Cooling Method: Water-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz, Option: w/Automatic Fluid Fill Function
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: M (Applicable to Deionized Water Piping)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: B (w/Earth Leakage Breaker)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: MS (Applicable to Deionized Water Piping + Conforming to CE/UL Standards)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: S (Conforming to CE/UL Standards)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: J (w/Automatic Fluid Fill Function)
(b) OFF ON OFF 63.4% CDT = 100 ms 100 50 100 4.00 10.00 4.00 120 84 120 3000 4000 3000 20 50 20 1 50 60 50 1 50 60 50 1 0.20 0.15 0.20 1 0.20 0.15 0.20 2 20 30 20 2 20 30 20 2 0.10 0.05 0.10 2 0.10 0.05 0.10 (2) (a) PB06 GD2 4.00 [] PB08 PG2 120 [rad/s] PB09 VG2 3000 [rad/s] PB10 VIC 20 [ms] PB29 GD2B 10.00 [] PB30 PG2B 84 [rad/s] PB31 VG2B
-A-20/40HRSH150-W-20/4025 25 Facility water temperature 32C Ambient temperature 32C 20 20 Cooling capacity [kW] Cooling capacity [kW] 15.7 15.7 15 15 Ambient temperature 43C 10 10 Facility water temperature 40C Ambient temperature 45C 5 5 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRSH200-A-20/40HRSH200-W-20/4030 30 Ambient
x Width 925 x Depth 955] HRS150-W -20-A 459 [208] HRS150-A-20
[C] HRS100-W-20/40(60 Hz) HRS100-W-20/40(50 Hz) 14 14 Facility water temperature 32C 12 12 Cooling capacity [kW] Cooling capacity [kW] Facility water temperature 32C 10 10 8 8 6 6 4 4 Facility water temperature 40C Facility water temperature 40C 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [C] Circulating fluid temperature [C] HRS150-A-20/40(50 Hz) HRS150-
Cooling Method: Air-cooled Refrigeration, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz), Option: w/Automatic Fluid Fill Function + Applicable to Deionized Water Piping
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: JM (w/Automatic Fluid Fill Function + Applicable to Deionized Water Piping)
HED Polypropylene skid HEA Model Weight [kg] Dimensions [mm] HRSE012-A-10 35 Height 745 x Width 465 x Depth 575 HRSE018-A-10 HRSE012-A-10-T 42 Height 745 x Width 465 x Depth 620 HRSE018-A-10-T HRSE012-A-20 38 Height 745 x Width 465 x Depth 575 HRSE018-A-20 HRSE024-A-20 HRSE012-A-20-T 45 Height 745 x Width 465 x Depth 620 HRSE018-A-20-T HRSE024-A-20-T HRSE012-A-23 41 Height 790 x Width 470
PV SV 20. Select contact output signal 1 function from the table below with [] key or [] key, and confirm by pressing SEL.
DC24V 2. 20 3. 4. 5. 6. 7. 8.
DC24V 2. 20 3. 4. 5. 6. 7. 8.
Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH090-W-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb
-AN-20), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb