20/40/46. 8-11 8.4 Cooling capacity . 8-12 HRS Series HRX-OM-S004 Contents 8.4.1 HRS100-A-20/40/46. 8-12 8.4.2 HRS150-A-20/40/46. 8-12 8.4.3 HRS100-W-20/40/46. 8-13 8.4.4 HRS150-W-20/40/46. 8-13 8.5 Pump capacity . 8-14 8.5.1 HRS100/150-A/W-20/40/46. 8-14 8.6 Types of Hazard Labels (HRS--40/46-) . 8-15 8.6.1 Positions of danger warning label . 8-16 8.7 Standards . 8-17 8.8 Sample DoC.
52 : 1 3/4-12 85 : M24 x 1.5 25 : 5/8-11 53 : 1 3/4-5 86 : M26 x 1.5 26 : 5/8-18 54 :1 7/8-12 87 : M30 x 1.5 FEMALE ROD DIAMETER BORE (INCH) A B C MM KK WF 150 (1.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 200 (2) 3/4 1 1/8 3/8 5/8 7/16-20 1 250 (2.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 325 (3.25) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 400 (4) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 22 Air Cylinder Extended Series NCA1 PARTS
52 : 1 3/4-12 85 : M24 x 1.5 25 : 5/8-11 53 : 1 3/4-5 86 : M26 x 1.5 26 : 5/8-18 54 :1 7/8-12 87 : M30 x 1.5 FEMALE ROD DIAMETER BORE (INCH) A B C MM KK WF 150 (1.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 200 (2) 3/4 1 1/8 3/8 5/8 7/16-20 1 250 (2.5) 3/4 1 1/8 3/8 5/8 7/16-20 1 325 (3.25) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 400 (4) 1 1/8 1 1/2 1/2 1 3/4-20 1 3/8 22 Air Cylinder Extended Series NCA1 PARTS
35oC 20 15 10 5 0 0 5 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Fig. 9-18 Cooling Capacity (HRL200-W-40 CH1) HRL Series 9.4 Cooling Capacity 9-17 HRX-OM-X037 Chapter 9 Documents 9.4.13 HRL100/200-W-40 CH2 3.0 2.5 Cooling capacity [kW] Ambienttemperature 45oC or less 2.0 (Max. 1.5 kW) 1.5 Rated 1.0 kW 1.0 0.5 0.0 10 15 20 25 30 35 40 Circulating fluid temperature [oC] Up to
Thermo Chiller, CHILLER, RACK MOUNT, REFRIGERATION TYPE, O72, 64.00000 lb
For rewrse operation mode, in wf|ich the valve stem mo!
For rewrse operation mode, in wf|ich the valve stem mo!
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 010 [1000/1100, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 024 [2000/2400, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DM+U
Cooling Capacity: 018 [1600/1800, (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option: DM+U