Refrigerated air dryer series IDU, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDU provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 55°C.
Refrigerated air dryer series IDU, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDU provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 55°C.
Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 55 C , Refrigerant R134a(HFC), AIR DRYER, OTHERS, IDU DRYER/AFTERCOOLER, IDU OTHER SIZE(MISC./OTHER), 103.61726 lb
Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 55 C , Refrigerant R134a(HFC), AIR DRYER, OTHERS, IDU DRYER/AFTERCOOLER, IDU OTHER SIZE(MISC./OTHER), 50.70632 lb
Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 55C , Refrigerant R134a(HFC), AIR DRYER, OTHERS, IDU DRYER/AFTERCOOLER, IDU OTHER SIZE(MISC./OTHER), 50.70632 lb
Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 55 C , Refrigerant R134a(HFC), REFRIGERATED AIR DRYER, OTHERS, IDU DRYER/AFTERCOOLER, IDU OTHER SIZE(MISC./OTHER), 41.24334 lb
Substantial reduction of installation labor hours , Max. operating pressure: 1.0MPa , Max. operating temperature: IDF 60°C, IDU 80°C, Applicable dryer: IDF1E to 75E, IDU3E to 75E, MOTOR CONTACTOR (IDU), OTHERS, IDU DRYER/AFTERCOOLER, 21, IDU NO SIZE PART, 0.1155 lb
Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 55 C , Refrigerant R134a(HFC), REFRIGERATED AIR DRYER, OTHERS, IDU DRYER/AFTERCOOLER, IDU OTHER SIZE(MISC./OTHER), 28.88055 lb
Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 55 C , Refrigerant R134a(HFC), REFRIGERATED AIR DRYER, OTHERS, IDU DRYER/AFTERCOOLER, IDU OTHER SIZE(MISC./OTHER), 50.6 lb
Improved corrosion resistance with the use of stainless steel, plate type heat exchanger , Protects penumatic equipment from moisture , Rated inlet air temperature: 55C , Refrigerant R134a(HFC) IDU DRYER/AFTERCOOLER. AIR DRYER. OTHERS. IDU OTHER SIZE(MISC./OTHER) . 156.5282 lb.
Mist Separator Series AM Heatless Dryer Series ID Micro Mist Separator Series AMD Application without refrigerated air dryer (Series IDF/IDU) on main line. Series AM + Series ID + Series AMD 14-14-2 14-14-3 2 Air Preparation Equipment Air Preparation Equipment Selection Chart/Guide (4) A standard combination is shown. The end number expresses bore or power supply.
Substantial reduction of installation labor hours , Max. operating pressure: 1.0MPa , Max. operating temperature: IDF 60 C, IDU 80 C, Applicable dryer: IDF1E to 75E, IDU3E to 75E, BYPASS PIPING KIT, OTHERS, IDU DRYER/AFTERCOOLER, 22, IDU NO SIZE KIT/SCCESSORY, 18.48 lb
Substantial reduction of installation labor hours , Max. operating pressure: 1.0MPa , Max. operating temperature: IDF 60 C, IDU 80 C, Applicable dryer: IDF1E to 75E, IDU3E to 75E, BYPASS PIPING KIT, OTHERS, IDU DRYER/AFTERCOOLER, 22, IDU NO SIZE KIT/SCCESSORY, 18.48 lb
Substantial reduction of installation labor hours , Max. operating pressure: 1.0MPa , Max. operating temperature: IDF 60 C, IDU 80 C, Applicable dryer: IDF1E to 75E, IDU3E to 75E, COMPRESSOR KIT (IDU8E-10), OTHERS, IDU DRYER/AFTERCOOLER, 11, IDU OTHER SIZEPART, 0.22 lb
Substantial reduction of installation labor hours , Max. operating pressure: 1.0MPa , Max. operating temperature: IDF 60 C, IDU 80 C, Applicable dryer: IDF1E to 75E, IDU3E to 75E, RIGHT SIDE PANEL FOR IDU8E-10, OTHERS, IDU DRYER/AFTERCOOLER, 11, IDU OTHER SIZEPART, 1.01475 lb
Refrigerated air dryer series IDU, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDU provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 55°C.
Refrigerated air dryer series IDU, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDU provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 55°C.
Refrigerated air dryer series IDU, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDU provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 55°C.
Refrigerated air dryer series IDU, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDU provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 55°C.
Refrigerated air dryer series IDU, in compliance with the Montreal Protocol Regulations, uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22). Series IDU provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 55°C.