SMC Corporation of America
Elite Part Number Search
Search Results "IDF8E-20-AT"

Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 1,220 / 1,320, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 2000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 35, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 3/4, Control Side Connection

Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 1,220 / 1,320, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 2000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 35, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 3/4, Control Side Connection

Types: Dryers, Method: [Freezing] Refrigerating type (air-cooling specification), Shape: Standard, Outlet Flow Rate(l/min): 1,220 / 1,320, Outlet Open Air Pressure Dew-Point(°C): 10, Exit Flow Rate Class(l/min): Up to 2000, Supply Side Connection Type: [Rc (R)] Rc, Inlet Air Temperature(°C): 35, Inlet Air Pressure(MPa): 0.7, Supply Side Plumbing Thread Nominal: 3/4, Control Side Connection

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: R (Circuit Breaker)

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A (Cool Compressed Air Output)

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: S (Terminal Block Connection)

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A+K

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: R+T

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: K (Metal Auto Drain Bowl w/Level Gauge; Medium Air Pressure), Option 2: R+T

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: M (Motor Type Auto Drain)

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: T (Terminal Block for Run & Alarm Signal)

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: L (Heavy Duty Auto Drain for Medium Air Pressure)

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: Circuit Breaker

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: A+K, Option 2: -

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: None, Option 2: Terminal Block for Run & Alarm Signal

Size: 8 [1.32m³/min (ANR), 46.62scfm], Voltage: 10 [100VAC (50Hz),100/110VAC (60Hz), Single Phase], Option 1: Heavy Duty Auto Drain for Medium Air Pressure, Option 2: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40 C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Improved corrosion resistance with the use

IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earths ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Improved corrosion resistance with the use of

IDF refrigerated air dryer series, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earths ozone layer. (Medium size series use R22). Series IDF can accommodate an inlet temperature of 40C. Corrosion resistance is improved by using a stainless steel, plate type heat exchanger. Improved corrosion resistance with the use of