filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PC BOARD / HRS012-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb

filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, L/SIDE PANEL (HRS012/018/024), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000

of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Electric Conductiviy Sensor - HRS012

with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Support Bracket HRS012

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: -

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None

Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None

Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJ (B + J)

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: Automatic Water Supply Function

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + G

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: B + G + J + M + T

Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: NPT w/PT-NPT Conversion Fitting Set, Option: High Temp Environment Specs