Load (kg) Load (kg) 10 10 30 10 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 REA REB Stroke Stroke Speed REC CY Time Time Stroke P=0.5 MPa,M=10 kg P=0.3 MPa,M=10 kg M=10 kg M=30 kg V=300 mm/s V=100 mm/s CX MQ Model Recommended Speed Controllers Caution RHC RZQ Model Elbow type Straight type In-line type REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F
Load (kg) Load (kg) 10 10 30 10 100 300 Speed (mm/s) Speed (mm/s) Speed (mm/s) 300 300 REA REB Stroke Stroke Speed REC CY Time Time Stroke P=0.5 MPa,M=10 kg P=0.3 MPa,M=10 kg M=10 kg M=30 kg V=300 mm/s V=100 mm/s CX MQ Model Recommended Speed Controllers Caution RHC RZQ Model Elbow type Straight type In-line type REC20 AS2201F-01-06-X214 AS2001F-06-X214 AS2301F-01-06-X214 REC25 AS2201F
No IC circuit P P Y59A Y69A 3 wire (NPN) IC circuit p P P 5V, 12V P.9 Y7P Y7PV IC circuit 3 wire (PNP) p P P Y59B Y69B 12V 2 wire p P P Relay, PLC Solid state switch 24V Y7NW Y7NWV 3 wire (NPN) Grommet Diagnostic indication (2 color indicator) Yes p P P 5V , 12V IC circuit Y7PW Y7PWV P.10 3 wire (PNP) p P P Y7BW Y7BWV 12V p 2 wire P P Lead wire length symbols: 0.5m .
No IC circuit P P Y59A Y69A 3 wire (NPN) IC circuit p P P 5V, 12V P.9 Y7P Y7PV IC circuit 3 wire (PNP) p P P Y59B Y69B 12V 2 wire p P P Relay, PLC Solid state switch 24V Y7NW Y7NWV 3 wire (NPN) Grommet Diagnostic indication (2 color indicator) Yes p P P 5V , 12V IC circuit Y7PW Y7PWV P.10 3 wire (PNP) p P P Y7BW Y7BWV 12V p 2 wire P P Lead wire length symbols: 0.5m .
-ASD330F-01-08 10-ASD230F-M5-06 2.
Approximate response time uptc the tIme of W: Lift force (kgf) P: Vacuum pressure(mmHg) S: Pad area (c m2) adsorption will be worked out by following the equation below. Calculation of suction flow rate OCalculation 01 Ejector/ average suction flow rate. 01 = ( ~ ~'3) 0 max.
RE A B Model Recommended Speed Controller REC Model Elbow type Straight type In-line type CX REC20 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 REC25 AS2201F-01-06-X214 AS2301F-01-06-X214 AS2001F-06-X214 CY REC32 AS2201F-01-06-X214 AS2301F-01-06-X214 AS3001F-08-X214 REC40 AS3201F-02-08-X214 AS3301F-02-08-X214 AS3001F-08-X214 MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way
determination F3 D 1.6 x P WB Inclined operation W + WB WV P PV W + WB WV P PV Allowable driving force table (Fn) (n=1,2,3) Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined (Refer to page 5 for vertical operation.)
D-F9BA No. of auto switches 15 20 25 10 10 5 2 10 15 20 25 5 5 1 Consult P/A for shorter stroke lengths than indicated in the table.
17 43.5 43.9 278 38 9 27 23 241 M10 x 1.25 195 3/8 32 75 62 55 6 M33 x 2.0 25.4 22 52.5 47.3 292 41 11 30 25 251.5 M14 x 1.5 201.5 6.8 to 11.3 3/8 40 50 to 100 EA H EA FA GA A NE Rc P Rc P GA M Effective thread K WH ND H1 MM I C B D E LY 4-LD LH0.2 LT JC Y X JC Y X S + Stroke NF LX LZ LS + Stroke ZZ + Stroke (mm) Bore size (mm) Stroke range (mm) 50 H1 I 11 JC 58 K 75 LD 7 H 11 GA 80 FA 16
determination F3 D 1.6 x P WB Inclined operation W + WB WV P PV W + WB WV P PV Allowable driving force table (Fn) (n=1,2,3) Determination of allowable load weight & pressure F1 = x (W + WB) x 9.8 Horizontal F2 = (W + WB) x 9.8 x (COS + SIN) Inclined (Refer to page 5 for vertical operation.)
Caution REC25 101110-AS2001F-06-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC32 101110-AS3001F-08-X214 10-AS2301F-01-06-X214 10-AS2201F-01-06-X214 REC40 101110-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 2. Speed control is possible with meter-in and meter-out types of speed controllers.
Output Specification: PNP Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter + Front Protection Cover, Option 3: -
Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)
e, axT01&5 I P[ot cotr asrmDty with oprator.
Z + l ZZ + l + Stroke Z + l 80, 100 (mm) Bore size Stroke range Rc, NPT port G port A AL B B1 C D H H1 I J K KA LC LD LH LS LT LX LZ M MM Standard Long stroke GA GB P GA GB P 20 Up to 200 201 to 1500 12 10 (12) 1/8 12 10 (12) M5 x 0.8 18 15.5 34 13 14 8 35 5 26 M4 x 0.7 5 6 4 6 20 45 (53) 3 32 44 3 M8 x 1.25 25 Up to 300 301 to 1500 12 10 (12) 1/8 12.5 10 (12.5) M5 x 0.8 22 19.5 38.5 17
P. 34 P. 34 KQ2L T KQ2T P. 34 KQ2H Use to branch line from female thread in both 90 directions. VMG Branch Y Male run tee Gasket Use to branch line in the same direction from female thread and in 90 direction. KQ2U KQG P. 35 P. 35 KQ2Y P. 36 Use to branch line in the same direction from female thread.
Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.