Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 520 ~ 570, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 1000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 35, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 1/2, Control Side Connection Type

Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 520 ~ 570, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 1000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 35, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 1/2, Control Side Connection Type

Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: L (Heavy Duty Auto Drain for Medium Air Pressure)

Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A (Cool Compressed Air Output)

Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: R (Circuit Breaker)

Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A (Cool Compressed Air Output), Option 2: S (Terminal Block Connection)

Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: S (Terminal Block Connection)

Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: Heavy Duty Auto Drain for Medium Air Pressure, Option 2: -

Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: Cool Compressed Air Output, Option 2: -

Size: 4 [0.57m³/min (ANR), 20.13scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: Circuit Breaker

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AIR DRYER, OTHERS, IDF REFRIGERATED DRYER, IDF OTHER SIZE(MISC./OTHER), 48.50169 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AIR DRYER, OTHERS, IDF REFRIGERATED DRYER, IDF OTHER SIZE(MISC./OTHER), 48.50169 lb

IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40°C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Improved corrosion resistance with the use

IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40 C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Improved corrosion resistance with the use

IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40°C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Improved corrosion resistance with the use

cassette VQ1*71 (Cv=0.28) Body ported VQ0*41 (Cv=0.15) VQ1*41 (Cv=0.35) VQ2*41 (Cv=0.9) With both solenoids located at one end VQ flip type With a solenoid located at each end SY3*20 (Cv=0.23) SY5*20 (Cv=0.59) SY7*20 (Cv=0.9) SX3*20 (Cv=0.23) SX5*20 (Cv0.59) SX7*20 (Cv=0.9) Non plug-in valves SX Type 20P/N manifold Compact design With a solenoid located at each end SY3*20 (Cv=0.23) SY5*20

Note 5) Average load coefficient (= ): This coefficient is for averaging the maximum load moment at the time of stopper impact according to service life calculations. 30 30 30 1 3 20 20 20 3.

20 25 25 28 36 24 17.5 25 20 18.5 21 16 16 20 20 25 30 Grooves (Except 12, 16, 20, 25) (mm) Use grooves section a and section b in the figure below of the cylinder body for firmly fixing in the following case.