Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type)
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type)
, http://www.smcworld.com Specifications Model ZSE30A (Vacuum pressure) Rated pressure range Display/Set pressure range Withstand pressure Display/Minimum unit setting Applicable fluid Power supply voltage Current consumption Switch output ZSE30AF (Compound pressure) 100.0 to 100.0 kPa 105.0 to 105.0 kPa 500 kPa 0.1 kPa Air, Non-corrosive gas, Non-flammable gas 12 to 24 VDC 10%, Ripple (p-p
6mm B N7L 1/4 inch D + N NPN1 P PNP1 A NPN2 B PNP2 C NPN1+ D NPN1+ E PNP1+ F PNP1+ 1 L (2 m) 1 (2 m 1 G 1 M SI2 P (psi)1 1NP3 4 1 2kPaMPa -8No.PS-OML0002CN-G / A ZS-38-A1 (M35 L 2 ) B ZS-38-A2 (M35 L 2 ) C ZS-38-A3 (M35 L 2 ) ZS-27-C (M38 L 2 ) + ZS-27-D (M38 L 2 ) ZS-38-3L 3 1 2m ZS-38-4L 4 2 2m ZS-38-3G 3 1 2m ZS-38-4G 4 2 2m ZS-38-5L 3 1m ZS-38-U (10 ) ZS-27-01 4mm
PNP1 A1 A M SI*2 () P (psi)*1 1 2kPaMPa A2 B () M5 M5 M5 B 01 R1/8 N01 NPT1/8 D + 1 L 2m -8No.PS-OMS0006CN-G / A ZS-46-A1 3X8L (2 ) B ZS-46-A2 3X8L (2 ) ZS-46-B + ZS-46-D ZS-46-3L 3 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch ZS-46-N7H 4mm ZS-46-C4L 6mm ZS-46-C6L 1/4 inch ZS-46-N7L -9No.PS-OMS0006CN-G LCD LCD 4 ON/OFF ON/OFF (kPaMPa
Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø6 One-touch Fitting, Elbow Type, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (One-touch Fitting ø6mm, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (One-touch Fitting ø6mm, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: T (w/o Operation Manual, Calibration Certificate)
Bracket mounting inserts found on the standard ISE20B are omitted as well. 25A-ISE20B is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
Bracket mounting inserts found on the standard ISE20B are omitted as well. 25A-ISE20B is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
The ISE20B-S is a digital pressure sensor with all standard features of the ISE20B, while integrating an M12 connection. M12 permits a stable connection for sensor installations outside a cabinet. The sensor has an informative, easy to read 3 screen, 3 color display.
ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.
ISE20B-L-S is a digital pressure sensor with all the standard features of the ISE20B, while integrating an M12 connection and supporting the IO-Link communication protocol. When paired with an IO-Link master, measured values and settings can be accessed from the HMI screen of a PLC.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (One-touch Fitting ø6mm, Elbow Type), Option 1: w/o Lead Wire, Option 2: B (Panel Mount Adapter)
Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: C6L (One-touch Fitting ø6mm, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: K (Operation Manual, Calibration Certificate)