-2) n = 2, 3, 4, 5 10 55 35 55 + 55(n-2) n = 2, 3, 4, 5 35 + 30(n-2) n = 2, 3, 4, 5 10 10 + 40(n-2)/2 n = 2, 4, 6, 8 10 10 + 40(n-2)/2 n = 2, 4, 6, 8 10 10 + 30(n-2)/2 n = 2, 4, 6, 8 15 10 + 45(n-2)/2 n = 2, 4, 6, 8 160 10 10 + 55(n-2)/2 n = 2, 4, 6, 8 A5 A6 2 A59W n 15 15 15 10 10 + 55(n-2)/2 n = 2, 4, 6, 8 15 15 + 55(n-2)/2 n = 2, 4, 6, 8 10 100 35 1 1, 2 F5(W)/J5/J59W n F5BAL/F59F
n = 2, 3, 4 60 + 30 (n 2) n = 2, 4, 6, 8 100 + 100 (n 2) n = 2, 3, 4 90 + 100 (n 2) n = 2, 4, 6, 8 65 + 30 (n 2) n = 2, 4, 6, 8 75 + 30 (n 2) n = 2, 4, 6, 8 80 + 30 (n 2) n = 2, 4, 6, 8 85 + 30 (n 2) n = 2, 4, 6, 8 95 + 100 (n 2) n = 2, 4, 6, 8 100 + 100 (n 2) n = 2, 4, 6, 8 105 + 100 (n 2) n = 2, 4, 6, 8 110 + 100 (n 2) n = 2, 4, 6, 8 D-A3 D-G39 D-K39 n (Different sides) n (Same
9 i @2 q r y #0 $0 $2 w A C B A section $1 !2 !2 $6 !0 u @5 !6 @1 !1 $7 o $8 #4 @6 #9 @8 #6 #7 e $4 B section C section #1 #2 !2 100 80 63 50 40 32 80, 100 80, 100 Description Material Note Component Parts No. Description Material Note No.
No. of auto switches mounted 2 Different sides C85 Auto switch model Same side n Different sides 1 Same side C95 D-C7 D-C80 D-H7 D-H7W D-H7BAL D-H7NF D-C73C D-C80C D-H7C 10 50 15 50 + 45 (n 2) n 2 2 15 + 45 ( ) (n = 2, 4, 6) CP95 10 60 15 60 + 45 (n 2) NCM NCA n 2 2 15 + 50 ( ) (n = 2, 4, 6) 10 65 15 65 + 50 (n 2) Dn 2 2 D-B5/B6 D-G5NTL 15 + 50 ( ) (n = 2, 4, 6) 75 10 15 -X 75 + 55
[1] Power supply input terminals, L1, L2: Provide specified power supply to input terminals L1 and L2. [2] Connect the motor input terminal (U, V, W) to the driver power terminal (U, V, W).
sides n = 2, 3, 4 n = 2, 4, 6, 8 n = 2, 4, 6, 8 n = 2, 4, 6, 8 100 + 100 (n 2) 100 + 100 (n 2) n = 4, 6, 8 Same side n = 2, 3, 4 10 1 pc. 90 75 80 35 75 Different sides 80 90 55 75 Same side 80 90 35 + 30 (n 2) 75 + 30 (n 2) 80 + 30 (n 2) 90 + 30 (n 2) Different sides D-A44 n = 2, 3, 4 n = 2, 4, 6, 8 n=2, 4, 6, 8 n = 2, 4, 6, 8 55 + 50 (n 2) 75 + 50 (n 2) 80 + 50 (n 2)
Example) 90-AW30K-03B-1N q w e r t y Series compatible with secondary batteries 90 Material restriction q Symbol Body size Description 30 40 60 w K With backflow function With backflow function + Nil N F Thread type Rc NPT G e + 02 03 04 06 10 1/4 3/8 1/2 3/4 1 r Port size + Nil B Note 2) Note 1) Mounting Without mounting option With bracket With set nut (for panel fitting) a Option t H +
) 5 V, 12 V IC circuit BMP1-032 12 V Relay, PLC 24 V Grommet Yes Diagnostic indication (2-color indication) 5 V, 12 V IC circuit 12 V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z : Manufactured upon receipt of order. 6-13-4 4 Series CP95 ISO/VDMA Cylinder: Standard Type Double Acting w/ End
) 5 V, 12 V IC circuit BMP1-032 12 V Relay, PLC 24 V Grommet Yes Diagnostic indication (2-color indication) 5 V, 12 V IC circuit 12 V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A53 3 m L (Example) A53L 5 m Z (Example) A53Z : Manufactured upon receipt of order. 6-13-4 4 Series CP95 ISO/VDMA Cylinder: Standard Type Double Acting w/ End
Refer to Best Pneumatics No. 2-1 for details. 361 CH2E/CH2F/CH2G/CH2H Series Construction @7 q y i @8 !4 #1 @6 @1 u @0 #0 o w !5 !8 !9 !6 !7 @9 !2 @2 @4 t e !0 CH2G Series !3 @3 r @5 !
Standard stroke range (mm) Long stroke range (mm) Bore (mm) TC GB GA F E AL TB C D B1 ZZ A H H1 I J K KA MM NA P S TA WA WB W WH 30 12 12 12 13 14 14 20 20 2 2 2 2 2 2 3 3 12 14 18 25 30 32 40 50 14 11 11 20 25 32 40 50 63 80 100 8 10 12 16 20 20 25 30 18 22 22 30 35 35 40 40 15.5 13 17 17 19 27 27 32 41 10 (12) 35 5 6 6 8 11 11 13 16 26 31 38 47 58 72 89 M4 X 0.7 Depth 7 5 6 8 10 14 18 18
RX RX RX RX RX RX RX RX (n+2)8 (n+2)9 (n+2)7 (n+2)6 (n+2)5 (n+2)4 (n+2)3 (n+2)2 Point table No. output 3 (PT2) RX(n+2)4 0 0 0 0 0 0 1 0 1 1 0 0 0 0 0 2 0 0 Point table No. output 4 (PT3) RX(n+2)5 1 1 0 0 0 0 0 3 0 0 1 4 0 0 0 0 0 0 Point table No. output 5 (PT4) RX(n+2)6 Point table No. output 6 (PT5) RX(n+2)7 1 1 1 1 1 254 1 1 0 1 255 1 1 1 1 1 1 1 Point table No. output 7 (PT6) RX(n+2)8
RX RX RX RX RX RX RX RX (n+2)8 (n+2)9 (n+2)7 (n+2)6 (n+2)5 (n+2)4 (n+2)3 (n+2)2 Point table No. output 3 (PT2) RX(n+2)4 0 0 0 0 0 0 1 0 1 1 0 0 0 0 0 2 0 0 Point table No. output 4 (PT3) RX(n+2)5 1 1 0 0 0 0 0 3 0 0 1 4 0 0 0 0 0 0 Point table No. output 5 (PT4) RX(n+2)6 Point table No. output 6 (PT5) RX(n+2)7 1 1 1 1 1 254 1 1 0 1 255 1 1 1 1 1 1 1 Point table No. output 7 (PT6) RX(n+2)8
Power supply voltage is 200VAC single phase Trouble OFF ON RA MC Emergency stop MC SK (Note 6) Driver Servo motor Servo amplifier (Note 7) Controller CNP1 MC NFB 1-phase 200 to 230VAC L1 CNP3 (Note 5) U L2 U Motor V L3 V [1] M W N W P1 (Note 1) P2 PE CNP2 P [2] (Note 2) C [3] D Encoder CN2 (Note 3) Encoder cable L11 L21 [1] Provide specified power supply to input terminals L1 and L2. [2]
7) 0V [1] Power supply input terminals, L1 and L2: Specify power supply to input terminals L1 and L2. [2] Connect the motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W).
w-2 From P. 830 w-2 From P. 982 w-2 From P. 922 w-2 From P. 19 CL1 CLS CNA2 MXH-Z Double acting, Single rod Unlocking cams are on the same side as cushion valves.
How to Order S 2 B P H S4 200 LEY 63 A2 w y !0 i o e r t q u !1 !2 !3 !
9 i q @2 e y @3 @0t!6 !7 w !1 !0!3 @1 !4 !2 u !5 o CHK CHN CHM CHS CH2 @2 CHA CHA Related Products 40 DDescription Material Note Parts List Replacement Parts: Seal Kit No. Bore size (mm) Seal kit no.
Minimum Stroke for Auto Switch Mounting n: Number of auto switches [mm] Auto switch model Number of auto switches 32, 40, 45, 50, 56, 63, 67, 80, 85, 100 2 (Different surfaces, Same surface), 1 15 D-M9m D-M9mW n 15 + 40 (n 2) 2 (n = 2, 4, 6, 8) Note) 2 (Different surfaces, Same surface), 1 10 D-M9mV D-M9mWV n 10 + 30 (n 2) 2 (n = 2, 4, 6, 8) Note) 2 (Different surfaces, Same surface), 1